晶状体偏心和倾斜对植入双焦点或扩展聚焦深度人工晶状体后视力的影响。

IF 2.1 4区 医学 Q3 OPHTHALMOLOGY BMC Ophthalmology Pub Date : 2025-02-03 DOI:10.1186/s12886-025-03884-5
Yu Zhang, Jiaqing Zhang, Chen Liang, Yifan Xu, Jiaying Wu, Junming Wu, Yifan Zhang, Aixia Jin, Xuhua Tan, Lixia Luo
{"title":"晶状体偏心和倾斜对植入双焦点或扩展聚焦深度人工晶状体后视力的影响。","authors":"Yu Zhang, Jiaqing Zhang, Chen Liang, Yifan Xu, Jiaying Wu, Junming Wu, Yifan Zhang, Aixia Jin, Xuhua Tan, Lixia Luo","doi":"10.1186/s12886-025-03884-5","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To explore the potential of crystalline lens decentration and tilt as indicators for screening cataract patients for presbyopia-correcting intraocular lens (IOL) implantation.</p><p><strong>Methods: </strong>Prospective observational study. Patients undergoing phacoemulsification with bifocal (Tecnis ZMB00) or extended depth-of-focus (EDOF) (Tecnis ZXR00) IOL implantation were consecutively enrolled. The decentration and tilt of the crystalline lens and the IOL were quantified through the utilization of swept-source optical coherence tomography (SS-OCT, Casia2). Postoperative visual acuity (VA), contrast sensitivity (CS), objective optical quality, and patient-reported outcomes were assessed at a 3-month follow-up. A LOWESS (LOcally WEighted Scatterplot Smoothing) curve was employed to analyze the changes in VA, CS, and objective optical quality relative to the decentration or tilt of crystalline lenses. A further comparison of visual outcomes was conducted based on the inflection points suggested by the curves.</p><p><strong>Results: </strong>Eighty‑seven patients with ZMB00 IOL and 76 patients with ZXR00 IOL were included. Multiple 6-mm internal aberrations showed a nonlinear increase with greater crystalline lens decentration. The inflection points for the steep increase were observed to be 0.28 mm for the bifocal group and 0.35 mm for the EDOF group. Beyond these points, internal aberrations such as coma increased significantly (all P < 0.01). Patient satisfaction decreased (P < 0.01). Moreover, the bifocal group exhibited a decline in spectacle-independence from 98.67% to 83.33% (P = 0.049), along with a reduction in CS (P < 0.05).</p><p><strong>Conclusions: </strong>The increased decentration of crystalline lenses compromises specific visual quality aspects in eyes implanted with ZMB00 and ZXR00 IOLs, with cut-off values of 0.28 mm and 0.35 mm, respectively.</p>","PeriodicalId":9058,"journal":{"name":"BMC Ophthalmology","volume":"25 1","pages":"58"},"PeriodicalIF":2.1000,"publicationDate":"2025-02-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11792569/pdf/","citationCount":"0","resultStr":"{\"title\":\"Effect of crystalline lens decentration and tilt on visual performance in eyes implanted with bifocal or extended depth of focus intraocular lenses.\",\"authors\":\"Yu Zhang, Jiaqing Zhang, Chen Liang, Yifan Xu, Jiaying Wu, Junming Wu, Yifan Zhang, Aixia Jin, Xuhua Tan, Lixia Luo\",\"doi\":\"10.1186/s12886-025-03884-5\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To explore the potential of crystalline lens decentration and tilt as indicators for screening cataract patients for presbyopia-correcting intraocular lens (IOL) implantation.</p><p><strong>Methods: </strong>Prospective observational study. Patients undergoing phacoemulsification with bifocal (Tecnis ZMB00) or extended depth-of-focus (EDOF) (Tecnis ZXR00) IOL implantation were consecutively enrolled. The decentration and tilt of the crystalline lens and the IOL were quantified through the utilization of swept-source optical coherence tomography (SS-OCT, Casia2). Postoperative visual acuity (VA), contrast sensitivity (CS), objective optical quality, and patient-reported outcomes were assessed at a 3-month follow-up. A LOWESS (LOcally WEighted Scatterplot Smoothing) curve was employed to analyze the changes in VA, CS, and objective optical quality relative to the decentration or tilt of crystalline lenses. A further comparison of visual outcomes was conducted based on the inflection points suggested by the curves.</p><p><strong>Results: </strong>Eighty‑seven patients with ZMB00 IOL and 76 patients with ZXR00 IOL were included. Multiple 6-mm internal aberrations showed a nonlinear increase with greater crystalline lens decentration. The inflection points for the steep increase were observed to be 0.28 mm for the bifocal group and 0.35 mm for the EDOF group. Beyond these points, internal aberrations such as coma increased significantly (all P < 0.01). Patient satisfaction decreased (P < 0.01). Moreover, the bifocal group exhibited a decline in spectacle-independence from 98.67% to 83.33% (P = 0.049), along with a reduction in CS (P < 0.05).</p><p><strong>Conclusions: </strong>The increased decentration of crystalline lenses compromises specific visual quality aspects in eyes implanted with ZMB00 and ZXR00 IOLs, with cut-off values of 0.28 mm and 0.35 mm, respectively.</p>\",\"PeriodicalId\":9058,\"journal\":{\"name\":\"BMC Ophthalmology\",\"volume\":\"25 1\",\"pages\":\"58\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2025-02-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11792569/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"BMC Ophthalmology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s12886-025-03884-5\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12886-025-03884-5","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:探讨晶状体离体和晶状体倾斜作为筛选白内障患者进行矫正老花人工晶状体植入术的指标的潜力。方法:前瞻性观察研究。连续入组行双焦点(Tecnis ZMB00)或扩大聚焦深度(EDOF) (Tecnis ZXR00)人工晶体植入术的患者。利用扫源光学相干层析成像(SS-OCT, Casia2)对晶状体和人工晶体的偏心和倾斜进行量化。术后视力(VA)、对比敏感度(CS)、客观光学质量和患者报告的结果在3个月的随访中进行评估。采用LOWESS(局部加权散点图平滑)曲线分析VA、CS和物镜光学质量相对于晶体透镜偏心或倾斜的变化。根据曲线提示的拐点进一步比较视觉结果。结果:纳入ZMB00型人工晶状体87例,ZXR00型人工晶状体76例。多个6 mm内像差随晶状体偏心增大呈非线性增加。观察到双焦点组的急剧增加的拐点为0.28 mm, EDOF组为0.35 mm。结论:植入ZMB00和ZXR00人工晶状体后,晶状体离体的增加会影响眼睛特定的视觉质量,其截止值分别为0.28 mm和0.35 mm。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Effect of crystalline lens decentration and tilt on visual performance in eyes implanted with bifocal or extended depth of focus intraocular lenses.

Purpose: To explore the potential of crystalline lens decentration and tilt as indicators for screening cataract patients for presbyopia-correcting intraocular lens (IOL) implantation.

Methods: Prospective observational study. Patients undergoing phacoemulsification with bifocal (Tecnis ZMB00) or extended depth-of-focus (EDOF) (Tecnis ZXR00) IOL implantation were consecutively enrolled. The decentration and tilt of the crystalline lens and the IOL were quantified through the utilization of swept-source optical coherence tomography (SS-OCT, Casia2). Postoperative visual acuity (VA), contrast sensitivity (CS), objective optical quality, and patient-reported outcomes were assessed at a 3-month follow-up. A LOWESS (LOcally WEighted Scatterplot Smoothing) curve was employed to analyze the changes in VA, CS, and objective optical quality relative to the decentration or tilt of crystalline lenses. A further comparison of visual outcomes was conducted based on the inflection points suggested by the curves.

Results: Eighty‑seven patients with ZMB00 IOL and 76 patients with ZXR00 IOL were included. Multiple 6-mm internal aberrations showed a nonlinear increase with greater crystalline lens decentration. The inflection points for the steep increase were observed to be 0.28 mm for the bifocal group and 0.35 mm for the EDOF group. Beyond these points, internal aberrations such as coma increased significantly (all P < 0.01). Patient satisfaction decreased (P < 0.01). Moreover, the bifocal group exhibited a decline in spectacle-independence from 98.67% to 83.33% (P = 0.049), along with a reduction in CS (P < 0.05).

Conclusions: The increased decentration of crystalline lenses compromises specific visual quality aspects in eyes implanted with ZMB00 and ZXR00 IOLs, with cut-off values of 0.28 mm and 0.35 mm, respectively.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
BMC Ophthalmology
BMC Ophthalmology OPHTHALMOLOGY-
CiteScore
3.40
自引率
5.00%
发文量
441
审稿时长
6-12 weeks
期刊介绍: BMC Ophthalmology is an open access, peer-reviewed journal that considers articles on all aspects of the prevention, diagnosis and management of eye disorders, as well as related molecular genetics, pathophysiology, and epidemiology.
期刊最新文献
Effect of topical phenylephrine on aqueous flare levels and anterior scleral thickness in healthy adult eyes. Early detection of tamoxifen-induced retinal injury: ellipsoid zone reflectivity as a sensitive structural marker. Experimental knotless scleral fixation with expanded polytetrafluoroethylene (ePTFE): dynamics of anchoring strength in the early postoperative period. Rhythmic suture movement on gonioscopy after penetrating canaloplasty: a case report. The role of DNMT3B, GSK-3β and GJA3 in lens epithelial cell apoptosis and age-related cataract.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1