心脏移植术后早期起搏器依赖与永久性起搏器植入、移植物失败和死亡率相关。

IF 2.4 4区 医学 Q2 CARDIAC & CARDIOVASCULAR SYSTEMS Journal of Cardiovascular Development and Disease Pub Date : 2024-12-08 DOI:10.3390/jcdd11120394
Fabrice F Darche, Karsten M Heil, Rasmus Rivinius, Matthias Helmschrott, Philipp Ehlermann, Norbert Frey, Ann-Kathrin Rahm
{"title":"心脏移植术后早期起搏器依赖与永久性起搏器植入、移植物失败和死亡率相关。","authors":"Fabrice F Darche, Karsten M Heil, Rasmus Rivinius, Matthias Helmschrott, Philipp Ehlermann, Norbert Frey, Ann-Kathrin Rahm","doi":"10.3390/jcdd11120394","DOIUrl":null,"url":null,"abstract":"<p><strong>Aims: </strong>Patients after heart transplantation (HTX) often experience post-transplant bradycardia, but little is known about the outcomes of early pacemaker dependency after HTX. We compared post-transplant mortality, graft failure, and the requirement for the permanent pacemaker implantation of patients with and without early pacemaker dependency after HTX.</p><p><strong>Methods: </strong>We screened all adult patients for early pacemaker dependency after HTX (defined as immediately after surgery) who underwent HTX at Heidelberg Heart Center between 1989 and 2022. Patients were stratified by diagnosis and type of early pacemaker dependency after HTX (sinoatrial or atrioventricular conduction disturbance).</p><p><strong>Results: </strong>A total of 127 of 699 HTX recipients (18.2%) had early pacemaker dependency after HTX, including 52 patients with sinoatrial conduction disturbances (40.9%) and 75 patients with atrioventricular conduction disturbances (59.1%). Patients with early pacemaker dependency after HTX showed both increased 1-year overall mortality after HTX (55.9% vs. 15.2%, <i>p</i> < 0.001) and higher mortality due to graft failure (25.2% vs. 4.2%, <i>p</i> < 0.001). Multivariate analysis revealed early pacemaker dependency after HTX (HR: 5.226, 95% CI: 3.738-7.304, <i>p</i> < 0.001) as an independent risk factor for 1-year mortality after HTX. Patients with early pacemaker dependency after HTX had a higher rate of 30-day (7.1% vs. 0.4%, <i>p</i> < 0.001) and 1-year (11.8% vs. 0.5%, <i>p</i> < 0.001) permanent pacemaker implantation after HTX compared to patients without early pacemaker dependency after HTX.</p><p><strong>Conclusions: </strong>Patients with early pacemaker dependency after HTX had a significantly higher rate of post-transplant mortality, graft failure, and the requirement for permanent pacemaker implantation.</p>","PeriodicalId":15197,"journal":{"name":"Journal of Cardiovascular Development and Disease","volume":"11 12","pages":""},"PeriodicalIF":2.4000,"publicationDate":"2024-12-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11679924/pdf/","citationCount":"0","resultStr":"{\"title\":\"Early Pacemaker Dependency After Heart Transplantation Is Associated with Permanent Pacemaker Implantation, Graft Failure and Mortality.\",\"authors\":\"Fabrice F Darche, Karsten M Heil, Rasmus Rivinius, Matthias Helmschrott, Philipp Ehlermann, Norbert Frey, Ann-Kathrin Rahm\",\"doi\":\"10.3390/jcdd11120394\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Aims: </strong>Patients after heart transplantation (HTX) often experience post-transplant bradycardia, but little is known about the outcomes of early pacemaker dependency after HTX. We compared post-transplant mortality, graft failure, and the requirement for the permanent pacemaker implantation of patients with and without early pacemaker dependency after HTX.</p><p><strong>Methods: </strong>We screened all adult patients for early pacemaker dependency after HTX (defined as immediately after surgery) who underwent HTX at Heidelberg Heart Center between 1989 and 2022. Patients were stratified by diagnosis and type of early pacemaker dependency after HTX (sinoatrial or atrioventricular conduction disturbance).</p><p><strong>Results: </strong>A total of 127 of 699 HTX recipients (18.2%) had early pacemaker dependency after HTX, including 52 patients with sinoatrial conduction disturbances (40.9%) and 75 patients with atrioventricular conduction disturbances (59.1%). Patients with early pacemaker dependency after HTX showed both increased 1-year overall mortality after HTX (55.9% vs. 15.2%, <i>p</i> < 0.001) and higher mortality due to graft failure (25.2% vs. 4.2%, <i>p</i> < 0.001). Multivariate analysis revealed early pacemaker dependency after HTX (HR: 5.226, 95% CI: 3.738-7.304, <i>p</i> < 0.001) as an independent risk factor for 1-year mortality after HTX. Patients with early pacemaker dependency after HTX had a higher rate of 30-day (7.1% vs. 0.4%, <i>p</i> < 0.001) and 1-year (11.8% vs. 0.5%, <i>p</i> < 0.001) permanent pacemaker implantation after HTX compared to patients without early pacemaker dependency after HTX.</p><p><strong>Conclusions: </strong>Patients with early pacemaker dependency after HTX had a significantly higher rate of post-transplant mortality, graft failure, and the requirement for permanent pacemaker implantation.</p>\",\"PeriodicalId\":15197,\"journal\":{\"name\":\"Journal of Cardiovascular Development and Disease\",\"volume\":\"11 12\",\"pages\":\"\"},\"PeriodicalIF\":2.4000,\"publicationDate\":\"2024-12-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11679924/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Cardiovascular Development and Disease\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3390/jcdd11120394\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Cardiovascular Development and Disease","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3390/jcdd11120394","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

目的:心脏移植术后患者经常出现移植后心动过缓,但对心脏移植术后早期起搏器依赖的结果知之甚少。我们比较了HTX术后早期和非早期起搏器依赖患者的移植后死亡率、移植失败和永久起搏器植入需求。方法:我们筛选了1989年至2022年间在海德堡心脏中心接受HTX手术的所有成年患者在HTX术后早期起搏器依赖(定义为术后立即)。根据HTX(窦房或房室传导障碍)后早期起搏器依赖的诊断和类型对患者进行分层。结果:699例HTX受者中127例(18.2%)出现HTX术后早期起搏器依赖,其中窦房传导障碍52例(40.9%),房室传导障碍75例(59.1%)。HTX术后早期起搏器依赖患者显示HTX术后1年总死亡率增加(55.9% vs. 15.2%, p < 0.001),移植物衰竭死亡率增加(25.2% vs. 4.2%, p < 0.001)。多因素分析显示,HTX术后早期起搏器依赖(HR: 5.226, 95% CI: 3.738-7.304, p < 0.001)是HTX术后1年死亡率的独立危险因素。HTX术后早期起搏器依赖患者的30天永久性起搏器植入率(7.1% vs. 0.4%, p < 0.001)和1年永久性起搏器植入率(11.8% vs. 0.5%, p < 0.001)均高于HTX术后无早期起搏器依赖患者。结论:HTX术后早期起搏器依赖患者的移植后死亡率、移植物失败率和永久植入起搏器的需求明显高于其他患者。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Early Pacemaker Dependency After Heart Transplantation Is Associated with Permanent Pacemaker Implantation, Graft Failure and Mortality.

Aims: Patients after heart transplantation (HTX) often experience post-transplant bradycardia, but little is known about the outcomes of early pacemaker dependency after HTX. We compared post-transplant mortality, graft failure, and the requirement for the permanent pacemaker implantation of patients with and without early pacemaker dependency after HTX.

Methods: We screened all adult patients for early pacemaker dependency after HTX (defined as immediately after surgery) who underwent HTX at Heidelberg Heart Center between 1989 and 2022. Patients were stratified by diagnosis and type of early pacemaker dependency after HTX (sinoatrial or atrioventricular conduction disturbance).

Results: A total of 127 of 699 HTX recipients (18.2%) had early pacemaker dependency after HTX, including 52 patients with sinoatrial conduction disturbances (40.9%) and 75 patients with atrioventricular conduction disturbances (59.1%). Patients with early pacemaker dependency after HTX showed both increased 1-year overall mortality after HTX (55.9% vs. 15.2%, p < 0.001) and higher mortality due to graft failure (25.2% vs. 4.2%, p < 0.001). Multivariate analysis revealed early pacemaker dependency after HTX (HR: 5.226, 95% CI: 3.738-7.304, p < 0.001) as an independent risk factor for 1-year mortality after HTX. Patients with early pacemaker dependency after HTX had a higher rate of 30-day (7.1% vs. 0.4%, p < 0.001) and 1-year (11.8% vs. 0.5%, p < 0.001) permanent pacemaker implantation after HTX compared to patients without early pacemaker dependency after HTX.

Conclusions: Patients with early pacemaker dependency after HTX had a significantly higher rate of post-transplant mortality, graft failure, and the requirement for permanent pacemaker implantation.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Cardiovascular Development and Disease
Journal of Cardiovascular Development and Disease CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
2.60
自引率
12.50%
发文量
381
期刊最新文献
Spinal Cord Stimulation for Refractory Angina Pectoris: Current Status and Future Perspectives, a Narrative Review. Longitudinal Outcomes of Patients with Aortic Stenosis Stratified by Sex: An Asian Perspective. Direct Axillary Artery Cannulation as Standard Perfusion Strategy in Minimally Invasive Coronary Artery Bypass Grafting. Interindividual Variability Response to Resistance and High-Intensity Interval Training on Blood Pressure Reduction in Hypertensive Older Adults. Rapid Improvement in Cardiac Damage Predicts Better Prognosis After Transcatheter Aortic Valve Replacement.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1