{"title":"基于深度学习的卒中后肌电手势识别:从特征构建到网络设计","authors":"Tianzhe Bao;Zhiyuan Lu;Ping Zhou","doi":"10.1109/TNSRE.2024.3521583","DOIUrl":null,"url":null,"abstract":"Recently, robot-assisted rehabilitation has emerged as a promising solution to increase the training intensity of stroke patients while reducing workload on therapists, whilst surface electromyography (sEMG) is expected to serve as a viable control source. In this paper, we delve into the potential of deep learning (DL) for post-stroke hand gesture recognition by collecting the sEMG signals of eight chronic stroke subjects, focusing on three primary aspects: feature domains of sEMG (time, frequency, and wavelet), data structures (one or two-dimensional images), and neural network architectures (CNN, CNN-LSTM, and CNN-LSTM-Attention). A total of 18 DL models were comprehensively evaluated in both intra-subject testing and inter-subject transfer learning tasks, with two post-processing algorithms (Model Voting and Bayesian Fusion) analysed subsequently. Experiment results infer that for intra-subject testing, the average accuracy of CNN-LSTM using two-dimensional frequency features is the highest, reaching 72.95%. For inter-subject transfer learning, the average accuracy of CNN-LSTM-Attention using one-dimensional frequency features is the highest, reaching 68.38%. Through these two experiments, it was found that frequency features had significant advantages over other features in gesture recognition after stroke. Moreover, the post-processing algorithm can further improve the recognition accuracy, and the recognition effect can be increased by 2.03% through the model voting algorithm.","PeriodicalId":13419,"journal":{"name":"IEEE Transactions on Neural Systems and Rehabilitation Engineering","volume":"33 ","pages":"191-200"},"PeriodicalIF":4.8000,"publicationDate":"2024-12-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10812756","citationCount":"0","resultStr":"{\"title\":\"Deep Learning-Based Post-Stroke Myoelectric Gesture Recognition: From Feature Construction to Network Design\",\"authors\":\"Tianzhe Bao;Zhiyuan Lu;Ping Zhou\",\"doi\":\"10.1109/TNSRE.2024.3521583\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Recently, robot-assisted rehabilitation has emerged as a promising solution to increase the training intensity of stroke patients while reducing workload on therapists, whilst surface electromyography (sEMG) is expected to serve as a viable control source. In this paper, we delve into the potential of deep learning (DL) for post-stroke hand gesture recognition by collecting the sEMG signals of eight chronic stroke subjects, focusing on three primary aspects: feature domains of sEMG (time, frequency, and wavelet), data structures (one or two-dimensional images), and neural network architectures (CNN, CNN-LSTM, and CNN-LSTM-Attention). A total of 18 DL models were comprehensively evaluated in both intra-subject testing and inter-subject transfer learning tasks, with two post-processing algorithms (Model Voting and Bayesian Fusion) analysed subsequently. Experiment results infer that for intra-subject testing, the average accuracy of CNN-LSTM using two-dimensional frequency features is the highest, reaching 72.95%. For inter-subject transfer learning, the average accuracy of CNN-LSTM-Attention using one-dimensional frequency features is the highest, reaching 68.38%. Through these two experiments, it was found that frequency features had significant advantages over other features in gesture recognition after stroke. Moreover, the post-processing algorithm can further improve the recognition accuracy, and the recognition effect can be increased by 2.03% through the model voting algorithm.\",\"PeriodicalId\":13419,\"journal\":{\"name\":\"IEEE Transactions on Neural Systems and Rehabilitation Engineering\",\"volume\":\"33 \",\"pages\":\"191-200\"},\"PeriodicalIF\":4.8000,\"publicationDate\":\"2024-12-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10812756\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Transactions on Neural Systems and Rehabilitation Engineering\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/10812756/\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Neural Systems and Rehabilitation Engineering","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/10812756/","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
Deep Learning-Based Post-Stroke Myoelectric Gesture Recognition: From Feature Construction to Network Design
Recently, robot-assisted rehabilitation has emerged as a promising solution to increase the training intensity of stroke patients while reducing workload on therapists, whilst surface electromyography (sEMG) is expected to serve as a viable control source. In this paper, we delve into the potential of deep learning (DL) for post-stroke hand gesture recognition by collecting the sEMG signals of eight chronic stroke subjects, focusing on three primary aspects: feature domains of sEMG (time, frequency, and wavelet), data structures (one or two-dimensional images), and neural network architectures (CNN, CNN-LSTM, and CNN-LSTM-Attention). A total of 18 DL models were comprehensively evaluated in both intra-subject testing and inter-subject transfer learning tasks, with two post-processing algorithms (Model Voting and Bayesian Fusion) analysed subsequently. Experiment results infer that for intra-subject testing, the average accuracy of CNN-LSTM using two-dimensional frequency features is the highest, reaching 72.95%. For inter-subject transfer learning, the average accuracy of CNN-LSTM-Attention using one-dimensional frequency features is the highest, reaching 68.38%. Through these two experiments, it was found that frequency features had significant advantages over other features in gesture recognition after stroke. Moreover, the post-processing algorithm can further improve the recognition accuracy, and the recognition effect can be increased by 2.03% through the model voting algorithm.
期刊介绍:
Rehabilitative and neural aspects of biomedical engineering, including functional electrical stimulation, acoustic dynamics, human performance measurement and analysis, nerve stimulation, electromyography, motor control and stimulation; and hardware and software applications for rehabilitation engineering and assistive devices.