迈向精确的生物相容性:重新思考生物医学应用中可生物降解镁合金的细胞毒性评价。

IF 5 3区 医学 Q1 ENGINEERING, BIOMEDICAL Journal of Functional Biomaterials Pub Date : 2024-12-18 DOI:10.3390/jfb15120382
Angela De Luca, Roberta Ruggiero, Aurora Cordaro, Benedetta Marrelli, Lavinia Raimondi, Viviana Costa, Daniele Bellavia, Elisabetta Aiello, Matteo Pavarini, Antonio Piccininni, Marco Tatullo, Elisa Boanini, Francesco Paduano, Gianluca Giavaresi
{"title":"迈向精确的生物相容性:重新思考生物医学应用中可生物降解镁合金的细胞毒性评价。","authors":"Angela De Luca, Roberta Ruggiero, Aurora Cordaro, Benedetta Marrelli, Lavinia Raimondi, Viviana Costa, Daniele Bellavia, Elisabetta Aiello, Matteo Pavarini, Antonio Piccininni, Marco Tatullo, Elisa Boanini, Francesco Paduano, Gianluca Giavaresi","doi":"10.3390/jfb15120382","DOIUrl":null,"url":null,"abstract":"<p><p>Magnesium and its alloys represent promising candidates for biomedical implants due to their biodegradability and mechanical properties, which are similar to natural bone. However, their rapid degradation process characterized by dynamic pH fluctuations and significant hydrogen gas evolution during biocorrosion adversely affects both in vitro and in vivo assessments. While the ISO 10993-5 and 12 standards provide guidelines for evaluating the in vitro biocompatibility of biodegradable materials, they also introduce testing variability conditions that yield inconsistent results. To address these inherent characteristics of Mg alloys, developing improved methods that accurately simulate the physiological environment for in vitro biocompatibility testing is essential. This study introduces two novel extraction approaches for evaluating Mg alloys: a buffered solution utilizing PBS/DMEM with quaternary dilutions and a modified ISO standard protocol employing decuple dilution of conventional unbuffered extracts. The present findings establish that controlled optimization of extraction conditions, specifically buffer composition and dilution parameters, enables reliable in vitro cytotoxicity assessment of Mg alloys, providing a robust methodology that advances the preclinical evaluation of these promising biodegradable materials.</p>","PeriodicalId":15767,"journal":{"name":"Journal of Functional Biomaterials","volume":"15 12","pages":""},"PeriodicalIF":5.0000,"publicationDate":"2024-12-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11678253/pdf/","citationCount":"0","resultStr":"{\"title\":\"Towards Accurate Biocompatibility: Rethinking Cytotoxicity Evaluation for Biodegradable Magnesium Alloys in Biomedical Applications.\",\"authors\":\"Angela De Luca, Roberta Ruggiero, Aurora Cordaro, Benedetta Marrelli, Lavinia Raimondi, Viviana Costa, Daniele Bellavia, Elisabetta Aiello, Matteo Pavarini, Antonio Piccininni, Marco Tatullo, Elisa Boanini, Francesco Paduano, Gianluca Giavaresi\",\"doi\":\"10.3390/jfb15120382\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Magnesium and its alloys represent promising candidates for biomedical implants due to their biodegradability and mechanical properties, which are similar to natural bone. However, their rapid degradation process characterized by dynamic pH fluctuations and significant hydrogen gas evolution during biocorrosion adversely affects both in vitro and in vivo assessments. While the ISO 10993-5 and 12 standards provide guidelines for evaluating the in vitro biocompatibility of biodegradable materials, they also introduce testing variability conditions that yield inconsistent results. To address these inherent characteristics of Mg alloys, developing improved methods that accurately simulate the physiological environment for in vitro biocompatibility testing is essential. This study introduces two novel extraction approaches for evaluating Mg alloys: a buffered solution utilizing PBS/DMEM with quaternary dilutions and a modified ISO standard protocol employing decuple dilution of conventional unbuffered extracts. The present findings establish that controlled optimization of extraction conditions, specifically buffer composition and dilution parameters, enables reliable in vitro cytotoxicity assessment of Mg alloys, providing a robust methodology that advances the preclinical evaluation of these promising biodegradable materials.</p>\",\"PeriodicalId\":15767,\"journal\":{\"name\":\"Journal of Functional Biomaterials\",\"volume\":\"15 12\",\"pages\":\"\"},\"PeriodicalIF\":5.0000,\"publicationDate\":\"2024-12-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11678253/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Functional Biomaterials\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.3390/jfb15120382\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Functional Biomaterials","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/jfb15120382","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

镁及其合金具有生物可降解性和与天然骨相似的机械性能,是生物医学植入物的理想候选材料。然而,它们在生物腐蚀过程中以动态pH波动和大量氢气释放为特征的快速降解过程对体外和体内评估都有不利影响。虽然ISO 10993-5和12标准提供了评估可生物降解材料体外生物相容性的指南,但它们也引入了产生不一致结果的测试可变性条件。为了解决镁合金的这些固有特性,开发改进的方法来准确模拟体外生物相容性测试的生理环境是必不可少的。本研究介绍了两种评估镁合金的新提取方法:利用PBS/DMEM四倍稀释的缓冲溶液和采用传统非缓冲提取物十倍稀释的改进ISO标准方案。目前的研究结果表明,控制提取条件的优化,特别是缓冲液的组成和稀释参数,能够可靠地进行镁合金的体外细胞毒性评估,为这些有前途的可生物降解材料的临床前评估提供了一种强大的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Towards Accurate Biocompatibility: Rethinking Cytotoxicity Evaluation for Biodegradable Magnesium Alloys in Biomedical Applications.

Magnesium and its alloys represent promising candidates for biomedical implants due to their biodegradability and mechanical properties, which are similar to natural bone. However, their rapid degradation process characterized by dynamic pH fluctuations and significant hydrogen gas evolution during biocorrosion adversely affects both in vitro and in vivo assessments. While the ISO 10993-5 and 12 standards provide guidelines for evaluating the in vitro biocompatibility of biodegradable materials, they also introduce testing variability conditions that yield inconsistent results. To address these inherent characteristics of Mg alloys, developing improved methods that accurately simulate the physiological environment for in vitro biocompatibility testing is essential. This study introduces two novel extraction approaches for evaluating Mg alloys: a buffered solution utilizing PBS/DMEM with quaternary dilutions and a modified ISO standard protocol employing decuple dilution of conventional unbuffered extracts. The present findings establish that controlled optimization of extraction conditions, specifically buffer composition and dilution parameters, enables reliable in vitro cytotoxicity assessment of Mg alloys, providing a robust methodology that advances the preclinical evaluation of these promising biodegradable materials.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Functional Biomaterials
Journal of Functional Biomaterials Engineering-Biomedical Engineering
CiteScore
4.60
自引率
4.20%
发文量
226
审稿时长
11 weeks
期刊介绍: Journal of Functional Biomaterials (JFB, ISSN 2079-4983) is an international and interdisciplinary scientific journal that publishes regular research papers (articles), reviews and short communications about applications of materials for biomedical use. JFB covers subjects from chemistry, pharmacy, biology, physics over to engineering. The journal focuses on the preparation, performance and use of functional biomaterials in biomedical devices and their behaviour in physiological environments. Our aim is to encourage scientists to publish their results in as much detail as possible. Therefore, there is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced. Several topical special issues will be published. Scope: adhesion, adsorption, biocompatibility, biohybrid materials, bio-inert materials, biomaterials, biomedical devices, biomimetic materials, bone repair, cardiovascular devices, ceramics, composite materials, dental implants, dental materials, drug delivery systems, functional biopolymers, glasses, hyper branched polymers, molecularly imprinted polymers (MIPs), nanomedicine, nanoparticles, nanotechnology, natural materials, self-assembly smart materials, stimuli responsive materials, surface modification, tissue devices, tissue engineering, tissue-derived materials, urological devices.
期刊最新文献
Preventing Oral Dual Biofilm Development with Innovative Bioactive Varnishes. Schiff Base-Crosslinked Tetra-PEG-BSA Hydrogel: Design, Properties, and Multifunctional Functions. The Relationship Between Peri-Implant Marginal Bone Loss and Resonance Frequency Analysis. Bisphenol A Release from Fiber-Reinforced vs. Conventional Stainless-Steel Fixed Retainers: An In Vitro Study. Effect of Sequential vs. Simultaneous Dual Growth Factor Release from Structured Heparin-Poly-Electrolyte Multilayer Coatings on Peri-Implant Bone Formation and Angiogenesis in Pig Mandibles.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1