Grace Keane, Rob van Rooij, Marnix Lam, Arthur Braat, Maarten Smits, Hugo de Jong
{"title":"99mTc存在下90Y弱应力SPECT图像质量评价:同日放射栓塞的技术视角。","authors":"Grace Keane, Rob van Rooij, Marnix Lam, Arthur Braat, Maarten Smits, Hugo de Jong","doi":"10.3390/curroncol31120554","DOIUrl":null,"url":null,"abstract":"<p><p>In same-day radioembolization, 99mTc-MAA SPECT/CT, 90Y radioembolization, and post-treatment 90Y SPECT/CT procedures are conducted on the same-day, resulting in a dual-isotope environment of 90Y and 99mTc during post-treatment imaging. This study aimed to quantify the impact of 99mTc on 90Y bremsstrahlung-SPECT/CT image quality and to establish an optimised imaging protocol for both clinical practice, and with advanced reconstruction techniques. Utilising a NEMA IQ phantom, contrast recovery coefficients (CRCs) were measured to evaluate the 90Y image quality degradation caused by 99mTc. SPECT/CT scans of 90Y-only and 90Y with varying amounts of 99mTc were conducted using a standard protocol (90-120 keV energy window, high-energy collimator) and various dual-isotope protocols. The standard protocol resulted in a marked CRC reduction, with the largest sphere's CRC decreasing from 0.21 (90Y-only) to 0.05 when 99mTc activity was 5% of 90Y. For an optimised protocol (160-200 keV energy window, high-energy collimator) CRC values were 0.16 for 90Y-only and 0.15 for 90Y+99mTc. The highest CRC values were achieved with an advanced Monte Carlo-based reconstruction, showing 0.58 for 90Y-only and 0.46 for 90Y+99mTc. Image quality degradation was noted in dual-isotope settings even when using an optimised protocol. Advanced reconstruction techniques markedly improved post-treatment image quality.</p>","PeriodicalId":11012,"journal":{"name":"Current oncology","volume":"31 12","pages":"7511-7522"},"PeriodicalIF":2.8000,"publicationDate":"2024-11-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11674725/pdf/","citationCount":"0","resultStr":"{\"title\":\"An Evaluation of 90Y Bremsstrahlung SPECT Image Quality in the Presence of 99mTc: A Technical Perspective on Same-Day Radioembolization.\",\"authors\":\"Grace Keane, Rob van Rooij, Marnix Lam, Arthur Braat, Maarten Smits, Hugo de Jong\",\"doi\":\"10.3390/curroncol31120554\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>In same-day radioembolization, 99mTc-MAA SPECT/CT, 90Y radioembolization, and post-treatment 90Y SPECT/CT procedures are conducted on the same-day, resulting in a dual-isotope environment of 90Y and 99mTc during post-treatment imaging. This study aimed to quantify the impact of 99mTc on 90Y bremsstrahlung-SPECT/CT image quality and to establish an optimised imaging protocol for both clinical practice, and with advanced reconstruction techniques. Utilising a NEMA IQ phantom, contrast recovery coefficients (CRCs) were measured to evaluate the 90Y image quality degradation caused by 99mTc. SPECT/CT scans of 90Y-only and 90Y with varying amounts of 99mTc were conducted using a standard protocol (90-120 keV energy window, high-energy collimator) and various dual-isotope protocols. The standard protocol resulted in a marked CRC reduction, with the largest sphere's CRC decreasing from 0.21 (90Y-only) to 0.05 when 99mTc activity was 5% of 90Y. For an optimised protocol (160-200 keV energy window, high-energy collimator) CRC values were 0.16 for 90Y-only and 0.15 for 90Y+99mTc. The highest CRC values were achieved with an advanced Monte Carlo-based reconstruction, showing 0.58 for 90Y-only and 0.46 for 90Y+99mTc. Image quality degradation was noted in dual-isotope settings even when using an optimised protocol. Advanced reconstruction techniques markedly improved post-treatment image quality.</p>\",\"PeriodicalId\":11012,\"journal\":{\"name\":\"Current oncology\",\"volume\":\"31 12\",\"pages\":\"7511-7522\"},\"PeriodicalIF\":2.8000,\"publicationDate\":\"2024-11-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11674725/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Current oncology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3390/curroncol31120554\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ONCOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current oncology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3390/curroncol31120554","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ONCOLOGY","Score":null,"Total":0}
引用次数: 0
摘要
当日放射栓塞,99mTc- maa SPECT/CT、90Y放射栓塞、治疗后90Y SPECT/CT在同一天进行,导致治疗后成像90Y和99mTc双同位素环境。本研究旨在量化99mTc对90Y形变spect /CT图像质量的影响,并为临床实践和先进的重建技术建立优化的成像方案。利用NEMA IQ模体,测量对比度恢复系数(crc)以评估99mTc引起的90Y图像质量下降。使用标准方案(90-120 keV能量窗,高能准直器)和各种双同位素方案对90Y-only和90Y进行不同99mTc量的SPECT/CT扫描。标准方案导致CRC显著降低,当99mTc活性为90Y的5%时,最大球体的CRC从0.21(仅90Y)降至0.05。对于优化的协议(160-200 keV能量窗口,高能准直器),仅90Y的CRC值为0.16,90Y+99mTc的CRC值为0.15。先进的蒙特卡罗重建获得了最高的CRC值,仅90Y为0.58,90Y+99mTc为0.46。在双同位素设置中,即使使用优化的协议,图像质量也会下降。先进的重建技术显著提高了处理后的图像质量。
An Evaluation of 90Y Bremsstrahlung SPECT Image Quality in the Presence of 99mTc: A Technical Perspective on Same-Day Radioembolization.
In same-day radioembolization, 99mTc-MAA SPECT/CT, 90Y radioembolization, and post-treatment 90Y SPECT/CT procedures are conducted on the same-day, resulting in a dual-isotope environment of 90Y and 99mTc during post-treatment imaging. This study aimed to quantify the impact of 99mTc on 90Y bremsstrahlung-SPECT/CT image quality and to establish an optimised imaging protocol for both clinical practice, and with advanced reconstruction techniques. Utilising a NEMA IQ phantom, contrast recovery coefficients (CRCs) were measured to evaluate the 90Y image quality degradation caused by 99mTc. SPECT/CT scans of 90Y-only and 90Y with varying amounts of 99mTc were conducted using a standard protocol (90-120 keV energy window, high-energy collimator) and various dual-isotope protocols. The standard protocol resulted in a marked CRC reduction, with the largest sphere's CRC decreasing from 0.21 (90Y-only) to 0.05 when 99mTc activity was 5% of 90Y. For an optimised protocol (160-200 keV energy window, high-energy collimator) CRC values were 0.16 for 90Y-only and 0.15 for 90Y+99mTc. The highest CRC values were achieved with an advanced Monte Carlo-based reconstruction, showing 0.58 for 90Y-only and 0.46 for 90Y+99mTc. Image quality degradation was noted in dual-isotope settings even when using an optimised protocol. Advanced reconstruction techniques markedly improved post-treatment image quality.
期刊介绍:
Current Oncology is a peer-reviewed, Canadian-based and internationally respected journal. Current Oncology represents a multidisciplinary medium encompassing health care workers in the field of cancer therapy in Canada to report upon and to review progress in the management of this disease.
We encourage submissions from all fields of cancer medicine, including radiation oncology, surgical oncology, medical oncology, pediatric oncology, pathology, and cancer rehabilitation and survivorship. Articles published in the journal typically contain information that is relevant directly to clinical oncology practice, and have clear potential for application to the current or future practice of cancer medicine.