Shayan Khan, Dana Badry Faried Khaled Abdo, Varda Mushtaq, Najeeb Ahmed, Kajal Bai, Fnu Neelam, Maria Malik, Jahanzeb Malik
{"title":"心脏移植患者的心脏植入式电子装置:综合综述。","authors":"Shayan Khan, Dana Badry Faried Khaled Abdo, Varda Mushtaq, Najeeb Ahmed, Kajal Bai, Fnu Neelam, Maria Malik, Jahanzeb Malik","doi":"10.1097/CRD.0000000000000817","DOIUrl":null,"url":null,"abstract":"<p><p>A fraction of patients (approximately 10%) undergoing heart transplantation require permanent pacemaker (PPM) implantation due to sinus node dysfunction or atrioventricular block, occurring either shortly after surgery or later. The incidence of PPM implantation has declined to less than 5% with the introduction of bicaval anastomosis transplantation surgery. Pacing dependency during follow-up varies among recipients. A smaller subset (1.5-3.4%) receives implantable cardioverter-defibrillators (ICDs), but data on their use in transplant recipients are limited, primarily from cohort studies and case series. Sudden cardiac death affects around 10% of transplant recipients, attributed to various nonarrhythmic factors such as acute rejection, late graft failure, and cardiac allograft vasculopathy-induced ischemia. This review offers a comprehensive analysis of the existing data concerning the role of PPMs and ICDs in this population, encompassing leadless PPMs, subcutaneous ICDs, unique considerations, and future directions.</p>","PeriodicalId":9549,"journal":{"name":"Cardiology in Review","volume":" ","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2024-11-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Cardiac Implantable Electronic Devices in Cardiac Transplant Patients: A Comprehensive Review.\",\"authors\":\"Shayan Khan, Dana Badry Faried Khaled Abdo, Varda Mushtaq, Najeeb Ahmed, Kajal Bai, Fnu Neelam, Maria Malik, Jahanzeb Malik\",\"doi\":\"10.1097/CRD.0000000000000817\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A fraction of patients (approximately 10%) undergoing heart transplantation require permanent pacemaker (PPM) implantation due to sinus node dysfunction or atrioventricular block, occurring either shortly after surgery or later. The incidence of PPM implantation has declined to less than 5% with the introduction of bicaval anastomosis transplantation surgery. Pacing dependency during follow-up varies among recipients. A smaller subset (1.5-3.4%) receives implantable cardioverter-defibrillators (ICDs), but data on their use in transplant recipients are limited, primarily from cohort studies and case series. Sudden cardiac death affects around 10% of transplant recipients, attributed to various nonarrhythmic factors such as acute rejection, late graft failure, and cardiac allograft vasculopathy-induced ischemia. This review offers a comprehensive analysis of the existing data concerning the role of PPMs and ICDs in this population, encompassing leadless PPMs, subcutaneous ICDs, unique considerations, and future directions.</p>\",\"PeriodicalId\":9549,\"journal\":{\"name\":\"Cardiology in Review\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2024-11-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Cardiology in Review\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/CRD.0000000000000817\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cardiology in Review","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/CRD.0000000000000817","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
Cardiac Implantable Electronic Devices in Cardiac Transplant Patients: A Comprehensive Review.
A fraction of patients (approximately 10%) undergoing heart transplantation require permanent pacemaker (PPM) implantation due to sinus node dysfunction or atrioventricular block, occurring either shortly after surgery or later. The incidence of PPM implantation has declined to less than 5% with the introduction of bicaval anastomosis transplantation surgery. Pacing dependency during follow-up varies among recipients. A smaller subset (1.5-3.4%) receives implantable cardioverter-defibrillators (ICDs), but data on their use in transplant recipients are limited, primarily from cohort studies and case series. Sudden cardiac death affects around 10% of transplant recipients, attributed to various nonarrhythmic factors such as acute rejection, late graft failure, and cardiac allograft vasculopathy-induced ischemia. This review offers a comprehensive analysis of the existing data concerning the role of PPMs and ICDs in this population, encompassing leadless PPMs, subcutaneous ICDs, unique considerations, and future directions.
期刊介绍:
The mission of Cardiology in Review is to publish reviews on topics of current interest in cardiology that will foster increased understanding of the pathogenesis, diagnosis, clinical course, prevention, and treatment of cardiovascular disorders. Articles of the highest quality are written by authorities in the field and published promptly in a readable format with visual appeal