用液相色谱-串联质谱(LC-MS/MS)分析短鳍领航鲸脂肪中的多类类固醇。

IF 1.8 3区 化学 Q4 BIOCHEMICAL RESEARCH METHODS Rapid Communications in Mass Spectrometry Pub Date : 2025-01-12 DOI:10.1002/rcm.9965
Jillian H. Wisse, Douglas P. Nowacek, Ashley S. P. Boggs
{"title":"用液相色谱-串联质谱(LC-MS/MS)分析短鳍领航鲸脂肪中的多类类固醇。","authors":"Jillian H. Wisse,&nbsp;Douglas P. Nowacek,&nbsp;Ashley S. P. Boggs","doi":"10.1002/rcm.9965","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Rationale</h3>\n \n <p>Wildlife scientists are quantifying steroid hormones in a growing number of tissues and employing novel methods that must undergo validation before application. This study tested the accuracy and precision of liquid chromatography–tandem mass spectrometry (LC-MS/MS) methods for use on blubber samples from short-finned pilot whales (<i>Globicephala macrorhynchus</i>). We expanded upon a method for corticosteroid quantification by adding analytes and optimizing internal standard (IS) application.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>We optimized a method for the quantification of seven steroid hormones using LC-MS/MS with a C18 column. We assessed the accuracy and precision of this updated C18 method and an existing biphenyl method for use with pilot whale blubber by conducting a spike recovery experiment and calculating percent recovery and relative standard deviation (RSD) for each analyte. To explore the potential for running this method with fewer matched ISs, we compared the performance of multiple ISs for each analyte.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>All 11 adrenal and gonadal analytes showed good accuracy and precision in the spike recovery experiment, with recoveries between 82% and 110% and recovery RSDs below 10%. The C18 method detected all analytes at endogenous concentrations, except aldosterone. Although endogenous DHEA was detected, variability was high. IS comparisons showed 10 of 11 analytes could be calculated with comparable accuracy and precision using an IS substitute, but some substitutions significantly altered the analyte concentrations calculated.</p>\n </section>\n \n <section>\n \n <h3> Discussion</h3>\n \n <p>The C18 method was not sensitive enough for endogenous aldosterone detection. DHEA, which has not been previously quantified in blubber, was detected in all samples, but with high variability at lower concentrations. The methods in this study provide reliable detection and quantification of the other nine hormones tested and can be used for assessments of adrenal and gonadal steroid hormones from whales. Laboratories can reduce costs through IS substitution but should consider how these substitutions affect results.</p>\n </section>\n </div>","PeriodicalId":225,"journal":{"name":"Rapid Communications in Mass Spectrometry","volume":"39 6","pages":""},"PeriodicalIF":1.8000,"publicationDate":"2025-01-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Multiclass Steroid Profiling in Short-Finned Pilot Whale Blubber Using Liquid Chromatography–Tandem Mass Spectrometry (LC-MS/MS)\",\"authors\":\"Jillian H. Wisse,&nbsp;Douglas P. Nowacek,&nbsp;Ashley S. P. Boggs\",\"doi\":\"10.1002/rcm.9965\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n \\n <section>\\n \\n <h3> Rationale</h3>\\n \\n <p>Wildlife scientists are quantifying steroid hormones in a growing number of tissues and employing novel methods that must undergo validation before application. This study tested the accuracy and precision of liquid chromatography–tandem mass spectrometry (LC-MS/MS) methods for use on blubber samples from short-finned pilot whales (<i>Globicephala macrorhynchus</i>). We expanded upon a method for corticosteroid quantification by adding analytes and optimizing internal standard (IS) application.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Methods</h3>\\n \\n <p>We optimized a method for the quantification of seven steroid hormones using LC-MS/MS with a C18 column. We assessed the accuracy and precision of this updated C18 method and an existing biphenyl method for use with pilot whale blubber by conducting a spike recovery experiment and calculating percent recovery and relative standard deviation (RSD) for each analyte. To explore the potential for running this method with fewer matched ISs, we compared the performance of multiple ISs for each analyte.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Results</h3>\\n \\n <p>All 11 adrenal and gonadal analytes showed good accuracy and precision in the spike recovery experiment, with recoveries between 82% and 110% and recovery RSDs below 10%. The C18 method detected all analytes at endogenous concentrations, except aldosterone. Although endogenous DHEA was detected, variability was high. IS comparisons showed 10 of 11 analytes could be calculated with comparable accuracy and precision using an IS substitute, but some substitutions significantly altered the analyte concentrations calculated.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Discussion</h3>\\n \\n <p>The C18 method was not sensitive enough for endogenous aldosterone detection. DHEA, which has not been previously quantified in blubber, was detected in all samples, but with high variability at lower concentrations. The methods in this study provide reliable detection and quantification of the other nine hormones tested and can be used for assessments of adrenal and gonadal steroid hormones from whales. Laboratories can reduce costs through IS substitution but should consider how these substitutions affect results.</p>\\n </section>\\n </div>\",\"PeriodicalId\":225,\"journal\":{\"name\":\"Rapid Communications in Mass Spectrometry\",\"volume\":\"39 6\",\"pages\":\"\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2025-01-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Rapid Communications in Mass Spectrometry\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/rcm.9965\",\"RegionNum\":3,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Rapid Communications in Mass Spectrometry","FirstCategoryId":"92","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/rcm.9965","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

摘要

理由:野生动物科学家正在对越来越多的组织中的类固醇激素进行量化,并采用在应用前必须经过验证的新方法。本研究检验了液相色谱-串联质谱(LC-MS/MS)方法用于短鳍领航鲸(Globicephala macrorhynchus)鲸脂样品的准确性和精密度。我们通过添加分析物和优化内标(IS)应用扩展了皮质类固醇定量方法。方法:优化了C18柱LC-MS/MS定量7种类固醇激素的方法。我们通过进行尖峰回收率实验并计算每种分析物的回收率百分比和相对标准偏差(RSD)来评估这种更新的C18方法和现有的用于领航鲸脂的联苯方法的准确性和精密度。为了探索使用较少匹配的ISs运行该方法的潜力,我们比较了每种分析物的多个ISs的性能。结果:11种肾上腺和性腺分析物在尖峰回收率实验中均具有良好的准确度和精密度,回收率在82% ~ 110%之间,rsd均在10%以下。除醛固酮外,C18法检测所有内源性浓度的分析物。虽然检测到内源性脱氢表雄酮,但变异性很大。IS比较显示,使用IS替代品可以计算出11种分析物中的10种具有相当的准确性和精密度,但一些替代显着改变了计算出的分析物浓度。讨论:C18法检测内源性醛固酮不够灵敏。脱氢表雄酮(DHEA)以前没有在鲸脂中被量化,但在所有样本中都检测到,但在较低浓度下具有很高的变异性。本研究的方法为其他九种激素的检测和定量提供了可靠的方法,并可用于评估鲸鱼的肾上腺激素和性腺类固醇激素。实验室可以通过IS替代降低成本,但应考虑这些替代如何影响结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Multiclass Steroid Profiling in Short-Finned Pilot Whale Blubber Using Liquid Chromatography–Tandem Mass Spectrometry (LC-MS/MS)

Rationale

Wildlife scientists are quantifying steroid hormones in a growing number of tissues and employing novel methods that must undergo validation before application. This study tested the accuracy and precision of liquid chromatography–tandem mass spectrometry (LC-MS/MS) methods for use on blubber samples from short-finned pilot whales (Globicephala macrorhynchus). We expanded upon a method for corticosteroid quantification by adding analytes and optimizing internal standard (IS) application.

Methods

We optimized a method for the quantification of seven steroid hormones using LC-MS/MS with a C18 column. We assessed the accuracy and precision of this updated C18 method and an existing biphenyl method for use with pilot whale blubber by conducting a spike recovery experiment and calculating percent recovery and relative standard deviation (RSD) for each analyte. To explore the potential for running this method with fewer matched ISs, we compared the performance of multiple ISs for each analyte.

Results

All 11 adrenal and gonadal analytes showed good accuracy and precision in the spike recovery experiment, with recoveries between 82% and 110% and recovery RSDs below 10%. The C18 method detected all analytes at endogenous concentrations, except aldosterone. Although endogenous DHEA was detected, variability was high. IS comparisons showed 10 of 11 analytes could be calculated with comparable accuracy and precision using an IS substitute, but some substitutions significantly altered the analyte concentrations calculated.

Discussion

The C18 method was not sensitive enough for endogenous aldosterone detection. DHEA, which has not been previously quantified in blubber, was detected in all samples, but with high variability at lower concentrations. The methods in this study provide reliable detection and quantification of the other nine hormones tested and can be used for assessments of adrenal and gonadal steroid hormones from whales. Laboratories can reduce costs through IS substitution but should consider how these substitutions affect results.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.10
自引率
5.00%
发文量
219
审稿时长
2.6 months
期刊介绍: Rapid Communications in Mass Spectrometry is a journal whose aim is the rapid publication of original research results and ideas on all aspects of the science of gas-phase ions; it covers all the associated scientific disciplines. There is no formal limit on paper length ("rapid" is not synonymous with "brief"), but papers should be of a length that is commensurate with the importance and complexity of the results being reported. Contributions may be theoretical or practical in nature; they may deal with methods, techniques and applications, or with the interpretation of results; they may cover any area in science that depends directly on measurements made upon gaseous ions or that is associated with such measurements.
期刊最新文献
Professor Jean-Francois Muller (1940-2024) Mass Spectrometry and Laser Desorption/Ionisation. Testing Assumptions for Stable Isotope Analysis of Marine Mammal Dentin Growth Layer Groups Unveiling Impurity Profiling of Synthetic Pathways of Organophosphorus Chlorpyrifos Through LC-HRMS Metabolomics-Based Approaches. Systematic Profile of Oxylipins in Myocardial Infarction by Liquid Chromatography–Tandem Mass Spectrometry Fentanyl and Fentanyl Analog Screening Using ASAP-MS With LiveID Confirmation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1