Artit Songwatcharaporn, Sharanbir K Sidhu, K Elizabeth Tanner
{"title":"铣削牙本质模拟材料粘合牙合贴面的计算机辅助设计与制造的准静态力学试验。","authors":"Artit Songwatcharaporn, Sharanbir K Sidhu, K Elizabeth Tanner","doi":"10.3791/67511","DOIUrl":null,"url":null,"abstract":"<p><p>Under current minimally invasive treatment regimes, minor tooth preparation and thinner biomimetic ceramic restoration are used to preserve the restored tooth's vitality, aesthetics, and function. New computer-aided design and computer-aided manufacturing (CAD/CAM) ceramic-like material are now available. To guarantee longevity, a dental clinician must know these newly launched product's mechanical strength compared to the relatively brittle glass-matrix ceramic. Furthermore, a tooth substitute has been promoted for laboratory investigation, especially after the pandemic, and more evidentiary support is required for its application. This study developed a laboratory protocol for a monotonic load-to-fracture test to determine the fracture strength of 1 mm-thick CAD/CAM occlusal veneers. Master dies were milled from high-pressure fiberglass laminate, which has similar elastic modulus and bond strength as hydrated dentin. They were mounted into polyvinyl chloride (PVC) end caps with cold-curing epoxy resin. Occlusal veneers, also called tabletop restorations, were milled from lithium disilicate (LD) and resin nanoceramic blocks (RNC) and cemented to prepared master dies using dual-cured adhesive resin cement. They were allowed to cure fully by storing in distilled water for 48 h at 37 °C. All samples were then placed in a universal testing machine and loaded via a non-fixed 5.5 mm stainless-steel ball that allows lateral movement as would occur against the antagonist teeth. Compression was applied at a 1 mm/min rate, and the load-displacement graph was generated. The average maximum load-bearing capacity of restorations in the RNC group (3,212.80 ± 558.67 N) was significantly higher than in the LD group (2727.10 ± 472.41 N) (p < 0.05). No debonding was found during the test. Both CAD/CAM materials may have a similar flaw distribution. Hertzian cone crack was found at the loading site, whereas radial cracks propagating from the cementation surface were found close to the margin in both groups.</p>","PeriodicalId":48787,"journal":{"name":"Jove-Journal of Visualized Experiments","volume":" 214","pages":""},"PeriodicalIF":1.2000,"publicationDate":"2024-12-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material.\",\"authors\":\"Artit Songwatcharaporn, Sharanbir K Sidhu, K Elizabeth Tanner\",\"doi\":\"10.3791/67511\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Under current minimally invasive treatment regimes, minor tooth preparation and thinner biomimetic ceramic restoration are used to preserve the restored tooth's vitality, aesthetics, and function. New computer-aided design and computer-aided manufacturing (CAD/CAM) ceramic-like material are now available. To guarantee longevity, a dental clinician must know these newly launched product's mechanical strength compared to the relatively brittle glass-matrix ceramic. Furthermore, a tooth substitute has been promoted for laboratory investigation, especially after the pandemic, and more evidentiary support is required for its application. This study developed a laboratory protocol for a monotonic load-to-fracture test to determine the fracture strength of 1 mm-thick CAD/CAM occlusal veneers. Master dies were milled from high-pressure fiberglass laminate, which has similar elastic modulus and bond strength as hydrated dentin. They were mounted into polyvinyl chloride (PVC) end caps with cold-curing epoxy resin. Occlusal veneers, also called tabletop restorations, were milled from lithium disilicate (LD) and resin nanoceramic blocks (RNC) and cemented to prepared master dies using dual-cured adhesive resin cement. They were allowed to cure fully by storing in distilled water for 48 h at 37 °C. All samples were then placed in a universal testing machine and loaded via a non-fixed 5.5 mm stainless-steel ball that allows lateral movement as would occur against the antagonist teeth. Compression was applied at a 1 mm/min rate, and the load-displacement graph was generated. The average maximum load-bearing capacity of restorations in the RNC group (3,212.80 ± 558.67 N) was significantly higher than in the LD group (2727.10 ± 472.41 N) (p < 0.05). No debonding was found during the test. Both CAD/CAM materials may have a similar flaw distribution. Hertzian cone crack was found at the loading site, whereas radial cracks propagating from the cementation surface were found close to the margin in both groups.</p>\",\"PeriodicalId\":48787,\"journal\":{\"name\":\"Jove-Journal of Visualized Experiments\",\"volume\":\" 214\",\"pages\":\"\"},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2024-12-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Jove-Journal of Visualized Experiments\",\"FirstCategoryId\":\"103\",\"ListUrlMain\":\"https://doi.org/10.3791/67511\",\"RegionNum\":4,\"RegionCategory\":\"综合性期刊\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"MULTIDISCIPLINARY SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jove-Journal of Visualized Experiments","FirstCategoryId":"103","ListUrlMain":"https://doi.org/10.3791/67511","RegionNum":4,"RegionCategory":"综合性期刊","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MULTIDISCIPLINARY SCIENCES","Score":null,"Total":0}
Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material.
Under current minimally invasive treatment regimes, minor tooth preparation and thinner biomimetic ceramic restoration are used to preserve the restored tooth's vitality, aesthetics, and function. New computer-aided design and computer-aided manufacturing (CAD/CAM) ceramic-like material are now available. To guarantee longevity, a dental clinician must know these newly launched product's mechanical strength compared to the relatively brittle glass-matrix ceramic. Furthermore, a tooth substitute has been promoted for laboratory investigation, especially after the pandemic, and more evidentiary support is required for its application. This study developed a laboratory protocol for a monotonic load-to-fracture test to determine the fracture strength of 1 mm-thick CAD/CAM occlusal veneers. Master dies were milled from high-pressure fiberglass laminate, which has similar elastic modulus and bond strength as hydrated dentin. They were mounted into polyvinyl chloride (PVC) end caps with cold-curing epoxy resin. Occlusal veneers, also called tabletop restorations, were milled from lithium disilicate (LD) and resin nanoceramic blocks (RNC) and cemented to prepared master dies using dual-cured adhesive resin cement. They were allowed to cure fully by storing in distilled water for 48 h at 37 °C. All samples were then placed in a universal testing machine and loaded via a non-fixed 5.5 mm stainless-steel ball that allows lateral movement as would occur against the antagonist teeth. Compression was applied at a 1 mm/min rate, and the load-displacement graph was generated. The average maximum load-bearing capacity of restorations in the RNC group (3,212.80 ± 558.67 N) was significantly higher than in the LD group (2727.10 ± 472.41 N) (p < 0.05). No debonding was found during the test. Both CAD/CAM materials may have a similar flaw distribution. Hertzian cone crack was found at the loading site, whereas radial cracks propagating from the cementation surface were found close to the margin in both groups.
期刊介绍:
JoVE, the Journal of Visualized Experiments, is the world''s first peer reviewed scientific video journal. Established in 2006, JoVE is devoted to publishing scientific research in a visual format to help researchers overcome two of the biggest challenges facing the scientific research community today; poor reproducibility and the time and labor intensive nature of learning new experimental techniques.