2岁以下儿童的脑电图和麻醉深度:一项前瞻性观察研究。

IF 1.7 4区 医学 Q2 ANESTHESIOLOGY Pediatric Anesthesia Pub Date : 2025-04-01 Epub Date: 2024-12-26 DOI:10.1111/pan.15058
Soo-Bin Yoon, Jung-Bin Park, Pyoyoon Kang, Young-Eun Jang, Eun-Hee Kim, Ji-Hyun Lee, Hyung-Chul Lee, Jin-Tae Kim, Hee-Soo Kim, Sang-Hwan Ji
{"title":"2岁以下儿童的脑电图和麻醉深度:一项前瞻性观察研究。","authors":"Soo-Bin Yoon, Jung-Bin Park, Pyoyoon Kang, Young-Eun Jang, Eun-Hee Kim, Ji-Hyun Lee, Hyung-Chul Lee, Jin-Tae Kim, Hee-Soo Kim, Sang-Hwan Ji","doi":"10.1111/pan.15058","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Processed electroencephalogram (EEG) indices are widely used to monitor anesthetic depth. However, their reliability in children under 2 years of age remains questionable. During anesthesia maintenance in this age group, processed EEG indices frequently exhibit unexpectedly elevated values that exceed the intended target range.</p><p><strong>Aim: </strong>This study aimed to identify EEG spectral parameters associated with false positive elevations in processed EEG indices and investigate their differences from true positive elevations during emergence.</p><p><strong>Methods: </strong>This prospective observational study included 50 children aged 4-24 months undergoing general anesthesia. Bispectral index (BIS), patient state index (PSi), and raw EEG were continuously recorded throughout anesthesia. False positive was defined as elevated processed EEG indices when end-tidal sevoflurane concentration was maintained at 0.7-1.3 minimum alveolar concentration, with heart rate and mean blood pressure between 80% and 120% of baseline values. We analyzed EEG power spectra and band power values during periods of false positives and compared them with those of true positives during emergence. Bonferroni-corrected p < 0.05 was considered significant.</p><p><strong>Results: </strong>False positives in processed EEG indices were observed in 35 (70%) of the children during anesthesia maintenance, occupying 28% of the maintenance phase. These false positives were associated with decreased power in delta (269-174 dB) and theta (115-97 dB) bands, but widespread increases in alpha and beta bands, resulting in elevated spectral edge frequency (19-22 Hz). Notably, EEG band power during false positives significantly differed from those observed during emergence (delta: 52 dB, theta: 38 dB) (all p < 0.001).</p><p><strong>Conclusions: </strong>Processed EEG indices may exhibit unexpectedly elevated values during anesthesia maintenance in children under 2 years of age. Quantitative assessments derived from raw EEG data may improve the evaluation of anesthetic depth in this population.</p>","PeriodicalId":19745,"journal":{"name":"Pediatric Anesthesia","volume":" ","pages":"294-301"},"PeriodicalIF":1.7000,"publicationDate":"2025-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Electroencephalography and Anesthetic Depth in Children Under 2 Years of Age: A Prospective Observational Study.\",\"authors\":\"Soo-Bin Yoon, Jung-Bin Park, Pyoyoon Kang, Young-Eun Jang, Eun-Hee Kim, Ji-Hyun Lee, Hyung-Chul Lee, Jin-Tae Kim, Hee-Soo Kim, Sang-Hwan Ji\",\"doi\":\"10.1111/pan.15058\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Processed electroencephalogram (EEG) indices are widely used to monitor anesthetic depth. However, their reliability in children under 2 years of age remains questionable. During anesthesia maintenance in this age group, processed EEG indices frequently exhibit unexpectedly elevated values that exceed the intended target range.</p><p><strong>Aim: </strong>This study aimed to identify EEG spectral parameters associated with false positive elevations in processed EEG indices and investigate their differences from true positive elevations during emergence.</p><p><strong>Methods: </strong>This prospective observational study included 50 children aged 4-24 months undergoing general anesthesia. Bispectral index (BIS), patient state index (PSi), and raw EEG were continuously recorded throughout anesthesia. False positive was defined as elevated processed EEG indices when end-tidal sevoflurane concentration was maintained at 0.7-1.3 minimum alveolar concentration, with heart rate and mean blood pressure between 80% and 120% of baseline values. We analyzed EEG power spectra and band power values during periods of false positives and compared them with those of true positives during emergence. Bonferroni-corrected p < 0.05 was considered significant.</p><p><strong>Results: </strong>False positives in processed EEG indices were observed in 35 (70%) of the children during anesthesia maintenance, occupying 28% of the maintenance phase. These false positives were associated with decreased power in delta (269-174 dB) and theta (115-97 dB) bands, but widespread increases in alpha and beta bands, resulting in elevated spectral edge frequency (19-22 Hz). Notably, EEG band power during false positives significantly differed from those observed during emergence (delta: 52 dB, theta: 38 dB) (all p < 0.001).</p><p><strong>Conclusions: </strong>Processed EEG indices may exhibit unexpectedly elevated values during anesthesia maintenance in children under 2 years of age. Quantitative assessments derived from raw EEG data may improve the evaluation of anesthetic depth in this population.</p>\",\"PeriodicalId\":19745,\"journal\":{\"name\":\"Pediatric Anesthesia\",\"volume\":\" \",\"pages\":\"294-301\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2025-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Pediatric Anesthesia\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1111/pan.15058\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/12/26 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"ANESTHESIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pediatric Anesthesia","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/pan.15058","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/12/26 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景:经过处理的脑电图(EEG)指数被广泛用于麻醉深度监测。然而,它们在2岁以下儿童中的可靠性仍然值得怀疑。在该年龄组的麻醉维持期间,处理后的脑电图指数经常出现超出预期目标范围的意外升高值。目的:本研究旨在确定处理后的脑电指标中与假阳性升高相关的脑电频谱参数,并探讨其与紧急情况下真阳性升高的差异。方法:本前瞻性观察研究纳入50例4-24个月的全麻患儿。麻醉期间连续记录双谱指数(BIS)、患者状态指数(PSi)和原始脑电图。当潮末七氟醚浓度维持在0.7-1.3最小肺泡浓度时,心率和平均血压在基线值的80% - 120%之间时,处理脑电图指标升高,即为假阳性。我们分析了假阳性期间的脑电功率谱和频带功率值,并将其与出现时的真阳性进行了比较。结果:麻醉维持期患儿脑电处理指标出现假阳性35例(70%),占维持期的28%。这些假阳性与δ (269-174 dB)和θ (115-97 dB)波段功率下降有关,但α和β波段功率普遍增加,导致频谱边缘频率升高(19-22 Hz)。值得注意的是,假阳性期间的脑电图频带功率与急诊期间的脑电图频带功率显著不同(δ: 52 dB, θ: 38 dB)(均为p)。结论:在2岁以下儿童麻醉维持期间,处理后的脑电图指数可能出现意外升高。从原始脑电图数据得出的定量评估可以改善对该人群麻醉深度的评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Electroencephalography and Anesthetic Depth in Children Under 2 Years of Age: A Prospective Observational Study.

Background: Processed electroencephalogram (EEG) indices are widely used to monitor anesthetic depth. However, their reliability in children under 2 years of age remains questionable. During anesthesia maintenance in this age group, processed EEG indices frequently exhibit unexpectedly elevated values that exceed the intended target range.

Aim: This study aimed to identify EEG spectral parameters associated with false positive elevations in processed EEG indices and investigate their differences from true positive elevations during emergence.

Methods: This prospective observational study included 50 children aged 4-24 months undergoing general anesthesia. Bispectral index (BIS), patient state index (PSi), and raw EEG were continuously recorded throughout anesthesia. False positive was defined as elevated processed EEG indices when end-tidal sevoflurane concentration was maintained at 0.7-1.3 minimum alveolar concentration, with heart rate and mean blood pressure between 80% and 120% of baseline values. We analyzed EEG power spectra and band power values during periods of false positives and compared them with those of true positives during emergence. Bonferroni-corrected p < 0.05 was considered significant.

Results: False positives in processed EEG indices were observed in 35 (70%) of the children during anesthesia maintenance, occupying 28% of the maintenance phase. These false positives were associated with decreased power in delta (269-174 dB) and theta (115-97 dB) bands, but widespread increases in alpha and beta bands, resulting in elevated spectral edge frequency (19-22 Hz). Notably, EEG band power during false positives significantly differed from those observed during emergence (delta: 52 dB, theta: 38 dB) (all p < 0.001).

Conclusions: Processed EEG indices may exhibit unexpectedly elevated values during anesthesia maintenance in children under 2 years of age. Quantitative assessments derived from raw EEG data may improve the evaluation of anesthetic depth in this population.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Pediatric Anesthesia
Pediatric Anesthesia 医学-麻醉学
CiteScore
3.20
自引率
11.80%
发文量
222
审稿时长
3-8 weeks
期刊介绍: Devoted to the dissemination of research of interest and importance to practising anesthetists everywhere, the scientific and clinical content of Pediatric Anesthesia covers a wide selection of medical disciplines in all areas relevant to paediatric anaesthesia, pain management and peri-operative medicine. The International Editorial Board is supported by the Editorial Advisory Board and a team of Senior Advisors, to ensure that the journal is publishing the best work from the front line of research in the field. The journal publishes high-quality, relevant scientific and clinical research papers, reviews, commentaries, pro-con debates, historical vignettes, correspondence, case presentations and book reviews.
期刊最新文献
Methodological Considerations in the Validation of a Digital Pediatric Pain Scale. Intermittent 0.25% Bupivacaine Bolus Administered Through a Serratus Posterior Superior Intercostal Plane Catheter for Postoperative Analgesia Following Posterolateral Thoracotomy. Design for a Reusable High-Fidelity Pediatric Epidural and Caudal Phantom for Haptic Learning. EEG Dynamics in Children Before, During and After General Anesthesia. The Effect of Remimazolam Administration on Emergence Delirium in Children After General Anesthesia: A Systematic Review With Meta-Analysis of Randomized Controlled Trials.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1