增加极性有机化学综合样品处理方法的化学覆盖、准确性和可重复性。

IF 4.1 2区 化学 Q1 BIOCHEMICAL RESEARCH METHODS Analytical and Bioanalytical Chemistry Pub Date : 2025-02-01 DOI:10.1007/s00216-025-05746-x
Matteo Baglietto, Henry MacKeown, Barbara Benedetti, Marina Di Carro, Emanuele Magi
{"title":"增加极性有机化学综合样品处理方法的化学覆盖、准确性和可重复性。","authors":"Matteo Baglietto,&nbsp;Henry MacKeown,&nbsp;Barbara Benedetti,&nbsp;Marina Di Carro,&nbsp;Emanuele Magi","doi":"10.1007/s00216-025-05746-x","DOIUrl":null,"url":null,"abstract":"<div><p>Despite their diffusion in research studies, passive samplers are rarely used in regulatory applications. To expand the employment of passive samplers in regulatory environmental studies, standardized procedures for processing each sampler type should be proposed and accepted, but currently, each study develops its own protocol based on previous knowledge and specific needs. In this work, six identical polar organic chemical integrative samplers in seawater were deployed to understand the importance of the sorbent transfer method prior to the elution step. A common “wet transfer” with ultra-pure water was compared to a less diffused “dry-transfer,” assessing recoveries and matrix effects of 38 target compounds of emerging concern, including polar pesticides, recreational and food-related substances, pharmaceuticals, industrial additives, and ultra-violet (UV) filters. The dry-transfer procedure generally allowed better recoveries, especially for the more polar compounds, without affecting matrix effects (which remained in the range 40–130%). Along with the recovery assessment, the analysis of the non-spiked sorbent extracts revealed traces of many of the targeted emerging contaminants, quantifying perfluorooctanoic acid, UV-filters, carbamazepine, diclofenac, and triclosan. Furthermore, other compounds were found below their limits of quantitation. Ten analytes were detected only in the extracts of the dry-transferred passive samplers, highlighting the importance of applying this protocol, especially when dealing with polar compounds. This refined processing method, therefore, permits a more standardized and reproducible strategy, at the same time enlarging the set of analytes which could be detected and quantified.</p><h3>Graphical abstract</h3>\n<div><figure><div><div><picture><source><img></source></picture></div></div></figure></div></div>","PeriodicalId":462,"journal":{"name":"Analytical and Bioanalytical Chemistry","volume":"417 8","pages":"1567 - 1580"},"PeriodicalIF":4.1000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11876234/pdf/","citationCount":"0","resultStr":"{\"title\":\"Increasing chemical coverage, accuracy, and reproducibility of the processing method for polar organic chemical integrative samplers\",\"authors\":\"Matteo Baglietto,&nbsp;Henry MacKeown,&nbsp;Barbara Benedetti,&nbsp;Marina Di Carro,&nbsp;Emanuele Magi\",\"doi\":\"10.1007/s00216-025-05746-x\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Despite their diffusion in research studies, passive samplers are rarely used in regulatory applications. To expand the employment of passive samplers in regulatory environmental studies, standardized procedures for processing each sampler type should be proposed and accepted, but currently, each study develops its own protocol based on previous knowledge and specific needs. In this work, six identical polar organic chemical integrative samplers in seawater were deployed to understand the importance of the sorbent transfer method prior to the elution step. A common “wet transfer” with ultra-pure water was compared to a less diffused “dry-transfer,” assessing recoveries and matrix effects of 38 target compounds of emerging concern, including polar pesticides, recreational and food-related substances, pharmaceuticals, industrial additives, and ultra-violet (UV) filters. The dry-transfer procedure generally allowed better recoveries, especially for the more polar compounds, without affecting matrix effects (which remained in the range 40–130%). Along with the recovery assessment, the analysis of the non-spiked sorbent extracts revealed traces of many of the targeted emerging contaminants, quantifying perfluorooctanoic acid, UV-filters, carbamazepine, diclofenac, and triclosan. Furthermore, other compounds were found below their limits of quantitation. Ten analytes were detected only in the extracts of the dry-transferred passive samplers, highlighting the importance of applying this protocol, especially when dealing with polar compounds. This refined processing method, therefore, permits a more standardized and reproducible strategy, at the same time enlarging the set of analytes which could be detected and quantified.</p><h3>Graphical abstract</h3>\\n<div><figure><div><div><picture><source><img></source></picture></div></div></figure></div></div>\",\"PeriodicalId\":462,\"journal\":{\"name\":\"Analytical and Bioanalytical Chemistry\",\"volume\":\"417 8\",\"pages\":\"1567 - 1580\"},\"PeriodicalIF\":4.1000,\"publicationDate\":\"2025-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11876234/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Analytical and Bioanalytical Chemistry\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://link.springer.com/article/10.1007/s00216-025-05746-x\",\"RegionNum\":2,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical and Bioanalytical Chemistry","FirstCategoryId":"92","ListUrlMain":"https://link.springer.com/article/10.1007/s00216-025-05746-x","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

摘要

尽管它们在研究中得到了广泛应用,但在监管应用中很少使用被动采样器。为了在监管环境研究中扩大被动采样器的使用,应该提出和接受处理每种采样器类型的标准化程序,但目前,每项研究都根据以前的知识和具体需要制定自己的方案。在这项工作中,在海水中部署了六个相同的极性有机化学综合采样器,以了解在洗脱步骤之前吸附剂转移方法的重要性。用超纯水进行常见的“湿转移”与较少扩散的“干转移”进行了比较,评估了38种新关注的目标化合物的回收率和基质效应,包括极性杀虫剂、娱乐和食品相关物质、药品、工业添加剂和紫外线(UV)过滤器。干转移过程通常允许更好的回收率,特别是对于极性更强的化合物,而不影响基质效应(保持在40-130%的范围内)。在进行回收率评估的同时,对非加标吸附剂提取物的分析发现了许多目标新出现污染物的痕迹,定量分析了全氟辛酸、紫外线过滤器、卡马西平、双氯芬酸和三氯生。此外,其他化合物被发现低于其定量限制。仅在干转移被动采样器的提取物中检测到10种分析物,突出了应用该方案的重要性,特别是在处理极性化合物时。因此,这种精细化的处理方法允许更标准化和可重复的策略,同时扩大了可检测和量化的分析物集。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Increasing chemical coverage, accuracy, and reproducibility of the processing method for polar organic chemical integrative samplers

Despite their diffusion in research studies, passive samplers are rarely used in regulatory applications. To expand the employment of passive samplers in regulatory environmental studies, standardized procedures for processing each sampler type should be proposed and accepted, but currently, each study develops its own protocol based on previous knowledge and specific needs. In this work, six identical polar organic chemical integrative samplers in seawater were deployed to understand the importance of the sorbent transfer method prior to the elution step. A common “wet transfer” with ultra-pure water was compared to a less diffused “dry-transfer,” assessing recoveries and matrix effects of 38 target compounds of emerging concern, including polar pesticides, recreational and food-related substances, pharmaceuticals, industrial additives, and ultra-violet (UV) filters. The dry-transfer procedure generally allowed better recoveries, especially for the more polar compounds, without affecting matrix effects (which remained in the range 40–130%). Along with the recovery assessment, the analysis of the non-spiked sorbent extracts revealed traces of many of the targeted emerging contaminants, quantifying perfluorooctanoic acid, UV-filters, carbamazepine, diclofenac, and triclosan. Furthermore, other compounds were found below their limits of quantitation. Ten analytes were detected only in the extracts of the dry-transferred passive samplers, highlighting the importance of applying this protocol, especially when dealing with polar compounds. This refined processing method, therefore, permits a more standardized and reproducible strategy, at the same time enlarging the set of analytes which could be detected and quantified.

Graphical abstract

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
8.00
自引率
4.70%
发文量
638
审稿时长
2.1 months
期刊介绍: Analytical and Bioanalytical Chemistry’s mission is the rapid publication of excellent and high-impact research articles on fundamental and applied topics of analytical and bioanalytical measurement science. Its scope is broad, and ranges from novel measurement platforms and their characterization to multidisciplinary approaches that effectively address important scientific problems. The Editors encourage submissions presenting innovative analytical research in concept, instrumentation, methods, and/or applications, including: mass spectrometry, spectroscopy, and electroanalysis; advanced separations; analytical strategies in “-omics” and imaging, bioanalysis, and sampling; miniaturized devices, medical diagnostics, sensors; analytical characterization of nano- and biomaterials; chemometrics and advanced data analysis.
期刊最新文献
Ultrasensitive electrochemiluminescence resonance energy transfer aptasensor for chloramphenicol detection integrated with a high-performance Tb-PTC/Ag MOF composite emitter. Machine learning-assisted SERS for rapid and accurate early screening of cervical cancer. A controllable glycosyl molecularly imprinted strategy on MOF nanozyme for high-specificity colorimetric detection of CA19-9. Chemometric electrochemical fingerprinting of thermal stress in honeybee larvae: a tool for discrimination and welfare assessment. Activatable fluorescent nanosensor for real-time detection and intracellular imaging of histone deacetylase 1.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1