模拟食物液体对树脂基陶瓷水解行为的影响。

Ersan Çelik, Sezgi Cinel Şahin
{"title":"模拟食物液体对树脂基陶瓷水解行为的影响。","authors":"Ersan Çelik, Sezgi Cinel Şahin","doi":"10.11607/ijp.9267","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study aimed to evaluate the hydrolytic behavior of different computer-aided design/computer-aided manufacturing (CAD/CAM) resin matrix ceramics (RMCs) in different food-simulating liquids (FSLs).</p><p><strong>Materials and methods: </strong>Five different CAD/CAM blocks, one from polymer-infiltrated ceramic networks (PICNs; Vita Enamic (EN)) and four from resin-based composites (RBCs; Lava Ultimate (UL), Cerasmart (CER), Brilliant Crios (BR), and Block HC (HC)) were selected. Forty specimens were prepared for each material, and they randomly distributed to each FSLs. The specimens were kept in a desiccator initially, then placed in 5 ml of liquid at 37±1°C for 30 days and weighed at various time intervals. Percentage mass change (Mg%), sorption (SP), percentage of liquid absorbed (SP%), solubility (SL), percentage solubility (SL%), and percentage of liquid absorbed by the polymer matrix (SPpm) water absorption of the specimens were evaluated. Significance was evaluated at p<0.05 levels.</p><p><strong>Results: </strong>Hydrolytic behavior of the materials showed statistical differences in terms of SP, SL, SP%, and SL% values depending on the liquid environment (p=0.001). The highest SP values were obtained from the HC material in saliva, and the lowest values were obtained from the BR in ethanol. The highest SL values were obtained from the CER and EN in heptane, and the lowest values were obtained from the HC in ethanol. However, all results detected in the study remained below the ISO threshold values.</p><p><strong>Conclusions: </strong>All materials tested exhibited clinically acceptable hydrolytic behavior over the time tested. Not only the material content but also many factors can affect the hydrolytic behavior.</p>","PeriodicalId":94232,"journal":{"name":"The International journal of prosthodontics","volume":"0 0","pages":"1-22"},"PeriodicalIF":0.0000,"publicationDate":"2024-12-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effect of Food-Simulating Liquids on Hydrolytic Behavior of Resin Matrix Ceramics.\",\"authors\":\"Ersan Çelik, Sezgi Cinel Şahin\",\"doi\":\"10.11607/ijp.9267\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>This study aimed to evaluate the hydrolytic behavior of different computer-aided design/computer-aided manufacturing (CAD/CAM) resin matrix ceramics (RMCs) in different food-simulating liquids (FSLs).</p><p><strong>Materials and methods: </strong>Five different CAD/CAM blocks, one from polymer-infiltrated ceramic networks (PICNs; Vita Enamic (EN)) and four from resin-based composites (RBCs; Lava Ultimate (UL), Cerasmart (CER), Brilliant Crios (BR), and Block HC (HC)) were selected. Forty specimens were prepared for each material, and they randomly distributed to each FSLs. The specimens were kept in a desiccator initially, then placed in 5 ml of liquid at 37±1°C for 30 days and weighed at various time intervals. Percentage mass change (Mg%), sorption (SP), percentage of liquid absorbed (SP%), solubility (SL), percentage solubility (SL%), and percentage of liquid absorbed by the polymer matrix (SPpm) water absorption of the specimens were evaluated. Significance was evaluated at p<0.05 levels.</p><p><strong>Results: </strong>Hydrolytic behavior of the materials showed statistical differences in terms of SP, SL, SP%, and SL% values depending on the liquid environment (p=0.001). The highest SP values were obtained from the HC material in saliva, and the lowest values were obtained from the BR in ethanol. The highest SL values were obtained from the CER and EN in heptane, and the lowest values were obtained from the HC in ethanol. However, all results detected in the study remained below the ISO threshold values.</p><p><strong>Conclusions: </strong>All materials tested exhibited clinically acceptable hydrolytic behavior over the time tested. Not only the material content but also many factors can affect the hydrolytic behavior.</p>\",\"PeriodicalId\":94232,\"journal\":{\"name\":\"The International journal of prosthodontics\",\"volume\":\"0 0\",\"pages\":\"1-22\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-12-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The International journal of prosthodontics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.11607/ijp.9267\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The International journal of prosthodontics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11607/ijp.9267","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:研究不同计算机辅助设计/计算机辅助制造(CAD/CAM)树脂基陶瓷(RMCs)在不同食物模拟液体(FSLs)中的水解行为。材料和方法:五种不同的CAD/CAM模块,一种来自聚合物渗透陶瓷网络(picn);Vita Enamic (EN))和四种树脂基复合材料(rbc);选择了Lava Ultimate (UL)、Cerasmart (CER)、Brilliant Crios (BR)和Block HC (HC)。每种材料准备40个标本,随机分配到每个fsl。先将标本置于干燥器中,然后置于5ml液体中,在37±1°C下放置30天,并在不同时间间隔称重。对样品的质量变化百分比(Mg%)、吸附性(SP)、液体吸附性百分比(SP%)、溶解度(SL)、溶解度百分比(SL%)和聚合物基质吸附性百分比(SPpm)进行了评价。根据不同的液体环境,材料的水解行为在SP、SL、SP%和SL%值方面显示出统计学差异(p=0.001)。唾液中的HC物质SP值最高,乙醇中的BR SP值最低。正庚烷中的CER和EN的SL值最高,乙醇中的HC的SL值最低。然而,研究中检测到的所有结果仍低于ISO阈值。结论:所有测试的材料在测试时间内都表现出临床可接受的水解行为。影响水解行为的因素不仅有物质含量,还有很多因素。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Effect of Food-Simulating Liquids on Hydrolytic Behavior of Resin Matrix Ceramics.

Purpose: This study aimed to evaluate the hydrolytic behavior of different computer-aided design/computer-aided manufacturing (CAD/CAM) resin matrix ceramics (RMCs) in different food-simulating liquids (FSLs).

Materials and methods: Five different CAD/CAM blocks, one from polymer-infiltrated ceramic networks (PICNs; Vita Enamic (EN)) and four from resin-based composites (RBCs; Lava Ultimate (UL), Cerasmart (CER), Brilliant Crios (BR), and Block HC (HC)) were selected. Forty specimens were prepared for each material, and they randomly distributed to each FSLs. The specimens were kept in a desiccator initially, then placed in 5 ml of liquid at 37±1°C for 30 days and weighed at various time intervals. Percentage mass change (Mg%), sorption (SP), percentage of liquid absorbed (SP%), solubility (SL), percentage solubility (SL%), and percentage of liquid absorbed by the polymer matrix (SPpm) water absorption of the specimens were evaluated. Significance was evaluated at p<0.05 levels.

Results: Hydrolytic behavior of the materials showed statistical differences in terms of SP, SL, SP%, and SL% values depending on the liquid environment (p=0.001). The highest SP values were obtained from the HC material in saliva, and the lowest values were obtained from the BR in ethanol. The highest SL values were obtained from the CER and EN in heptane, and the lowest values were obtained from the HC in ethanol. However, all results detected in the study remained below the ISO threshold values.

Conclusions: All materials tested exhibited clinically acceptable hydrolytic behavior over the time tested. Not only the material content but also many factors can affect the hydrolytic behavior.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Maxillary All-on-6 Treatment Using Zygomatic Implants. Bone Loss Evaluation by CBCT: 3-Year Follow-up. The 'One Customized Abutment One Time' Concept-An Innovative Technique for Optimizing Immediacy and Digital Protocols. Conversion of the Anatomical Crown of a Natural Tooth to an Interim Implant-Retained Restoration for Enhanced Esthetics and Soft Tissue Stability in the Esthetic Zone: A Clinical Report. Long-Term Peri-implant Health and Papilla Formation at Healed Sites with Chairside Provisionalization of Single-Tooth Implants: A Prospective Case Series. Composite Restoration Design Effect During Curing and Chewing.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1