19 ~ 87岁健康人脉络膜丛灌注成像单延时和多延时pCASL的重测研究

IF 5.3 2区 医学 Q1 NEUROIMAGING NeuroImage Pub Date : 2025-03-01 Epub Date: 2025-01-29 DOI:10.1016/j.neuroimage.2025.121048
Zixuan Liu , Qinyang Shou , Kay Jann , Chenyang Zhao , Danny JJ Wang , Xingfeng Shao
{"title":"19 ~ 87岁健康人脉络膜丛灌注成像单延时和多延时pCASL的重测研究","authors":"Zixuan Liu ,&nbsp;Qinyang Shou ,&nbsp;Kay Jann ,&nbsp;Chenyang Zhao ,&nbsp;Danny JJ Wang ,&nbsp;Xingfeng Shao","doi":"10.1016/j.neuroimage.2025.121048","DOIUrl":null,"url":null,"abstract":"<div><div>There is a growing interest in the choroid plexus (ChP) due to its critical role in cerebrospinal fluid (CSF) production and its involvement in neurodegenerative and cerebrovascular diseases. However, comprehensive studies comparing the accuracy and reliability of single- and multi-PLD (post-labeling delay) arterial spin labeling (ASL) techniques, specifically in relation to the ChP, remain limited. This study systematically evaluated the test-retest reliability and quantification accuracy of cerebral blood flow (CBF) measurements, focusing on the ChP, using single-delay and multi-delay 3D gradient-and-spin echo (GRASE) pseudo-continuous ASL (pCASL) on 28 subjects (aged 19 to 87 years, 14 males/14 females) at 3.0 tesla. Both single-delay (2 s) and 5-PLD (0.5 – 2.5 s) pCASL scans were repeated approximately one week apart with a spatial resolution of 2.5 × 2.5 × 3 mm³. Voxel-wise and regional CBF and arterial transit time (ATT) measurements were compared to assess test-retest reliability, with a particular focus on ChP perfusion changes with age. In this study, 12.15 % of ChP voxels exhibited ATTs longer than 2 s, potentially leading to a significant underestimation of CBF using single-delay ASL. Multi-delay ASL showed improved accuracy in estimating CBF values for the ChP compared to single-delay ASL when ATT &gt; PLD. Additionally, ChP volume (mean ± std = 1.72± 0.85 ml) increased (p &lt; 0.01) and ChP perfusion (43.07±14.18 mL/100 g/min) decreased (<em>p</em> = 0.04) with age. These findings underscore the robustness of multi-delay ASL with model-fitting quantification in assessing ChP perfusion, making it the preferred method for accurate CBF and ATT estimation, particularly in regions with prolonged transit time such as ChP.</div></div>","PeriodicalId":19299,"journal":{"name":"NeuroImage","volume":"308 ","pages":"Article 121048"},"PeriodicalIF":5.3000,"publicationDate":"2025-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Test-Retest Study of Single- and Multi-Delay pCASL for Choroid Plexus Perfusion Imaging in Healthy Subjects Aged 19 to 87 Years\",\"authors\":\"Zixuan Liu ,&nbsp;Qinyang Shou ,&nbsp;Kay Jann ,&nbsp;Chenyang Zhao ,&nbsp;Danny JJ Wang ,&nbsp;Xingfeng Shao\",\"doi\":\"10.1016/j.neuroimage.2025.121048\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>There is a growing interest in the choroid plexus (ChP) due to its critical role in cerebrospinal fluid (CSF) production and its involvement in neurodegenerative and cerebrovascular diseases. However, comprehensive studies comparing the accuracy and reliability of single- and multi-PLD (post-labeling delay) arterial spin labeling (ASL) techniques, specifically in relation to the ChP, remain limited. This study systematically evaluated the test-retest reliability and quantification accuracy of cerebral blood flow (CBF) measurements, focusing on the ChP, using single-delay and multi-delay 3D gradient-and-spin echo (GRASE) pseudo-continuous ASL (pCASL) on 28 subjects (aged 19 to 87 years, 14 males/14 females) at 3.0 tesla. Both single-delay (2 s) and 5-PLD (0.5 – 2.5 s) pCASL scans were repeated approximately one week apart with a spatial resolution of 2.5 × 2.5 × 3 mm³. Voxel-wise and regional CBF and arterial transit time (ATT) measurements were compared to assess test-retest reliability, with a particular focus on ChP perfusion changes with age. In this study, 12.15 % of ChP voxels exhibited ATTs longer than 2 s, potentially leading to a significant underestimation of CBF using single-delay ASL. Multi-delay ASL showed improved accuracy in estimating CBF values for the ChP compared to single-delay ASL when ATT &gt; PLD. Additionally, ChP volume (mean ± std = 1.72± 0.85 ml) increased (p &lt; 0.01) and ChP perfusion (43.07±14.18 mL/100 g/min) decreased (<em>p</em> = 0.04) with age. These findings underscore the robustness of multi-delay ASL with model-fitting quantification in assessing ChP perfusion, making it the preferred method for accurate CBF and ATT estimation, particularly in regions with prolonged transit time such as ChP.</div></div>\",\"PeriodicalId\":19299,\"journal\":{\"name\":\"NeuroImage\",\"volume\":\"308 \",\"pages\":\"Article 121048\"},\"PeriodicalIF\":5.3000,\"publicationDate\":\"2025-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"NeuroImage\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1053811925000503\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/1/29 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"NEUROIMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"NeuroImage","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1053811925000503","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/29 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"NEUROIMAGING","Score":null,"Total":0}
引用次数: 0

摘要

由于脉络膜丛(ChP)在脑脊液(CSF)的产生中起关键作用,并参与神经退行性和脑血管疾病,人们对其越来越感兴趣。然而,比较单和多pld(标记后延迟)动脉自旋标记(ASL)技术的准确性和可靠性的综合研究,特别是与ChP相关的研究仍然有限。本研究采用单延迟和多延迟3D梯度-自旋回波(GRASE)伪连续ASL (pCASL)对28名年龄在19 ~ 87岁,男14 /女14名的被试在3.0特斯拉下进行脑血流(CBF)测量,以ChP为重点,系统评估了重测信度和定量准确性。单延迟(2秒)和5-PLD(0.5 - 2.5秒)pCASL扫描间隔约一周重复,空间分辨率为2.5×2.5×3 mm³。比较体素和区域CBF和动脉传递时间(ATT)测量值,以评估重测可靠性,特别关注ChP灌注随年龄的变化。在这项研究中,12.15%的ChP体素表现出超过2秒的at,这可能导致单延迟ASL对CBF的严重低估。与单延迟ASL相比,多延迟ASL在估计ChP的CBF值时显示出更高的准确性。ChP体积(平均±std = 1.72±0.85 ml)增加(p
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A Test-Retest Study of Single- and Multi-Delay pCASL for Choroid Plexus Perfusion Imaging in Healthy Subjects Aged 19 to 87 Years
There is a growing interest in the choroid plexus (ChP) due to its critical role in cerebrospinal fluid (CSF) production and its involvement in neurodegenerative and cerebrovascular diseases. However, comprehensive studies comparing the accuracy and reliability of single- and multi-PLD (post-labeling delay) arterial spin labeling (ASL) techniques, specifically in relation to the ChP, remain limited. This study systematically evaluated the test-retest reliability and quantification accuracy of cerebral blood flow (CBF) measurements, focusing on the ChP, using single-delay and multi-delay 3D gradient-and-spin echo (GRASE) pseudo-continuous ASL (pCASL) on 28 subjects (aged 19 to 87 years, 14 males/14 females) at 3.0 tesla. Both single-delay (2 s) and 5-PLD (0.5 – 2.5 s) pCASL scans were repeated approximately one week apart with a spatial resolution of 2.5 × 2.5 × 3 mm³. Voxel-wise and regional CBF and arterial transit time (ATT) measurements were compared to assess test-retest reliability, with a particular focus on ChP perfusion changes with age. In this study, 12.15 % of ChP voxels exhibited ATTs longer than 2 s, potentially leading to a significant underestimation of CBF using single-delay ASL. Multi-delay ASL showed improved accuracy in estimating CBF values for the ChP compared to single-delay ASL when ATT > PLD. Additionally, ChP volume (mean ± std = 1.72± 0.85 ml) increased (p < 0.01) and ChP perfusion (43.07±14.18 mL/100 g/min) decreased (p = 0.04) with age. These findings underscore the robustness of multi-delay ASL with model-fitting quantification in assessing ChP perfusion, making it the preferred method for accurate CBF and ATT estimation, particularly in regions with prolonged transit time such as ChP.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
NeuroImage
NeuroImage 医学-核医学
CiteScore
11.30
自引率
10.50%
发文量
809
审稿时长
63 days
期刊介绍: NeuroImage, a Journal of Brain Function provides a vehicle for communicating important advances in acquiring, analyzing, and modelling neuroimaging data and in applying these techniques to the study of structure-function and brain-behavior relationships. Though the emphasis is on the macroscopic level of human brain organization, meso-and microscopic neuroimaging across all species will be considered if informative for understanding the aforementioned relationships.
期刊最新文献
A two-level hierarchy underlies auditory novelty processing in the human brain Cerebral glucose utilisation during musical emotions: A multimodal functional PET/MRI study EEG functional connectivity methods for seizure-related disorders Divergent neural mechanisms of memory updating under varying degrees of inconsistency Membrane and bioenergetic dysfunction in Parkinson's disease with REM sleep behavior disorder: A 31P and 1H MR study
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1