Giorgio Gianini Morbioli, Keith R. Baillargeon, Monalisa N. Kalimashe, Vibha Kana, Hloniphile Zwane, Cheri van der Walt, Allison J. Tierney, Andrea C. Mora, Mark Goosen, Rivashni Jagaroo, Jessica C. Brooks, Ewaldé Cutler, Gillian Hunt, Michael R. Jordan, Alice Tang, Charles R. Mace
{"title":"Clinical evaluation of patterned dried plasma spot cards to support quantification of HIV viral load and reflexive genotyping","authors":"Giorgio Gianini Morbioli, Keith R. Baillargeon, Monalisa N. Kalimashe, Vibha Kana, Hloniphile Zwane, Cheri van der Walt, Allison J. Tierney, Andrea C. Mora, Mark Goosen, Rivashni Jagaroo, Jessica C. Brooks, Ewaldé Cutler, Gillian Hunt, Michael R. Jordan, Alice Tang, Charles R. Mace","doi":"10.1073/pnas.2419160122","DOIUrl":null,"url":null,"abstract":"Quantifying viral load, a key indicator required to achieve control and elimination of the HIV epidemic, requires cell-free plasma or serum to ensure measurements are not biased by proviral DNA contained in infected CD4 T lymphocytes. Plasma separation cards (PSC) collect and preserve a dried specimen, which makes them practical solutions for decentralized sample collection and transport in limited-resource settings. However, physiological variations in hematocrit levels can introduce significant variability in the quality of plasma generated by commercial PSCs and can lead to inaccurate test results and clinical decisions. In addition to hematocrit-dependent sampling, the Roche PSC, a standard for dried plasma collection, is known to induce considerable hemolysis, which further impacts specimen quality, concordance with liquid plasma, and the overall benefit of microsampling. We address these gaps with a patterned dried plasma spot (pDPS) card, which generates plasma with improved hematocrit independence and minimal hemolysis. This study directly compares pDPS cards to the Roche PSC to measure HIV viral load. Analysis of viral load from 75 donors revealed strong agreement in sensitivity, specificity, overall accuracy, and viral load band placement between devices, with quantitative metrics suggesting improved performance for pDPS cards. In reflexive genotyping, remnant dried blood from pDPS cards exhibited greater success than Roche PSC in amplification and sequencing (71% vs. 62%) and detecting drug resistance mutations (63% vs. 42%). Based on this performance, pDPS cards can be versatile across multiple analytical platforms, integrate seamlessly into existing clinical laboratory workflows, and aid clinicians in making accurate treatment decisions.","PeriodicalId":20548,"journal":{"name":"Proceedings of the National Academy of Sciences of the United States of America","volume":"48 1","pages":""},"PeriodicalIF":9.4000,"publicationDate":"2025-02-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the National Academy of Sciences of the United States of America","FirstCategoryId":"103","ListUrlMain":"https://doi.org/10.1073/pnas.2419160122","RegionNum":1,"RegionCategory":"综合性期刊","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MULTIDISCIPLINARY SCIENCES","Score":null,"Total":0}
引用次数: 0
摘要
病毒载量是控制和消除艾滋病疫情的一项关键指标,对其进行量化需要无细胞血浆或血清,以确保测量结果不会受到受感染的 CD4 T 淋巴细胞中所含的前病毒 DNA 的影响。血浆分离卡(PSC)可收集并保存干燥的样本,这使其成为在资源有限的环境中进行分散样本收集和运输的实用解决方案。然而,血细胞比容水平的生理变化会对商用血浆分离卡产生的血浆质量造成很大的影响,从而导致检测结果和临床决策的不准确。除了依赖血细胞比容采样外,众所周知,罗氏 PSC(干血浆采集的标准)会引起大量溶血,这进一步影响了标本质量、与液体血浆的一致性以及微采样的整体效益。我们采用图案化干血浆点(pDPS)卡弥补了这些不足,该卡生成的血浆具有更好的血细胞比容独立性,溶血现象极少。本研究将 pDPS 卡与罗氏 PSC 进行了直接比较,以测量 HIV 病毒载量。对 75 名捐献者的病毒载量进行分析后发现,两种设备在灵敏度、特异性、总体准确性和病毒载量带位置上都非常一致,定量指标表明 pDPS 卡的性能有所提高。在反射性基因分型中,pDPS 卡的残留干血在扩增和测序(71% 对 62%)以及检测耐药性突变(63% 对 42%)方面的成功率高于罗氏 PSC。基于这种性能,pDPS 卡可以在多个分析平台上通用,无缝集成到现有的临床实验室工作流程中,帮助临床医生做出准确的治疗决策。
Clinical evaluation of patterned dried plasma spot cards to support quantification of HIV viral load and reflexive genotyping
Quantifying viral load, a key indicator required to achieve control and elimination of the HIV epidemic, requires cell-free plasma or serum to ensure measurements are not biased by proviral DNA contained in infected CD4 T lymphocytes. Plasma separation cards (PSC) collect and preserve a dried specimen, which makes them practical solutions for decentralized sample collection and transport in limited-resource settings. However, physiological variations in hematocrit levels can introduce significant variability in the quality of plasma generated by commercial PSCs and can lead to inaccurate test results and clinical decisions. In addition to hematocrit-dependent sampling, the Roche PSC, a standard for dried plasma collection, is known to induce considerable hemolysis, which further impacts specimen quality, concordance with liquid plasma, and the overall benefit of microsampling. We address these gaps with a patterned dried plasma spot (pDPS) card, which generates plasma with improved hematocrit independence and minimal hemolysis. This study directly compares pDPS cards to the Roche PSC to measure HIV viral load. Analysis of viral load from 75 donors revealed strong agreement in sensitivity, specificity, overall accuracy, and viral load band placement between devices, with quantitative metrics suggesting improved performance for pDPS cards. In reflexive genotyping, remnant dried blood from pDPS cards exhibited greater success than Roche PSC in amplification and sequencing (71% vs. 62%) and detecting drug resistance mutations (63% vs. 42%). Based on this performance, pDPS cards can be versatile across multiple analytical platforms, integrate seamlessly into existing clinical laboratory workflows, and aid clinicians in making accurate treatment decisions.
期刊介绍:
The Proceedings of the National Academy of Sciences (PNAS), a peer-reviewed journal of the National Academy of Sciences (NAS), serves as an authoritative source for high-impact, original research across the biological, physical, and social sciences. With a global scope, the journal welcomes submissions from researchers worldwide, making it an inclusive platform for advancing scientific knowledge.