基于手性碳点的双比例荧光传感器用于精氨酸的灵敏和特异检测

IF 6.7 1区 化学 Q1 CHEMISTRY, ANALYTICAL Analytical Chemistry Pub Date : 2025-01-15 DOI:10.1021/acs.analchem.4c06405
Min Liu, Huanhuan Zhang, Chenzhao Wang, Kaihua Su, Kaixin Hu, Enqi Liu, Boyao Sun, Xuechun Li, Guoying Sun, Lehui Lu
{"title":"基于手性碳点的双比例荧光传感器用于精氨酸的灵敏和特异检测","authors":"Min Liu, Huanhuan Zhang, Chenzhao Wang, Kaihua Su, Kaixin Hu, Enqi Liu, Boyao Sun, Xuechun Li, Guoying Sun, Lehui Lu","doi":"10.1021/acs.analchem.4c06405","DOIUrl":null,"url":null,"abstract":"Arginine (Arg) is involved in tissue metabolism and regulates the immune function; thereby, achieving the detection of Arg is crucial for early diagnosis and treatment of diseases. Herein, dual ratiometric fluorescence sensors were prepared with the blue emission of levorotatory/dextrorotatory carbon dots (CDs) and the red emission of porphyrin (L/D-CDs-PP) for the sensitive and portable detection of Arg. Interestingly, L-CDs-PP and D-CDs-PP displayed not only the dual emission peaks at 493 and 650 nm but also different response modes to Arg; thus, they could serve as dual ratiometric fluorescence sensors to achieve the accurate and reliable detection of Arg, with the detection limit of 23.87 μM for L-CDs-PP and 2.39 μM for D-CDs-PP. Importantly, the solid-state sensors successfully achieved dual-mode visual and portable detection of Arg with the support of a smartphone platform. In addition, L-CDs-PP and D-CDs-PP exhibited excellent biocompatibility and cell imaging capabilities, and they could achieve the detection of Arg in cells and biological samples of urine and rat plasma. Therefore, the dual ratiometric fluorescence sensors exhibited broad application prospects in the fields of analytical sensing, biological imaging, and medical diagnosis.","PeriodicalId":27,"journal":{"name":"Analytical Chemistry","volume":"23 1","pages":""},"PeriodicalIF":6.7000,"publicationDate":"2025-01-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Dual Ratiometric Fluorescence Sensors Based on Chiral Carbon Dots for the Sensitive and Specific Detection of Arginine\",\"authors\":\"Min Liu, Huanhuan Zhang, Chenzhao Wang, Kaihua Su, Kaixin Hu, Enqi Liu, Boyao Sun, Xuechun Li, Guoying Sun, Lehui Lu\",\"doi\":\"10.1021/acs.analchem.4c06405\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Arginine (Arg) is involved in tissue metabolism and regulates the immune function; thereby, achieving the detection of Arg is crucial for early diagnosis and treatment of diseases. Herein, dual ratiometric fluorescence sensors were prepared with the blue emission of levorotatory/dextrorotatory carbon dots (CDs) and the red emission of porphyrin (L/D-CDs-PP) for the sensitive and portable detection of Arg. Interestingly, L-CDs-PP and D-CDs-PP displayed not only the dual emission peaks at 493 and 650 nm but also different response modes to Arg; thus, they could serve as dual ratiometric fluorescence sensors to achieve the accurate and reliable detection of Arg, with the detection limit of 23.87 μM for L-CDs-PP and 2.39 μM for D-CDs-PP. Importantly, the solid-state sensors successfully achieved dual-mode visual and portable detection of Arg with the support of a smartphone platform. In addition, L-CDs-PP and D-CDs-PP exhibited excellent biocompatibility and cell imaging capabilities, and they could achieve the detection of Arg in cells and biological samples of urine and rat plasma. Therefore, the dual ratiometric fluorescence sensors exhibited broad application prospects in the fields of analytical sensing, biological imaging, and medical diagnosis.\",\"PeriodicalId\":27,\"journal\":{\"name\":\"Analytical Chemistry\",\"volume\":\"23 1\",\"pages\":\"\"},\"PeriodicalIF\":6.7000,\"publicationDate\":\"2025-01-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Analytical Chemistry\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1021/acs.analchem.4c06405\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Chemistry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1021/acs.analchem.4c06405","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

精氨酸(Arg)参与组织代谢,调节免疫功能;因此,实现精氨酸的检测对于疾病的早期诊断和治疗至关重要。本文采用左旋/右旋碳点(CDs)的蓝色发射和卟啉(L/D-CDs-PP)的红色发射制备了双比例荧光传感器,用于灵敏、便携地检测精氨酸。有趣的是,L-CDs-PP和D-CDs-PP不仅在493和650 nm处表现出双发射峰,而且对Arg的响应模式也不同;因此,它们可以作为双比例荧光传感器,实现对Arg的准确可靠检测,L-CDs-PP的检出限为23.87 μM, D-CDs-PP的检出限为2.39 μM。重要的是,该固态传感器在智能手机平台的支持下成功实现了Arg的双模视觉和便携式检测。此外,L-CDs-PP和D-CDs-PP具有良好的生物相容性和细胞成像能力,可实现细胞和尿液、大鼠血浆生物样品中精氨酸的检测。因此,双比例荧光传感器在分析传感、生物成像、医学诊断等领域具有广阔的应用前景。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Dual Ratiometric Fluorescence Sensors Based on Chiral Carbon Dots for the Sensitive and Specific Detection of Arginine
Arginine (Arg) is involved in tissue metabolism and regulates the immune function; thereby, achieving the detection of Arg is crucial for early diagnosis and treatment of diseases. Herein, dual ratiometric fluorescence sensors were prepared with the blue emission of levorotatory/dextrorotatory carbon dots (CDs) and the red emission of porphyrin (L/D-CDs-PP) for the sensitive and portable detection of Arg. Interestingly, L-CDs-PP and D-CDs-PP displayed not only the dual emission peaks at 493 and 650 nm but also different response modes to Arg; thus, they could serve as dual ratiometric fluorescence sensors to achieve the accurate and reliable detection of Arg, with the detection limit of 23.87 μM for L-CDs-PP and 2.39 μM for D-CDs-PP. Importantly, the solid-state sensors successfully achieved dual-mode visual and portable detection of Arg with the support of a smartphone platform. In addition, L-CDs-PP and D-CDs-PP exhibited excellent biocompatibility and cell imaging capabilities, and they could achieve the detection of Arg in cells and biological samples of urine and rat plasma. Therefore, the dual ratiometric fluorescence sensors exhibited broad application prospects in the fields of analytical sensing, biological imaging, and medical diagnosis.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Analytical Chemistry
Analytical Chemistry 化学-分析化学
CiteScore
12.10
自引率
12.20%
发文量
1949
审稿时长
1.4 months
期刊介绍: Analytical Chemistry, a peer-reviewed research journal, focuses on disseminating new and original knowledge across all branches of analytical chemistry. Fundamental articles may explore general principles of chemical measurement science and need not directly address existing or potential analytical methodology. They can be entirely theoretical or report experimental results. Contributions may cover various phases of analytical operations, including sampling, bioanalysis, electrochemistry, mass spectrometry, microscale and nanoscale systems, environmental analysis, separations, spectroscopy, chemical reactions and selectivity, instrumentation, imaging, surface analysis, and data processing. Papers discussing known analytical methods should present a significant, original application of the method, a notable improvement, or results on an important analyte.
期刊最新文献
Hierarchical Amplification-Interlinked CRISPR-Cas14a Luminescent Biosensor Coupled with Portable Photonic Crystal Biochip-Boosted Time-Delayed Signaling for the Diagnosis of Pediatric Mycoplasma pneumoniae Pneumonia. Robust Metabolomics Data Normalization across Scales and Experimental Designs. A ppb-Level Chloroform Photoacoustic Gas Sensor Based on Omnidirectional Acoustic Sensing with a 3D Microphone Phased Array. Laser Light Scattering-Enhanced Deep Computer Vision Method for the Detection of Trace Mineral Oil in Vegetable Oils. Real-Time Monitoring of APE1 during Cancer Cell Pyroptosis Induced by Electrical Stimulation with DNA Nanoprobes.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1