质子共振增强CEST成像和移位交换(精确)家族的射频脉冲形状的CEST MRI。

IF 3 3区 医学 Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Magnetic Resonance in Medicine Pub Date : 2025-01-20 DOI:10.1002/mrm.30410
Zinia Mohanta, Julia Stabinska, Assaf A Gilad, Peter B Barker, Michael T McMahon
{"title":"质子共振增强CEST成像和移位交换(精确)家族的射频脉冲形状的CEST MRI。","authors":"Zinia Mohanta, Julia Stabinska, Assaf A Gilad, Peter B Barker, Michael T McMahon","doi":"10.1002/mrm.30410","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To optimize a 100 ms pulse for producing CEST MRI contrast and evaluate in mice.</p><p><strong>Methods: </strong>A gradient ascent algorithm was employed to generate a family of 100 point, 100 ms pulses for use in CEST pulse trains (proton resonance enhancement for CEST imaging and shift exchange). Gradient ascent optimizations were performed for exchange rates = 500, 1500, 2500, 3500, and 4500 s<sup>-1</sup>; and labile proton offsets (Δω) = 9.6, 7.8, 4.2, and 2.0 ppm. Seven proton resonance enhancement for CEST imaging and shift exchange pulse shapes were tested on an 11.7 T scanner using a phantom containing three representative CEST agents with peak saturation B<sub>1,peak</sub> = 4 μT. The pulse producing the most contrast in phantoms was then evaluated for CEST MRI pH mapping of the kidneys in healthy mice after iopamidol administration.</p><p><strong>Results: </strong>The most promising pulse in terms of contrast performance across all three phantoms was the 9.6 ppm, 2500 s<sup>-1</sup> optimized pulse with ˜2.7 × increase in asymmetric magnetization transfer ratio (MTR<sub>asym</sub>) over Gaussian, and ˜ 1.3 times over Fermi pulses for the same B<sub>1,peak</sub> = 4 μT. This pulse also displayed a large improvement in contrast over the Gaussian pulse after administration of iopamidol in live mice.</p><p><strong>Conclusion: </strong>A new 100-ms pulse was developed based on gradient ascent optimizations, which produced better contrast compared to standard Gaussian and Fermi pulses in phantoms. This shape also showed a substantial improvement for CEST MRI pH mapping in live mice over the Gaussian shape and appears promising for a wide range of CEST applications.</p>","PeriodicalId":18065,"journal":{"name":"Magnetic Resonance in Medicine","volume":" ","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2025-01-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The proton resonance enhancement for CEST imaging and shift exchange (PRECISE) family of RF pulse shapes for CEST MRI.\",\"authors\":\"Zinia Mohanta, Julia Stabinska, Assaf A Gilad, Peter B Barker, Michael T McMahon\",\"doi\":\"10.1002/mrm.30410\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To optimize a 100 ms pulse for producing CEST MRI contrast and evaluate in mice.</p><p><strong>Methods: </strong>A gradient ascent algorithm was employed to generate a family of 100 point, 100 ms pulses for use in CEST pulse trains (proton resonance enhancement for CEST imaging and shift exchange). Gradient ascent optimizations were performed for exchange rates = 500, 1500, 2500, 3500, and 4500 s<sup>-1</sup>; and labile proton offsets (Δω) = 9.6, 7.8, 4.2, and 2.0 ppm. Seven proton resonance enhancement for CEST imaging and shift exchange pulse shapes were tested on an 11.7 T scanner using a phantom containing three representative CEST agents with peak saturation B<sub>1,peak</sub> = 4 μT. The pulse producing the most contrast in phantoms was then evaluated for CEST MRI pH mapping of the kidneys in healthy mice after iopamidol administration.</p><p><strong>Results: </strong>The most promising pulse in terms of contrast performance across all three phantoms was the 9.6 ppm, 2500 s<sup>-1</sup> optimized pulse with ˜2.7 × increase in asymmetric magnetization transfer ratio (MTR<sub>asym</sub>) over Gaussian, and ˜ 1.3 times over Fermi pulses for the same B<sub>1,peak</sub> = 4 μT. This pulse also displayed a large improvement in contrast over the Gaussian pulse after administration of iopamidol in live mice.</p><p><strong>Conclusion: </strong>A new 100-ms pulse was developed based on gradient ascent optimizations, which produced better contrast compared to standard Gaussian and Fermi pulses in phantoms. This shape also showed a substantial improvement for CEST MRI pH mapping in live mice over the Gaussian shape and appears promising for a wide range of CEST applications.</p>\",\"PeriodicalId\":18065,\"journal\":{\"name\":\"Magnetic Resonance in Medicine\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2025-01-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Magnetic Resonance in Medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1002/mrm.30410\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Magnetic Resonance in Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/mrm.30410","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

目的:优化100 ms脉冲产生小鼠CEST MRI对比和评价。方法:采用梯度上升算法生成100个点,100 ms脉冲,用于CEST脉冲序列(质子共振增强CEST成像和移位交换)。在汇率= 500、1500、2500、3500和4500 s-1时进行梯度上升优化;不稳定质子偏移量(Δω) = 9.6, 7.8, 4.2和2.0 ppm。在11.7 T扫描仪上,使用含有3种代表性CEST试剂的幻体,测试了7种质子共振增强CEST成像和移位交换脉冲形状,峰饱和度为B1,峰= 4 μT。在幻象中产生最大对比度的脉冲,然后在健康小鼠给药后进行CEST MRI肾脏pH映射评估。结果:在所有三种模态的对比性能方面,最有希望的脉冲是9.6 ppm, 2500 s-1的优化脉冲,在相同的B1下,不对称磁化传递比(MTRasym)比高斯脉冲增加约2.7倍,比费米脉冲增加约1.3倍,峰值= 4 μT。在活体小鼠中给予iopamidol后,该脉冲也比高斯脉冲有了很大的改善。结论:基于梯度上升优化设计了一种新的100 ms脉冲,与标准高斯脉冲和费米脉冲相比,该脉冲在幻象中具有更好的对比度。与高斯形状相比,这种形状在活体小鼠的CEST MRI pH映射方面也有了实质性的改进,并有望在广泛的CEST应用中得到应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The proton resonance enhancement for CEST imaging and shift exchange (PRECISE) family of RF pulse shapes for CEST MRI.

Purpose: To optimize a 100 ms pulse for producing CEST MRI contrast and evaluate in mice.

Methods: A gradient ascent algorithm was employed to generate a family of 100 point, 100 ms pulses for use in CEST pulse trains (proton resonance enhancement for CEST imaging and shift exchange). Gradient ascent optimizations were performed for exchange rates = 500, 1500, 2500, 3500, and 4500 s-1; and labile proton offsets (Δω) = 9.6, 7.8, 4.2, and 2.0 ppm. Seven proton resonance enhancement for CEST imaging and shift exchange pulse shapes were tested on an 11.7 T scanner using a phantom containing three representative CEST agents with peak saturation B1,peak = 4 μT. The pulse producing the most contrast in phantoms was then evaluated for CEST MRI pH mapping of the kidneys in healthy mice after iopamidol administration.

Results: The most promising pulse in terms of contrast performance across all three phantoms was the 9.6 ppm, 2500 s-1 optimized pulse with ˜2.7 × increase in asymmetric magnetization transfer ratio (MTRasym) over Gaussian, and ˜ 1.3 times over Fermi pulses for the same B1,peak = 4 μT. This pulse also displayed a large improvement in contrast over the Gaussian pulse after administration of iopamidol in live mice.

Conclusion: A new 100-ms pulse was developed based on gradient ascent optimizations, which produced better contrast compared to standard Gaussian and Fermi pulses in phantoms. This shape also showed a substantial improvement for CEST MRI pH mapping in live mice over the Gaussian shape and appears promising for a wide range of CEST applications.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
6.70
自引率
24.20%
发文量
376
审稿时长
2-4 weeks
期刊介绍: Magnetic Resonance in Medicine (Magn Reson Med) is an international journal devoted to the publication of original investigations concerned with all aspects of the development and use of nuclear magnetic resonance and electron paramagnetic resonance techniques for medical applications. Reports of original investigations in the areas of mathematics, computing, engineering, physics, biophysics, chemistry, biochemistry, and physiology directly relevant to magnetic resonance will be accepted, as well as methodology-oriented clinical studies.
期刊最新文献
Considerations and recommendations from the ISMRM diffusion study group for preclinical diffusion MRI: Part 1: In vivo small-animal imaging. Considerations and recommendations from the ISMRM Diffusion Study Group for preclinical diffusion MRI: Part 3-Ex vivo imaging: Data processing, comparisons with microscopy, and tractography. On the RF safety of titanium mesh head implants in 7 T MRI systems: an investigation. 3D joint T1/T1 ρ/T2 mapping and water-fat imaging for contrast-agent free myocardial tissue characterization at 1.5T. Whole liver phase-based R2 mapping in liver iron overload within a breath-hold.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1