{"title":"Stryd检测运行过程中质心垂直位移变化的可靠性和准确性。","authors":"Matthew Somma, Michael A Lawrence","doi":"10.1519/JSC.0000000000005038","DOIUrl":null,"url":null,"abstract":"<p><strong>Abstract: </strong>Somma, M and Lawrence, MA. Reliability and accuracy of Stryd to detect changes in vertical displacement of the center of mass while running. J Strength Cond Res XX(X): 000-000, 2024-The purpose of this study was to determine if Stryd can reliably and accurately detect changes in vertical displacement of the center of mass (VCoM) that are produced when cadence was increased by 5 and 10%. A secondary purpose of this investigation was to determine the interlimb reliability of Stryd for VCoM and cadence. Twenty healthy individuals (5 males, 15 females; age: 24.5 ± 1.5 years; mass: 67.1 ± 12.2 kg; height: 1.66 ± 0.01 m) were fitted for motion capture and 2 Stryd devices. After warm-up, subjects ran at a self-selected speed on the treadmill for each condition (self-selected, +5%, and +10% cadence) while VCoM and cadence were collected simultaneously from Stryd and motion capture. Reliability between the Stryd devices on different limbs was excellent for both cadence (intraclass correlation coefficient [ICC] = 0.999, p < 0.001) and VCoM (ICC = 0.993, p < 0.001). Cadence was not significantly different between the Stryd device and motion capture (p = 0.153). Stryd produced significantly (p < 0.001) smaller values for VCoM regardless of condition, with average differences ranging between 4.4 and 4.6 cm. A linear regression revealed that Stryd predicted 50.7% of variation in motion capture VCoM (p < 0.001). Stryd can reliably measure both cadence and VCoM regardless of which limb it is placed on, as indicated by the near-perfect agreement between Stryd devices, and the Stryd device can detect and predict changes in VCoM. However, Stryd consistently underestimates VCoM, which can be corrected by using a linear regression equation.</p>","PeriodicalId":17129,"journal":{"name":"Journal of Strength and Conditioning Research","volume":" ","pages":""},"PeriodicalIF":2.5000,"publicationDate":"2024-12-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Reliability and Accuracy of Stryd to Detect Changes in Vertical Displacement of the Center of Mass While Running.\",\"authors\":\"Matthew Somma, Michael A Lawrence\",\"doi\":\"10.1519/JSC.0000000000005038\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Abstract: </strong>Somma, M and Lawrence, MA. Reliability and accuracy of Stryd to detect changes in vertical displacement of the center of mass while running. J Strength Cond Res XX(X): 000-000, 2024-The purpose of this study was to determine if Stryd can reliably and accurately detect changes in vertical displacement of the center of mass (VCoM) that are produced when cadence was increased by 5 and 10%. A secondary purpose of this investigation was to determine the interlimb reliability of Stryd for VCoM and cadence. Twenty healthy individuals (5 males, 15 females; age: 24.5 ± 1.5 years; mass: 67.1 ± 12.2 kg; height: 1.66 ± 0.01 m) were fitted for motion capture and 2 Stryd devices. After warm-up, subjects ran at a self-selected speed on the treadmill for each condition (self-selected, +5%, and +10% cadence) while VCoM and cadence were collected simultaneously from Stryd and motion capture. Reliability between the Stryd devices on different limbs was excellent for both cadence (intraclass correlation coefficient [ICC] = 0.999, p < 0.001) and VCoM (ICC = 0.993, p < 0.001). Cadence was not significantly different between the Stryd device and motion capture (p = 0.153). Stryd produced significantly (p < 0.001) smaller values for VCoM regardless of condition, with average differences ranging between 4.4 and 4.6 cm. A linear regression revealed that Stryd predicted 50.7% of variation in motion capture VCoM (p < 0.001). Stryd can reliably measure both cadence and VCoM regardless of which limb it is placed on, as indicated by the near-perfect agreement between Stryd devices, and the Stryd device can detect and predict changes in VCoM. However, Stryd consistently underestimates VCoM, which can be corrected by using a linear regression equation.</p>\",\"PeriodicalId\":17129,\"journal\":{\"name\":\"Journal of Strength and Conditioning Research\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.5000,\"publicationDate\":\"2024-12-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Strength and Conditioning Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1519/JSC.0000000000005038\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"SPORT SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Strength and Conditioning Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1519/JSC.0000000000005038","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"SPORT SCIENCES","Score":null,"Total":0}
引用次数: 0
摘要
摘要:Somma, M和Lawrence, MA。Stryd检测运行过程中质心垂直位移变化的可靠性和准确性。[J] Strength Cond Res XX(X): 000-000, 2024-本研究的目的是确定Stryd是否能够可靠准确地检测出当节奏增加5%和10%时所产生的质心垂直位移(VCoM)的变化。本研究的第二个目的是确定Stryd对VCoM和节奏的肢体间可靠性。健康个体20人(男性5人,女性15人;年龄:24.5±1.5岁;质量:67.1±12.2 kg;身高:1.66±0.01 m),配有动作捕捉装置和2个Stryd装置。热身后,受试者在跑步机上以自选速度(自选、+5%和+10%节奏)跑步,同时从Stryd和动作捕捉中收集VCoM和节奏。Stryd装置在不同肢体上的音速(类内相关系数[ICC] = 0.999, p < 0.001)和VCoM (ICC = 0.993, p < 0.001)的可靠性都很好。Stryd设备和动作捕捉之间的节奏无显著差异(p = 0.153)。无论条件如何,Stryd产生的VCoM值显著(p < 0.001)较小,平均差异在4.4至4.6 cm之间。线性回归显示Stryd预测了50.7%的运动捕捉VCoM变异(p < 0.001)。Stryd可以可靠地测量节奏和VCoM,无论它被放置在哪个肢体上,正如Stryd设备之间近乎完美的一致性所表明的那样,Stryd设备可以检测和预测VCoM的变化。然而,Stryd一直低估了VCoM,这可以通过使用线性回归方程来纠正。
Reliability and Accuracy of Stryd to Detect Changes in Vertical Displacement of the Center of Mass While Running.
Abstract: Somma, M and Lawrence, MA. Reliability and accuracy of Stryd to detect changes in vertical displacement of the center of mass while running. J Strength Cond Res XX(X): 000-000, 2024-The purpose of this study was to determine if Stryd can reliably and accurately detect changes in vertical displacement of the center of mass (VCoM) that are produced when cadence was increased by 5 and 10%. A secondary purpose of this investigation was to determine the interlimb reliability of Stryd for VCoM and cadence. Twenty healthy individuals (5 males, 15 females; age: 24.5 ± 1.5 years; mass: 67.1 ± 12.2 kg; height: 1.66 ± 0.01 m) were fitted for motion capture and 2 Stryd devices. After warm-up, subjects ran at a self-selected speed on the treadmill for each condition (self-selected, +5%, and +10% cadence) while VCoM and cadence were collected simultaneously from Stryd and motion capture. Reliability between the Stryd devices on different limbs was excellent for both cadence (intraclass correlation coefficient [ICC] = 0.999, p < 0.001) and VCoM (ICC = 0.993, p < 0.001). Cadence was not significantly different between the Stryd device and motion capture (p = 0.153). Stryd produced significantly (p < 0.001) smaller values for VCoM regardless of condition, with average differences ranging between 4.4 and 4.6 cm. A linear regression revealed that Stryd predicted 50.7% of variation in motion capture VCoM (p < 0.001). Stryd can reliably measure both cadence and VCoM regardless of which limb it is placed on, as indicated by the near-perfect agreement between Stryd devices, and the Stryd device can detect and predict changes in VCoM. However, Stryd consistently underestimates VCoM, which can be corrected by using a linear regression equation.
期刊介绍:
The editorial mission of The Journal of Strength and Conditioning Research (JSCR) is to advance the knowledge about strength and conditioning through research. A unique aspect of this journal is that it includes recommendations for the practical use of research findings. While the journal name identifies strength and conditioning as separate entities, strength is considered a part of conditioning. This journal wishes to promote the publication of peer-reviewed manuscripts which add to our understanding of conditioning and sport through applied exercise science.