CAD-CAM系统制造的两种不同设计的牙冠边缘拟合精度的比较研究。

IF 1 Q3 DENTISTRY, ORAL SURGERY & MEDICINE The Journal of Indian Prosthodontic Society Pub Date : 2025-01-01 Epub Date: 2025-01-03 DOI:10.4103/jips.jips_207_24
Khushbu Rakesh Gupta, Deepesh Kumar Gupta, Anumeha Jha, Shivam B Shukla, Aayush Mukund Dubey
{"title":"CAD-CAM系统制造的两种不同设计的牙冠边缘拟合精度的比较研究。","authors":"Khushbu Rakesh Gupta, Deepesh Kumar Gupta, Anumeha Jha, Shivam B Shukla, Aayush Mukund Dubey","doi":"10.4103/jips.jips_207_24","DOIUrl":null,"url":null,"abstract":"<p><strong>Aims: </strong>To compare the accuracy of marginal fit of CAD-CAM endocrown with two different preparation forms, i.e., endocrown with ferrule and endocrown without ferrule.</p><p><strong>Settings and design: </strong>Various studies have opined on the impact of preparation form on the marginal fit of endocrown, but studies on the effect on the marginal fit of digitally milled endocrown with and without ferrule are sparse.</p><p><strong>Materials and methods: </strong>Total of 30 typodont were sectioned 3 mm above the cemento-enamel junction, and central cavity was prepared to depict a severely destructed tooth. The typodonts were divided into two groups: Group 1 contained specimens for endocrown without ferrule (WoF); Group 2 contained specimens for endocrown with ferrule (WF). The typodonts were prepared based on standard preparation. The specimens were then scanned using intraoral scanner, and the stereolithography (STL) was generated. Endocrowns were designed in the Exocad software using a digital library. The STL file format is translated into millable data file format (CNC- Computer numerical control) in the inLAB MC X5 Milling machine. The marginal fit of endocrowns was then assessed in the stereomicroscope.</p><p><strong>Statistical analysis: </strong>The data was analysed with a digital image analyser. The result was generated using a two-way ANOVA test. The significance level was set at P ≤ 0.05.</p><p><strong>Results: </strong>In the present study, the marginal fit of WoF showed a superior marginal fit than WF. A statistically significant difference was seen in the marginal fit of two endocrowns, with a higher marginal discrepancy observed in the endocrown with the ferrule. The P value for the difference in the means of the marginal gap without and with ferrule (-13.42) is zero. Maximum marginal gap of 96 micron is observed for with ferrule (WF) design at location B. Minimum marginal gap of 29 micron is observed for without ferrule (WoF) at location D.</p><p><strong>Conclusions: </strong>Endocrown without a ferrule can provide a better marginal fit and can contribute to the long-term survival of restoration.</p>","PeriodicalId":22669,"journal":{"name":"The Journal of Indian Prosthodontic Society","volume":"25 1","pages":"74-79"},"PeriodicalIF":1.0000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparative evaluation of marginal fit accuracy of two different designs of endocrown manufactured through CAD-CAM system: An in vitro study.\",\"authors\":\"Khushbu Rakesh Gupta, Deepesh Kumar Gupta, Anumeha Jha, Shivam B Shukla, Aayush Mukund Dubey\",\"doi\":\"10.4103/jips.jips_207_24\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Aims: </strong>To compare the accuracy of marginal fit of CAD-CAM endocrown with two different preparation forms, i.e., endocrown with ferrule and endocrown without ferrule.</p><p><strong>Settings and design: </strong>Various studies have opined on the impact of preparation form on the marginal fit of endocrown, but studies on the effect on the marginal fit of digitally milled endocrown with and without ferrule are sparse.</p><p><strong>Materials and methods: </strong>Total of 30 typodont were sectioned 3 mm above the cemento-enamel junction, and central cavity was prepared to depict a severely destructed tooth. The typodonts were divided into two groups: Group 1 contained specimens for endocrown without ferrule (WoF); Group 2 contained specimens for endocrown with ferrule (WF). The typodonts were prepared based on standard preparation. The specimens were then scanned using intraoral scanner, and the stereolithography (STL) was generated. Endocrowns were designed in the Exocad software using a digital library. The STL file format is translated into millable data file format (CNC- Computer numerical control) in the inLAB MC X5 Milling machine. The marginal fit of endocrowns was then assessed in the stereomicroscope.</p><p><strong>Statistical analysis: </strong>The data was analysed with a digital image analyser. The result was generated using a two-way ANOVA test. The significance level was set at P ≤ 0.05.</p><p><strong>Results: </strong>In the present study, the marginal fit of WoF showed a superior marginal fit than WF. A statistically significant difference was seen in the marginal fit of two endocrowns, with a higher marginal discrepancy observed in the endocrown with the ferrule. The P value for the difference in the means of the marginal gap without and with ferrule (-13.42) is zero. Maximum marginal gap of 96 micron is observed for with ferrule (WF) design at location B. Minimum marginal gap of 29 micron is observed for without ferrule (WoF) at location D.</p><p><strong>Conclusions: </strong>Endocrown without a ferrule can provide a better marginal fit and can contribute to the long-term survival of restoration.</p>\",\"PeriodicalId\":22669,\"journal\":{\"name\":\"The Journal of Indian Prosthodontic Society\",\"volume\":\"25 1\",\"pages\":\"74-79\"},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2025-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Journal of Indian Prosthodontic Society\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/jips.jips_207_24\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/1/3 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of Indian Prosthodontic Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jips.jips_207_24","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/3 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:比较CAD-CAM内冠带卡箍和不带卡箍两种不同制备形式的边缘配合精度。设置与设计:关于预备形式对内冠边缘配合的影响已有多种研究,但关于带卡圈和不带卡圈的数字铣削内冠对其边缘配合影响的研究较少。材料和方法:在牙髓-牙釉质交界处上方3mm处切出30个印型,并准备中央空腔来描绘严重受损的牙齿。分两组:第1组为内冠无卡套(endocrown without ferrule)标本;第2组为带箍内冠标本(endocrown with ferrule, WF)。排字是在标准准备的基础上准备的。然后使用口内扫描仪对标本进行扫描,并生成立体光刻(STL)。在Exocad软件中使用数字图书馆设计牙冠。在inLAB MC X5铣床中将STL文件格式转换为可铣削数据文件格式(CNC-计算机数控)。然后在体视显微镜下评估内冠的边缘贴合。统计分析:用数字图像分析仪对数据进行分析。结果采用双向方差分析检验产生。显著性水平为P≤0.05。结果:在本研究中,WoF的边缘拟合优于WF。两种内冠的边缘配合有统计学上的显著差异,带卡箍的内冠的边缘配合差异更大。不带箍和带箍的边际间隙均值之差(-13.42)的P值为零。有卡箍(WF)设计的b位置的最大边缘间隙为96微米,无卡箍(WoF)设计的d位置的最小边缘间隙为29微米。结论:无卡箍的内冠可以提供更好的边缘配合,有助于修复的长期生存。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Comparative evaluation of marginal fit accuracy of two different designs of endocrown manufactured through CAD-CAM system: An in vitro study.

Aims: To compare the accuracy of marginal fit of CAD-CAM endocrown with two different preparation forms, i.e., endocrown with ferrule and endocrown without ferrule.

Settings and design: Various studies have opined on the impact of preparation form on the marginal fit of endocrown, but studies on the effect on the marginal fit of digitally milled endocrown with and without ferrule are sparse.

Materials and methods: Total of 30 typodont were sectioned 3 mm above the cemento-enamel junction, and central cavity was prepared to depict a severely destructed tooth. The typodonts were divided into two groups: Group 1 contained specimens for endocrown without ferrule (WoF); Group 2 contained specimens for endocrown with ferrule (WF). The typodonts were prepared based on standard preparation. The specimens were then scanned using intraoral scanner, and the stereolithography (STL) was generated. Endocrowns were designed in the Exocad software using a digital library. The STL file format is translated into millable data file format (CNC- Computer numerical control) in the inLAB MC X5 Milling machine. The marginal fit of endocrowns was then assessed in the stereomicroscope.

Statistical analysis: The data was analysed with a digital image analyser. The result was generated using a two-way ANOVA test. The significance level was set at P ≤ 0.05.

Results: In the present study, the marginal fit of WoF showed a superior marginal fit than WF. A statistically significant difference was seen in the marginal fit of two endocrowns, with a higher marginal discrepancy observed in the endocrown with the ferrule. The P value for the difference in the means of the marginal gap without and with ferrule (-13.42) is zero. Maximum marginal gap of 96 micron is observed for with ferrule (WF) design at location B. Minimum marginal gap of 29 micron is observed for without ferrule (WoF) at location D.

Conclusions: Endocrown without a ferrule can provide a better marginal fit and can contribute to the long-term survival of restoration.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
The Journal of Indian Prosthodontic Society
The Journal of Indian Prosthodontic Society DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
2.20
自引率
8.30%
发文量
26
审稿时长
20 weeks
期刊最新文献
Comparison of the antibacterial efficacy of 810 nm diode laser and photodynamic therapy in reducing microbial flora in patients with peri-implant mucositis - An in vivo study. Evaluation of marginal accuracy of polyetheretherketone and zirconia copings fabricated using computer-aided design/computer-aided manufacturing technique: An in vitro study. Incorporation of opacifier to Type III alpha gypsum and its effect on scannability and linear setting expansion - An in vitro study. Over-provisionals - Simplified chairside preoperative evaluation of esthetic and functional changes during full mouth rehabilitation. Reporting guidelines: Elevating standards in scientific communication.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1