使用Milliflex®快速系统结合选择性裂解溶液早期检测细胞产品中的微生物污染物。

Cecile Delbos, Frederic Olivieri, Farah Bouhedda, Estelle Alvergnas, Renaud Chollet
{"title":"使用Milliflex®快速系统结合选择性裂解溶液早期检测细胞产品中的微生物污染物。","authors":"Cecile Delbos, Frederic Olivieri, Farah Bouhedda, Estelle Alvergnas, Renaud Chollet","doi":"10.5731/pdajpst.2024.99907","DOIUrl":null,"url":null,"abstract":"<p><p>The Milliflex<sup>®</sup> Rapid System is a proven automated ATP-based solution used for rapid bioburden and sterility testing. Combining membrane filtration, ATP bioluminescence and imaging, it provides microbial enumeration in significantly less time than traditional methods. Detecting microbial contamination in cell-based products remains a challenge due to filterability issues and interference from mammalian ATP. To address this, a sample processing method has been developed using a selective cell lysis solution and a free ATP removal enzyme effective at both low and high mammalian cells densities. The processing of Chinese Hamster Ovary (CHO) cells ranging from 106 to 107 cells/mL with lysis solution eliminates the mammalian ATP background in 15 minutes. This requires a ratio of 4 mL of lysis solution per mL of sample at 106 cells/mL or 9 mL of lysis solution per mL of sample at 107 cells/mL. CHO cells were inoculated separately with 6 microorganisms including Cutibacterium acnes ATCC 6919 and then processed with the lysis solution before enumeration with the Milliflex<sup>®</sup> Rapid System. Results showed a rapid enumeration of the 6 microorganisms with good recovery according to the control.</p>","PeriodicalId":19986,"journal":{"name":"PDA Journal of Pharmaceutical Science and Technology","volume":"78 6","pages":"763-764"},"PeriodicalIF":0.0000,"publicationDate":"2024-12-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Early Detection of Microbial Contaminants in Cell-Based Products Using the Milliflex<sup>®</sup> Rapid System Combined with a Selective Lysis Solution.\",\"authors\":\"Cecile Delbos, Frederic Olivieri, Farah Bouhedda, Estelle Alvergnas, Renaud Chollet\",\"doi\":\"10.5731/pdajpst.2024.99907\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The Milliflex<sup>®</sup> Rapid System is a proven automated ATP-based solution used for rapid bioburden and sterility testing. Combining membrane filtration, ATP bioluminescence and imaging, it provides microbial enumeration in significantly less time than traditional methods. Detecting microbial contamination in cell-based products remains a challenge due to filterability issues and interference from mammalian ATP. To address this, a sample processing method has been developed using a selective cell lysis solution and a free ATP removal enzyme effective at both low and high mammalian cells densities. The processing of Chinese Hamster Ovary (CHO) cells ranging from 106 to 107 cells/mL with lysis solution eliminates the mammalian ATP background in 15 minutes. This requires a ratio of 4 mL of lysis solution per mL of sample at 106 cells/mL or 9 mL of lysis solution per mL of sample at 107 cells/mL. CHO cells were inoculated separately with 6 microorganisms including Cutibacterium acnes ATCC 6919 and then processed with the lysis solution before enumeration with the Milliflex<sup>®</sup> Rapid System. Results showed a rapid enumeration of the 6 microorganisms with good recovery according to the control.</p>\",\"PeriodicalId\":19986,\"journal\":{\"name\":\"PDA Journal of Pharmaceutical Science and Technology\",\"volume\":\"78 6\",\"pages\":\"763-764\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-12-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"PDA Journal of Pharmaceutical Science and Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5731/pdajpst.2024.99907\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"PDA Journal of Pharmaceutical Science and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5731/pdajpst.2024.99907","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

Milliflex®快速系统是一种经过验证的基于atp的自动化解决方案,用于快速生物负荷和无菌检测。结合膜过滤,ATP生物发光和成像,它提供了微生物计数比传统方法明显更短的时间。由于可过滤性问题和哺乳动物ATP的干扰,检测基于细胞的产品中的微生物污染仍然是一个挑战。为了解决这个问题,已经开发了一种样品处理方法,使用选择性细胞裂解溶液和在低和高哺乳动物细胞密度下有效的游离ATP去除酶。用裂解液处理106 - 107个细胞/mL的中国仓鼠卵巢(CHO)细胞,在15分钟内消除哺乳动物ATP背景。这需要每毫升106个细胞/mL的样品中有4ml的裂解液,或每毫升107个细胞/mL的样品中有9ml的裂解液。CHO细胞分别接种包括痤疮角质杆菌ATCC 6919在内的6种微生物,用裂解液处理后,使用millliflex®快速计数系统进行计数。结果表明,6种微生物的计数速度快,回收率好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Early Detection of Microbial Contaminants in Cell-Based Products Using the Milliflex® Rapid System Combined with a Selective Lysis Solution.

The Milliflex® Rapid System is a proven automated ATP-based solution used for rapid bioburden and sterility testing. Combining membrane filtration, ATP bioluminescence and imaging, it provides microbial enumeration in significantly less time than traditional methods. Detecting microbial contamination in cell-based products remains a challenge due to filterability issues and interference from mammalian ATP. To address this, a sample processing method has been developed using a selective cell lysis solution and a free ATP removal enzyme effective at both low and high mammalian cells densities. The processing of Chinese Hamster Ovary (CHO) cells ranging from 106 to 107 cells/mL with lysis solution eliminates the mammalian ATP background in 15 minutes. This requires a ratio of 4 mL of lysis solution per mL of sample at 106 cells/mL or 9 mL of lysis solution per mL of sample at 107 cells/mL. CHO cells were inoculated separately with 6 microorganisms including Cutibacterium acnes ATCC 6919 and then processed with the lysis solution before enumeration with the Milliflex® Rapid System. Results showed a rapid enumeration of the 6 microorganisms with good recovery according to the control.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.90
自引率
0.00%
发文量
34
期刊最新文献
A Risk Assessment and Risk Based Approach Review of Pre-use/Post Sterilization Integrity Testing (PUPSIT). Case Study: Visual Inspection of Topical Ophthalmic Formulations Packaged in Opaque and Semi-Transparent Containers: Working towards alignment with USP<790> Visible Inspection of Injections. Addressing Medical Device Extractables and Leachables via Non-Target Analysis (NTA); The Analytical Evaluation Threshold (AET) and Quantitation. Definition of particle visibility threshold in parenteral drug products - towards standardization of visual inspection operator qualification. Recommendations for Artificial Intelligence Application in Continued Process Verification.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1