趋磁细菌(MTB)对含铬地表水超滤处理膜污染控制的影响。

IF 2.5 4区 环境科学与生态学 Q3 ENGINEERING, ENVIRONMENTAL Water Science and Technology Pub Date : 2025-01-01 Epub Date: 2024-12-18 DOI:10.2166/wst.2024.400
Shuailiang Lu, Guicai Liu, Yingjie Dou, Zhengzhou Zhang, Zhiyong Zhou, Kang Xie
{"title":"趋磁细菌(MTB)对含铬地表水超滤处理膜污染控制的影响。","authors":"Shuailiang Lu, Guicai Liu, Yingjie Dou, Zhengzhou Zhang, Zhiyong Zhou, Kang Xie","doi":"10.2166/wst.2024.400","DOIUrl":null,"url":null,"abstract":"<p><p>Ultrafiltration membranes are widely used in the treatment of surface water. However, membrane fouling is a core issue that needs to be addressed in its application. Magnetotactic bacteria (MTB) show early film-forming and magnetotactic behaviour in the presence of external magnetic fields. The objective of this study was to alleviate membrane fouling in ultrafiltration membranes using MTB, which can prioritise film formation and show directional movement under external magnetic fields. The concentration of Cr<sup>6+</sup> in the water was 10 mg/L, and the dosage of MTB was 10 mg/L. Results show that the transmembrane pressure of the ultrafiltration membrane decreased by 5 kPa following the application of a magnetic field of 33.71 mT for a period of 90 min, and the membrane fouling could therefore be effectively controlled. With the addition of MTB, the average removal of Cr<sup>6+</sup> from water by the ultrafiltration system was 20.10%, which was 14.56% higher than that of the conventional ultrafiltration system. The average removal of chromaticity was 20.13%, which was 10% higher than that achieved by the conventional ultrafiltration system. Furthermore, MTB progressively developed into the predominant flora during the operational phase, thereby enhancing the efficiency of the ultrafiltration system.</p>","PeriodicalId":23653,"journal":{"name":"Water Science and Technology","volume":"91 1","pages":"40-55"},"PeriodicalIF":2.5000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effects of magnetotactic bacteria (MTB) on membrane fouling control in an ultrafiltration treatment of chromium-containing surface water.\",\"authors\":\"Shuailiang Lu, Guicai Liu, Yingjie Dou, Zhengzhou Zhang, Zhiyong Zhou, Kang Xie\",\"doi\":\"10.2166/wst.2024.400\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Ultrafiltration membranes are widely used in the treatment of surface water. However, membrane fouling is a core issue that needs to be addressed in its application. Magnetotactic bacteria (MTB) show early film-forming and magnetotactic behaviour in the presence of external magnetic fields. The objective of this study was to alleviate membrane fouling in ultrafiltration membranes using MTB, which can prioritise film formation and show directional movement under external magnetic fields. The concentration of Cr<sup>6+</sup> in the water was 10 mg/L, and the dosage of MTB was 10 mg/L. Results show that the transmembrane pressure of the ultrafiltration membrane decreased by 5 kPa following the application of a magnetic field of 33.71 mT for a period of 90 min, and the membrane fouling could therefore be effectively controlled. With the addition of MTB, the average removal of Cr<sup>6+</sup> from water by the ultrafiltration system was 20.10%, which was 14.56% higher than that of the conventional ultrafiltration system. The average removal of chromaticity was 20.13%, which was 10% higher than that achieved by the conventional ultrafiltration system. Furthermore, MTB progressively developed into the predominant flora during the operational phase, thereby enhancing the efficiency of the ultrafiltration system.</p>\",\"PeriodicalId\":23653,\"journal\":{\"name\":\"Water Science and Technology\",\"volume\":\"91 1\",\"pages\":\"40-55\"},\"PeriodicalIF\":2.5000,\"publicationDate\":\"2025-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Water Science and Technology\",\"FirstCategoryId\":\"93\",\"ListUrlMain\":\"https://doi.org/10.2166/wst.2024.400\",\"RegionNum\":4,\"RegionCategory\":\"环境科学与生态学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/12/18 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, ENVIRONMENTAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Water Science and Technology","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.2166/wst.2024.400","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/12/18 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ENGINEERING, ENVIRONMENTAL","Score":null,"Total":0}
引用次数: 0

摘要

超滤膜在地表水处理中有着广泛的应用。然而,膜污染是其应用中需要解决的核心问题。趋磁细菌(MTB)在外加磁场作用下表现出早期成膜和趋磁行为。本研究的目的是利用MTB减轻超滤膜中的膜污染,MTB可以优先成膜并在外加磁场下表现出定向运动。水中Cr6+浓度为10 mg/L, MTB用量为10 mg/L。结果表明:在33.71 mT的磁场作用90 min后,超滤膜的跨膜压力降低了5 kPa,膜污染得到有效控制。添加MTB后,超滤系统对水中Cr6+的平均去除率为20.10%,比常规超滤系统提高了14.56%。平均色度去除率为20.13%,比常规超滤系统的去除率提高10%。此外,MTB在操作阶段逐渐发展成为优势菌群,从而提高了超滤系统的效率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Effects of magnetotactic bacteria (MTB) on membrane fouling control in an ultrafiltration treatment of chromium-containing surface water.

Ultrafiltration membranes are widely used in the treatment of surface water. However, membrane fouling is a core issue that needs to be addressed in its application. Magnetotactic bacteria (MTB) show early film-forming and magnetotactic behaviour in the presence of external magnetic fields. The objective of this study was to alleviate membrane fouling in ultrafiltration membranes using MTB, which can prioritise film formation and show directional movement under external magnetic fields. The concentration of Cr6+ in the water was 10 mg/L, and the dosage of MTB was 10 mg/L. Results show that the transmembrane pressure of the ultrafiltration membrane decreased by 5 kPa following the application of a magnetic field of 33.71 mT for a period of 90 min, and the membrane fouling could therefore be effectively controlled. With the addition of MTB, the average removal of Cr6+ from water by the ultrafiltration system was 20.10%, which was 14.56% higher than that of the conventional ultrafiltration system. The average removal of chromaticity was 20.13%, which was 10% higher than that achieved by the conventional ultrafiltration system. Furthermore, MTB progressively developed into the predominant flora during the operational phase, thereby enhancing the efficiency of the ultrafiltration system.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Water Science and Technology
Water Science and Technology 环境科学-工程:环境
CiteScore
4.90
自引率
3.70%
发文量
366
审稿时长
4.4 months
期刊介绍: Water Science and Technology publishes peer-reviewed papers on all aspects of the science and technology of water and wastewater. Papers are selected by a rigorous peer review procedure with the aim of rapid and wide dissemination of research results, development and application of new techniques, and related managerial and policy issues. Scientists, engineers, consultants, managers and policy-makers will find this journal essential as a permanent record of progress of research activities and their practical applications.
期刊最新文献
Optimization of detention ponds for urban stormwater runoff and pollution control in multiple catchments system with analytical probabilistic models and particle swarm. Optimization of urban stormwater systems: a multi-criteria approach to sustainable and cost-effective LID implementation. Polyacrylic acid-based nanoplastics used in cosmetics: a study of biodegradability and effects on heterotrophic and nitrifying microorganisms in the activated sludge. Polyphenol extraction from industrial water by-products: a case study of the ULTIMATE project in the fruit processing industry. Antimicrobial activity of immobilized mycocins in sodium alginate on fecal coliforms.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1