{"title":"关于电极排列和其他参数对经皮脊髓直流电刺激应用影响的新证据。","authors":"Andrea Gigliotti, Hugo M Pereira","doi":"10.1152/jn.00441.2024","DOIUrl":null,"url":null,"abstract":"<p><p>Transcutaneous spinal direct current stimulation (TSDCS) has the potential to modulate spinal circuits and induce functional changes in humans. Nevertheless, differences across studies on basic parameters used and obtained metrics represent a confounding factor. Computer simulations are instrumental in improving the application of the TSDCS technique. Their findings allow a better interpretation of the tissue conductivities heterogeneity. Emerging findings indicate the electric field is maximal in the segments located between the electrodes, and that factors such as the depth of the targeted area, and location of the electrodes on low conductive points, such as the spinous processes, may impact the electric field generated in the spinal cord, with consequences for thoracic versus lumbar or cervical applications. Recently, growing attention has been directed toward the importance of the TSDCS reference electrode's position and its influence on the current field properties at the targeted site. This review highlights the influence of dosage, polarity, and electrode position on the variety of TSDCS results in healthy and some clinical populations. Based on the available evidence, we suggest that although the current dosage appears to have a negligible effect, the variety of electrode montages and configurations of TSDCS can significantly impact the electric field distributions and potentially explain the conflicting results of experimental studies. Future human trials should systematically and thoughtfully evaluate the location of TSDCS electrodes based on the targeted neural structures.</p>","PeriodicalId":16563,"journal":{"name":"Journal of neurophysiology","volume":" ","pages":"709-721"},"PeriodicalIF":2.1000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Emerging evidence on the effects of electrode arrangements and other parameters on the application of transcutaneous spinal direct current stimulation.\",\"authors\":\"Andrea Gigliotti, Hugo M Pereira\",\"doi\":\"10.1152/jn.00441.2024\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Transcutaneous spinal direct current stimulation (TSDCS) has the potential to modulate spinal circuits and induce functional changes in humans. Nevertheless, differences across studies on basic parameters used and obtained metrics represent a confounding factor. Computer simulations are instrumental in improving the application of the TSDCS technique. Their findings allow a better interpretation of the tissue conductivities heterogeneity. Emerging findings indicate the electric field is maximal in the segments located between the electrodes, and that factors such as the depth of the targeted area, and location of the electrodes on low conductive points, such as the spinous processes, may impact the electric field generated in the spinal cord, with consequences for thoracic versus lumbar or cervical applications. Recently, growing attention has been directed toward the importance of the TSDCS reference electrode's position and its influence on the current field properties at the targeted site. This review highlights the influence of dosage, polarity, and electrode position on the variety of TSDCS results in healthy and some clinical populations. Based on the available evidence, we suggest that although the current dosage appears to have a negligible effect, the variety of electrode montages and configurations of TSDCS can significantly impact the electric field distributions and potentially explain the conflicting results of experimental studies. Future human trials should systematically and thoughtfully evaluate the location of TSDCS electrodes based on the targeted neural structures.</p>\",\"PeriodicalId\":16563,\"journal\":{\"name\":\"Journal of neurophysiology\",\"volume\":\" \",\"pages\":\"709-721\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2025-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of neurophysiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1152/jn.00441.2024\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/1/17 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"NEUROSCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of neurophysiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1152/jn.00441.2024","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/17 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"NEUROSCIENCES","Score":null,"Total":0}
Emerging evidence on the effects of electrode arrangements and other parameters on the application of transcutaneous spinal direct current stimulation.
Transcutaneous spinal direct current stimulation (TSDCS) has the potential to modulate spinal circuits and induce functional changes in humans. Nevertheless, differences across studies on basic parameters used and obtained metrics represent a confounding factor. Computer simulations are instrumental in improving the application of the TSDCS technique. Their findings allow a better interpretation of the tissue conductivities heterogeneity. Emerging findings indicate the electric field is maximal in the segments located between the electrodes, and that factors such as the depth of the targeted area, and location of the electrodes on low conductive points, such as the spinous processes, may impact the electric field generated in the spinal cord, with consequences for thoracic versus lumbar or cervical applications. Recently, growing attention has been directed toward the importance of the TSDCS reference electrode's position and its influence on the current field properties at the targeted site. This review highlights the influence of dosage, polarity, and electrode position on the variety of TSDCS results in healthy and some clinical populations. Based on the available evidence, we suggest that although the current dosage appears to have a negligible effect, the variety of electrode montages and configurations of TSDCS can significantly impact the electric field distributions and potentially explain the conflicting results of experimental studies. Future human trials should systematically and thoughtfully evaluate the location of TSDCS electrodes based on the targeted neural structures.
期刊介绍:
The Journal of Neurophysiology publishes original articles on the function of the nervous system. All levels of function are included, from the membrane and cell to systems and behavior. Experimental approaches include molecular neurobiology, cell culture and slice preparations, membrane physiology, developmental neurobiology, functional neuroanatomy, neurochemistry, neuropharmacology, systems electrophysiology, imaging and mapping techniques, and behavioral analysis. Experimental preparations may be invertebrate or vertebrate species, including humans. Theoretical studies are acceptable if they are tied closely to the interpretation of experimental data and elucidate principles of broad interest.