使用实时组织光学评估预测脉冲场损伤持久性的房颤消融的首次人体试验。

IF 7.9 1区 医学 Q1 CARDIAC & CARDIOVASCULAR SYSTEMS Europace Pub Date : 2025-01-17 DOI:10.1093/europace/euaf009
Raphael P Martins, Giorgi Papiashvili, Askar Sabirov, Sherzod Sabirov, David Herranz, Christophe Bailleul, Atul Verma
{"title":"使用实时组织光学评估预测脉冲场损伤持久性的房颤消融的首次人体试验。","authors":"Raphael P Martins, Giorgi Papiashvili, Askar Sabirov, Sherzod Sabirov, David Herranz, Christophe Bailleul, Atul Verma","doi":"10.1093/europace/euaf009","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Loss of bipolar electrograms immediately after pulsed field ablation (PFA) makes lesion durability assessment challenging.</p><p><strong>Objective: </strong>The aim of this trial (NCT06700226) was to evaluate a novel ablation system that can optically predict lesion durability by detecting structural changes in the tissue during ablation.</p><p><strong>Methods: </strong>Patients with paroxysmal atrial fibrillation underwent pulmonary vein isolation (PVI) using PFA (AblaView®, MedLumics). Using polarization sensitive optical coherence reflectometry (PS-OCR), reflective characteristics of myocardial tissue and visualization of real-time contrast between healthy tissue and ablated tissue using a drop in tissue birefringence (BiR) was assessed. Wide antral PVI was performed using single point irrigated PFA (unipolar, 1800V, 3 trains, 21sec). Remapping was performed at 3 months. Primary efficacy outcome was the ability of PS-OCR to predict lesion durability at 3-month remapping. Serious adverse events were recorded.</p><p><strong>Results: </strong>Ten patients were included. In total, 38/40 PVs could be isolated with the system. The mean drop of BiR was 17.3±11.5%. Dragging across the ablation lines showed a persistent drop in BiR. During the remap procedures (9/10 patients), 15 PVs (41.7%) were found to be electrically reconnected. The mean loss of BiR during the index ablation for durable lesions was 20.9%, while only 10.1% BiR loss was observed during the index ablation for reconnected areas (p<0.001). None of the points with ≥17% loss of birefringence was found to be reconnected.</p><p><strong>Conclusions: </strong>This first in human study supports the use of real-time drop in tissue BiR for lesion assessment during PFA delivery and its procedural safety.</p>","PeriodicalId":11981,"journal":{"name":"Europace","volume":" ","pages":""},"PeriodicalIF":7.9000,"publicationDate":"2025-01-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"First-in-human trial of atrial fibrillation ablation using real time tissue optical assessment to predict pulsed field lesion durability.\",\"authors\":\"Raphael P Martins, Giorgi Papiashvili, Askar Sabirov, Sherzod Sabirov, David Herranz, Christophe Bailleul, Atul Verma\",\"doi\":\"10.1093/europace/euaf009\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Loss of bipolar electrograms immediately after pulsed field ablation (PFA) makes lesion durability assessment challenging.</p><p><strong>Objective: </strong>The aim of this trial (NCT06700226) was to evaluate a novel ablation system that can optically predict lesion durability by detecting structural changes in the tissue during ablation.</p><p><strong>Methods: </strong>Patients with paroxysmal atrial fibrillation underwent pulmonary vein isolation (PVI) using PFA (AblaView®, MedLumics). Using polarization sensitive optical coherence reflectometry (PS-OCR), reflective characteristics of myocardial tissue and visualization of real-time contrast between healthy tissue and ablated tissue using a drop in tissue birefringence (BiR) was assessed. Wide antral PVI was performed using single point irrigated PFA (unipolar, 1800V, 3 trains, 21sec). Remapping was performed at 3 months. Primary efficacy outcome was the ability of PS-OCR to predict lesion durability at 3-month remapping. Serious adverse events were recorded.</p><p><strong>Results: </strong>Ten patients were included. In total, 38/40 PVs could be isolated with the system. The mean drop of BiR was 17.3±11.5%. Dragging across the ablation lines showed a persistent drop in BiR. During the remap procedures (9/10 patients), 15 PVs (41.7%) were found to be electrically reconnected. The mean loss of BiR during the index ablation for durable lesions was 20.9%, while only 10.1% BiR loss was observed during the index ablation for reconnected areas (p<0.001). None of the points with ≥17% loss of birefringence was found to be reconnected.</p><p><strong>Conclusions: </strong>This first in human study supports the use of real-time drop in tissue BiR for lesion assessment during PFA delivery and its procedural safety.</p>\",\"PeriodicalId\":11981,\"journal\":{\"name\":\"Europace\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":7.9000,\"publicationDate\":\"2025-01-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Europace\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1093/europace/euaf009\",\"RegionNum\":1,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Europace","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/europace/euaf009","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

背景:脉冲场消融(PFA)后立即丢失双极电图使得损伤耐久性评估具有挑战性。目的:本试验(NCT06700226)的目的是评估一种新型消融系统,该系统可以通过检测消融过程中组织的结构变化来光学预测病变的持久性。方法:阵发性心房颤动患者采用PFA (AblaView®,MedLumics)进行肺静脉隔离(PVI)。采用偏振敏感光学相干反射仪(PS-OCR),评估心肌组织的反射特性,并利用组织双折射(BiR)的下降来实时显示健康组织和消融组织之间的对比。采用单点灌洗PFA(单极,1800V, 3列,21sec)进行宽窦腔PVI。3个月时进行重新测绘。主要疗效指标是PS-OCR在3个月重测时预测病变持久性的能力。严重不良事件均有记录。结果:纳入10例患者。该系统总共可以分离38/40个pv。BiR平均下降17.3±11.5%。拖过烧蚀线显示BiR持续下降。在重新定位过程中(9/10例患者),发现15个pv(41.7%)电重新连接。持久病灶的指数消融期间BiR的平均损失为20.9%,而在重新连接区域的指数消融期间仅观察到10.1%的BiR损失(结论:这是首次在人类研究中支持使用组织BiR实时下降来评估PFA输送过程中的病变及其程序安全性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
First-in-human trial of atrial fibrillation ablation using real time tissue optical assessment to predict pulsed field lesion durability.

Background: Loss of bipolar electrograms immediately after pulsed field ablation (PFA) makes lesion durability assessment challenging.

Objective: The aim of this trial (NCT06700226) was to evaluate a novel ablation system that can optically predict lesion durability by detecting structural changes in the tissue during ablation.

Methods: Patients with paroxysmal atrial fibrillation underwent pulmonary vein isolation (PVI) using PFA (AblaView®, MedLumics). Using polarization sensitive optical coherence reflectometry (PS-OCR), reflective characteristics of myocardial tissue and visualization of real-time contrast between healthy tissue and ablated tissue using a drop in tissue birefringence (BiR) was assessed. Wide antral PVI was performed using single point irrigated PFA (unipolar, 1800V, 3 trains, 21sec). Remapping was performed at 3 months. Primary efficacy outcome was the ability of PS-OCR to predict lesion durability at 3-month remapping. Serious adverse events were recorded.

Results: Ten patients were included. In total, 38/40 PVs could be isolated with the system. The mean drop of BiR was 17.3±11.5%. Dragging across the ablation lines showed a persistent drop in BiR. During the remap procedures (9/10 patients), 15 PVs (41.7%) were found to be electrically reconnected. The mean loss of BiR during the index ablation for durable lesions was 20.9%, while only 10.1% BiR loss was observed during the index ablation for reconnected areas (p<0.001). None of the points with ≥17% loss of birefringence was found to be reconnected.

Conclusions: This first in human study supports the use of real-time drop in tissue BiR for lesion assessment during PFA delivery and its procedural safety.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Europace
Europace 医学-心血管系统
CiteScore
10.30
自引率
8.20%
发文量
851
审稿时长
3-6 weeks
期刊介绍: EP - Europace - European Journal of Pacing, Arrhythmias and Cardiac Electrophysiology of the European Heart Rhythm Association of the European Society of Cardiology. The journal aims to provide an avenue of communication of top quality European and international original scientific work and reviews in the fields of Arrhythmias, Pacing and Cellular Electrophysiology. The Journal offers the reader a collection of contemporary original peer-reviewed papers, invited papers and editorial comments together with book reviews and correspondence.
期刊最新文献
SCN5A variant type-dependent risk prediction in Brugada syndrome. Lactobacillus gasseri prevents ibrutinib-associated atrial fibrillation through butyrate. Letter to the editor: exercise stress test as a screening tool for pre-excitation. Freeze the clock: earlier catheter ablation for atrial fibrillation delivers better outcomes. Impact of atrial fibrillation diagnosis-to-ablation time on 24-month efficacy and safety outcomes in the Cryo Global Registry.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1