永久左束分支区DF-4除颤器导联植入-可行性,程序注意事项,安全性和随访。

IF 2.4 3区 医学 Q2 CARDIAC & CARDIOVASCULAR SYSTEMS Journal of Cardiovascular Electrophysiology Pub Date : 2025-01-24 DOI:10.1111/jce.16585
Anindya Ghosh, Chenni S. Sriram, Nibin Manu, Mullasari Ajit Sankaradas, Gaurav M. Upadhyay, Ulhas M. Pandurangi
{"title":"永久左束分支区DF-4除颤器导联植入-可行性,程序注意事项,安全性和随访。","authors":"Anindya Ghosh,&nbsp;Chenni S. Sriram,&nbsp;Nibin Manu,&nbsp;Mullasari Ajit Sankaradas,&nbsp;Gaurav M. Upadhyay,&nbsp;Ulhas M. Pandurangi","doi":"10.1111/jce.16585","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Introduction</h3>\n \n <p>Permanent implantation of a DF-4 implantable cardiac defibrillator (ICD) lead in the left bundle branch area (LBBA-ICD) is the next paradigm in amalgamating cardiac resynchronization therapy (CRT) and defibrillation. We systematically investigated feasibility/success rate, procedural caveats, and complications associated with a permanent DF-4 LBBA ICD implant and pertinent data at short-term follow-up.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>We prospectively attempted implantation of 7 Fr Durata (Abbott, Chicago, IL, USA) single coil DF-4 ICD lead at the LBBA using a fixed-curve non-deflectable CPS locator delivery sheath. Standard criteria defined LBBA capture. Relevant sensing/pacing, defibrillation, radiographic, and echocardiographic parameters testing were recorded at implant, discharge and 5-month follow-up.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>We enrolled 12 consecutive cardiac device-naïve patients (median age 67.5 years, male 91.7%, median LVEF 30%, median septal thickness 9 mm, median QRS duration 140 ms, class I CRT indication 58.3%, primary prevention ICD indication 75%). Minor complications (two transeptal perforations and one micro-dislodgment) were noted in 3/12 (25%) patients. Successful permanent LBBA ICD implant with adequate sensing/pacing was achieved in 9/12 (75%) subjects. Sustained ventricular fibrillation (VF) was inducible in 7/9 patients with successful implants with effective sensing and defibrillation in all. Follow-up device-related and echocardiographic parameters were similar at discharge and 5-month follow-up.</p>\n </section>\n \n <section>\n \n <h3> Conclusion</h3>\n \n <p>Permanent DF-4 LBBA ICD implant is feasible and successful in 75% of patients with an indication for ICD. With dedicated toolkits, higher volumes, and an obligate learning curve, the higher-than-expected frequency (25%) of minor complications may be ameliorated. Short-term data regarding lead and selected RV parameters remained favorable.</p>\n </section>\n </div>","PeriodicalId":15178,"journal":{"name":"Journal of Cardiovascular Electrophysiology","volume":"36 3","pages":"650-662"},"PeriodicalIF":2.4000,"publicationDate":"2025-01-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Permanent Left Bundle Branch Area DF-4 Defibrillator Lead Implantation—Feasibility, Procedural Caveats, Safety, and Follow-Up\",\"authors\":\"Anindya Ghosh,&nbsp;Chenni S. Sriram,&nbsp;Nibin Manu,&nbsp;Mullasari Ajit Sankaradas,&nbsp;Gaurav M. Upadhyay,&nbsp;Ulhas M. Pandurangi\",\"doi\":\"10.1111/jce.16585\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n \\n <section>\\n \\n <h3> Introduction</h3>\\n \\n <p>Permanent implantation of a DF-4 implantable cardiac defibrillator (ICD) lead in the left bundle branch area (LBBA-ICD) is the next paradigm in amalgamating cardiac resynchronization therapy (CRT) and defibrillation. We systematically investigated feasibility/success rate, procedural caveats, and complications associated with a permanent DF-4 LBBA ICD implant and pertinent data at short-term follow-up.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Methods</h3>\\n \\n <p>We prospectively attempted implantation of 7 Fr Durata (Abbott, Chicago, IL, USA) single coil DF-4 ICD lead at the LBBA using a fixed-curve non-deflectable CPS locator delivery sheath. Standard criteria defined LBBA capture. Relevant sensing/pacing, defibrillation, radiographic, and echocardiographic parameters testing were recorded at implant, discharge and 5-month follow-up.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Results</h3>\\n \\n <p>We enrolled 12 consecutive cardiac device-naïve patients (median age 67.5 years, male 91.7%, median LVEF 30%, median septal thickness 9 mm, median QRS duration 140 ms, class I CRT indication 58.3%, primary prevention ICD indication 75%). Minor complications (two transeptal perforations and one micro-dislodgment) were noted in 3/12 (25%) patients. Successful permanent LBBA ICD implant with adequate sensing/pacing was achieved in 9/12 (75%) subjects. Sustained ventricular fibrillation (VF) was inducible in 7/9 patients with successful implants with effective sensing and defibrillation in all. Follow-up device-related and echocardiographic parameters were similar at discharge and 5-month follow-up.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Conclusion</h3>\\n \\n <p>Permanent DF-4 LBBA ICD implant is feasible and successful in 75% of patients with an indication for ICD. With dedicated toolkits, higher volumes, and an obligate learning curve, the higher-than-expected frequency (25%) of minor complications may be ameliorated. Short-term data regarding lead and selected RV parameters remained favorable.</p>\\n </section>\\n </div>\",\"PeriodicalId\":15178,\"journal\":{\"name\":\"Journal of Cardiovascular Electrophysiology\",\"volume\":\"36 3\",\"pages\":\"650-662\"},\"PeriodicalIF\":2.4000,\"publicationDate\":\"2025-01-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Cardiovascular Electrophysiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1111/jce.16585\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Cardiovascular Electrophysiology","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/jce.16585","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

导论:在左束分支区(LBBA-ICD)永久植入DF-4植入式心脏除颤器(ICD)是合并心脏再同步化治疗(CRT)和除颤的下一个范例。我们系统地调查了DF-4 LBBA ICD植入术的可行性/成功率、手术注意事项和并发症以及短期随访的相关数据。方法:我们前瞻性地尝试在LBBA植入7 Fr Durata (Abbott, Chicago, IL, USA)单线圈DF-4 ICD引线,使用固定曲线不可偏转的CPS定位器递送护套。标准标准定义了LBBA捕获。在植入、出院和5个月随访时记录相关的传感/起搏、除颤、x线摄影和超声心动图参数测试。结果:我们连续入组了12例心脏device-naïve患者(中位年龄67.5岁,男性91.7%,中位LVEF 30%,中位间隔厚度9 mm,中位QRS持续时间140 ms, I类CRT适应症58.3%,一级预防ICD适应症75%)。3/12(25%)的患者出现轻微并发症(2例跨隔膜穿孔和1例微脱位)。在9/12(75%)的受试者中成功植入具有适当传感/起搏的永久性LBBA ICD。9例植入成功的患者中有7例可诱发持续性心室颤动(VF),所有患者均有有效的感应和除颤。出院时和随访5个月时,随访器械相关参数和超声心动图参数相似。结论:永久DF-4 LBBA ICD种植体在75%有ICD指征的患者中是可行和成功的。有了专门的工具包、更大的容量和专门的学习曲线,小并发症的高预期频率(25%)可能会得到改善。关于导联和选择的RV参数的短期数据仍然是有利的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Permanent Left Bundle Branch Area DF-4 Defibrillator Lead Implantation—Feasibility, Procedural Caveats, Safety, and Follow-Up

Introduction

Permanent implantation of a DF-4 implantable cardiac defibrillator (ICD) lead in the left bundle branch area (LBBA-ICD) is the next paradigm in amalgamating cardiac resynchronization therapy (CRT) and defibrillation. We systematically investigated feasibility/success rate, procedural caveats, and complications associated with a permanent DF-4 LBBA ICD implant and pertinent data at short-term follow-up.

Methods

We prospectively attempted implantation of 7 Fr Durata (Abbott, Chicago, IL, USA) single coil DF-4 ICD lead at the LBBA using a fixed-curve non-deflectable CPS locator delivery sheath. Standard criteria defined LBBA capture. Relevant sensing/pacing, defibrillation, radiographic, and echocardiographic parameters testing were recorded at implant, discharge and 5-month follow-up.

Results

We enrolled 12 consecutive cardiac device-naïve patients (median age 67.5 years, male 91.7%, median LVEF 30%, median septal thickness 9 mm, median QRS duration 140 ms, class I CRT indication 58.3%, primary prevention ICD indication 75%). Minor complications (two transeptal perforations and one micro-dislodgment) were noted in 3/12 (25%) patients. Successful permanent LBBA ICD implant with adequate sensing/pacing was achieved in 9/12 (75%) subjects. Sustained ventricular fibrillation (VF) was inducible in 7/9 patients with successful implants with effective sensing and defibrillation in all. Follow-up device-related and echocardiographic parameters were similar at discharge and 5-month follow-up.

Conclusion

Permanent DF-4 LBBA ICD implant is feasible and successful in 75% of patients with an indication for ICD. With dedicated toolkits, higher volumes, and an obligate learning curve, the higher-than-expected frequency (25%) of minor complications may be ameliorated. Short-term data regarding lead and selected RV parameters remained favorable.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.20
自引率
14.80%
发文量
433
审稿时长
3-6 weeks
期刊介绍: Journal of Cardiovascular Electrophysiology (JCE) keeps its readership well informed of the latest developments in the study and management of arrhythmic disorders. Edited by Bradley P. Knight, M.D., and a distinguished international editorial board, JCE is the leading journal devoted to the study of the electrophysiology of the heart.
期刊最新文献
An Unexpected Encounter: When a Novel Device Algorithm Meets a Novel Ablation System. Association of Diagnostic Code Priority With Identification of True Cardiac Arrest in Patients Presenting to the Emergency Department. Early Bleeding Risk After DOAC Initiation With Concomitant Amiodarone in Older Adults With Atrial Fibrillation. Development and Validation of the LIFE-5S Score for Predicting 5-Year Mortality After Transvenous Lead Extraction. Atrial Fibrosis Imaging: Correlation of Late Gadolinium Enhancement Magnetic Resonance Imaging With High-Definition Voltage Electroanatomical Mapping Across Different Thresholds.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1