原位酸蚀对不同表面处理的纳米双丙烯酸树脂结构和光学性能的影响

IF 3.2 3区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE Journal of Esthetic and Restorative Dentistry Pub Date : 2025-01-17 DOI:10.1111/jerd.13411
Isabela Dornelas Neves Mendonça, João Pedro Justino de Oliveira Limirio, Thiago Scudeler Foltran, Marcio Campaner, Victor Alves Nascimento, Ana Beatriz de Souza Albergardi, Gabriel Nunes Sampaio, Aldieris Alves Pesqueira
{"title":"原位酸蚀对不同表面处理的纳米双丙烯酸树脂结构和光学性能的影响","authors":"Isabela Dornelas Neves Mendonça, João Pedro Justino de Oliveira Limirio, Thiago Scudeler Foltran, Marcio Campaner, Victor Alves Nascimento, Ana Beatriz de Souza Albergardi, Gabriel Nunes Sampaio, Aldieris Alves Pesqueira","doi":"10.1111/jerd.13411","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To evaluate the influence of in situ acid erosion on the structural and optical properties of nanoparticulate bisacrylic resin with different surface treatments, evaluating surface roughness (Ra), knoop microhardness (KHN), color change (ΔE, ΔL, ΔC, ΔH), contrast (CR) and translucency (TP).</p><p><strong>Methods: </strong>Eighty specimens were made (n = 10 per group) and the following surface treatments were applied: U<sub>P</sub>-unpolished; A<sub>p</sub>-polishing with Astropol rubber tips (Ivoclar); S<sub>B</sub>-Biscover LV surface sealant (Bisco) and S<sub>P</sub>-Palaseal surface sealant (kulzer). For the in situ experiment, 10 volunteers wore an intraoral appliance containing eight specimens (two specimens per experimental group), with only one specimen from each experimental group being subjected to the acid process. They were immersed in 150 mL of cola-based soda (pH = 2.3), 4 × 5 min/day for 14 consecutive days evaluating surface roughness (Ra), knoop microhardness (KHN), color change by CIEDE2000 (ΔE, ΔL, ΔC, ΔH), contrast (CR) and translucency (TP).</p><p><strong>Results: </strong>The S<sub>B</sub> and S<sub>P</sub> groups adopted the lowest Ra values, with a significant difference from the others. The S<sub>B</sub> group had the highest values of KHN and NP the lowest, with a significant difference from the others. The S<sub>P</sub> group had the highest values of ΔE00, being the only one with a significant difference from the others. In all analyses, there was no significant change between the groups without and with acid administration.</p><p><strong>Conclusion: </strong>The surface sealants were able to improve the surface roughness and microhardness of the bisacrylic resin, however, the Palaseal sealant generates unacceptable color change. The acid injection did not significantly influence the properties of the material, regardless of the surface treatment performed.</p>","PeriodicalId":15988,"journal":{"name":"Journal of Esthetic and Restorative Dentistry","volume":" ","pages":""},"PeriodicalIF":3.2000,"publicationDate":"2025-01-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effect of In Situ Acid Erosion on Structural and Optical Properties of Nanoparticulated Bisacrylic Resin With Different Surface Treatments.\",\"authors\":\"Isabela Dornelas Neves Mendonça, João Pedro Justino de Oliveira Limirio, Thiago Scudeler Foltran, Marcio Campaner, Victor Alves Nascimento, Ana Beatriz de Souza Albergardi, Gabriel Nunes Sampaio, Aldieris Alves Pesqueira\",\"doi\":\"10.1111/jerd.13411\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>To evaluate the influence of in situ acid erosion on the structural and optical properties of nanoparticulate bisacrylic resin with different surface treatments, evaluating surface roughness (Ra), knoop microhardness (KHN), color change (ΔE, ΔL, ΔC, ΔH), contrast (CR) and translucency (TP).</p><p><strong>Methods: </strong>Eighty specimens were made (n = 10 per group) and the following surface treatments were applied: U<sub>P</sub>-unpolished; A<sub>p</sub>-polishing with Astropol rubber tips (Ivoclar); S<sub>B</sub>-Biscover LV surface sealant (Bisco) and S<sub>P</sub>-Palaseal surface sealant (kulzer). For the in situ experiment, 10 volunteers wore an intraoral appliance containing eight specimens (two specimens per experimental group), with only one specimen from each experimental group being subjected to the acid process. They were immersed in 150 mL of cola-based soda (pH = 2.3), 4 × 5 min/day for 14 consecutive days evaluating surface roughness (Ra), knoop microhardness (KHN), color change by CIEDE2000 (ΔE, ΔL, ΔC, ΔH), contrast (CR) and translucency (TP).</p><p><strong>Results: </strong>The S<sub>B</sub> and S<sub>P</sub> groups adopted the lowest Ra values, with a significant difference from the others. The S<sub>B</sub> group had the highest values of KHN and NP the lowest, with a significant difference from the others. The S<sub>P</sub> group had the highest values of ΔE00, being the only one with a significant difference from the others. In all analyses, there was no significant change between the groups without and with acid administration.</p><p><strong>Conclusion: </strong>The surface sealants were able to improve the surface roughness and microhardness of the bisacrylic resin, however, the Palaseal sealant generates unacceptable color change. The acid injection did not significantly influence the properties of the material, regardless of the surface treatment performed.</p>\",\"PeriodicalId\":15988,\"journal\":{\"name\":\"Journal of Esthetic and Restorative Dentistry\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":3.2000,\"publicationDate\":\"2025-01-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Esthetic and Restorative Dentistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1111/jerd.13411\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Esthetic and Restorative Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/jerd.13411","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:评价原位酸蚀对不同表面处理的纳米双丙烯酸树脂结构和光学性能的影响,评价表面粗糙度(Ra)、knoop显微硬度(KHN)、颜色变化(ΔE、ΔL、ΔC、ΔH)、对比度(CR)和透光率(TP)。方法:制作80个标本(每组10个),表面处理:up - unpolishing;使用Astropol橡胶头进行ap抛光(Ivoclar);SB-Biscover LV表面密封胶(Bisco)和SP-Palaseal表面密封胶(kulzer)。在原位实验中,10名志愿者佩戴含有8个标本的口腔内矫治器(每个实验组2个标本),每个实验组只有1个标本进行酸处理。将其浸泡在150 mL可乐基苏打(pH = 2.3)中,每天4 × 5分钟,连续14天,评估表面粗糙度(Ra)、knoop显微硬度(KHN)、CIEDE2000颜色变化(ΔE, ΔL, ΔC, ΔH)、对比度(CR)和透明度(TP)。结果:SB和SP组Ra值最低,与其他组差异有统计学意义。SB组KHN值最高,NP值最低,与其他组差异显著。SP组的ΔE00值最高,是唯一与其他组有显著差异的组。在所有的分析中,没有给酸组和给酸组之间没有显著的变化。结论:表面密封剂可以改善双丙烯酸树脂的表面粗糙度和显微硬度,但Palaseal密封剂会产生不可接受的颜色变化。无论进行何种表面处理,注入酸都不会显著影响材料的性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Effect of In Situ Acid Erosion on Structural and Optical Properties of Nanoparticulated Bisacrylic Resin With Different Surface Treatments.

Objective: To evaluate the influence of in situ acid erosion on the structural and optical properties of nanoparticulate bisacrylic resin with different surface treatments, evaluating surface roughness (Ra), knoop microhardness (KHN), color change (ΔE, ΔL, ΔC, ΔH), contrast (CR) and translucency (TP).

Methods: Eighty specimens were made (n = 10 per group) and the following surface treatments were applied: UP-unpolished; Ap-polishing with Astropol rubber tips (Ivoclar); SB-Biscover LV surface sealant (Bisco) and SP-Palaseal surface sealant (kulzer). For the in situ experiment, 10 volunteers wore an intraoral appliance containing eight specimens (two specimens per experimental group), with only one specimen from each experimental group being subjected to the acid process. They were immersed in 150 mL of cola-based soda (pH = 2.3), 4 × 5 min/day for 14 consecutive days evaluating surface roughness (Ra), knoop microhardness (KHN), color change by CIEDE2000 (ΔE, ΔL, ΔC, ΔH), contrast (CR) and translucency (TP).

Results: The SB and SP groups adopted the lowest Ra values, with a significant difference from the others. The SB group had the highest values of KHN and NP the lowest, with a significant difference from the others. The SP group had the highest values of ΔE00, being the only one with a significant difference from the others. In all analyses, there was no significant change between the groups without and with acid administration.

Conclusion: The surface sealants were able to improve the surface roughness and microhardness of the bisacrylic resin, however, the Palaseal sealant generates unacceptable color change. The acid injection did not significantly influence the properties of the material, regardless of the surface treatment performed.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Esthetic and Restorative Dentistry
Journal of Esthetic and Restorative Dentistry 医学-牙科与口腔外科
CiteScore
6.30
自引率
6.20%
发文量
124
审稿时长
>12 weeks
期刊介绍: The Journal of Esthetic and Restorative Dentistry (JERD) is the longest standing peer-reviewed journal devoted solely to advancing the knowledge and practice of esthetic dentistry. Its goal is to provide the very latest evidence-based information in the realm of contemporary interdisciplinary esthetic dentistry through high quality clinical papers, sound research reports and educational features. The range of topics covered in the journal includes: - Interdisciplinary esthetic concepts - Implants - Conservative adhesive restorations - Tooth Whitening - Prosthodontic materials and techniques - Dental materials - Orthodontic, periodontal and endodontic esthetics - Esthetics related research - Innovations in esthetics
期刊最新文献
Minimally Invasive Fixed Prosthodontics: A Narrative Review. The Effect of Plaque Detectors on the Color Stability of Two Types of Restorative Materials. A Twist on Injection Molding: Injecting Conventional Resin Composites. Classification of Scanning Errors of Digital Scans Recorded by Using Intraoral Scanners. Effect of Cervical Margin Relocation With Different Injectable Restorative Materials on Fracture Resistance of Molars Received MOD CAD/CAM Onlay Restorations.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1