IF 3.6 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry Pub Date : 2026-03-16 Epub Date: 2025-02-10 DOI:10.1111/jopr.14042
Nada A. Abdelhakim BDS, Rodrigo Salazar-Gamarra DDS, MS, PhD, Lucette G. Segaan BDS, MSc, PhD, Ingy S. Soliman BDS, MSc, PhD
{"title":"三维面部扫描口腔外表面数据采集的不同技术评价。","authors":"Nada A. Abdelhakim BDS,&nbsp;Rodrigo Salazar-Gamarra DDS, MS, PhD,&nbsp;Lucette G. Segaan BDS, MSc, PhD,&nbsp;Ingy S. Soliman BDS, MSc, PhD","doi":"10.1111/jopr.14042","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Purpose</h3>\n \n <p>This study evaluated the accuracy (trueness and precision) of facial scanners using different technologies and the reliability of the texture maps produced.</p>\n </section>\n \n <section>\n \n <h3> Materials and Methods</h3>\n \n <p>A volunteer was scanned using nine scanners: Cloner, Artec MHT, Revopoint Mini, Revopoint POP 2, Vectra H2, EXAscan, Scaniverse app, iPhone 13 Pro MAX, and Nikon Z 7II Camera. Eighty scans were compared to a reference model (Vectra XT). Root mean square and standard deviation of the dimensional discrepancies were analyzed using ANOVA and Tukey post-hoc test. Acquisition times were assessed using Kruskal–Wallis test followed by Mann–Whitney <i>U</i>-test. Two expert assessments on texture map realism were averaged and compared to the reference using one sample <i>t</i>-test. The two experts' intraclass correlation coefficient (ICC) was calculated.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>Eight scanners fully captured the three-dimensional facial geometry. Overall trueness and precision of the facial scanners were significantly different (<i>p</i> &lt; 0.001). Seven scanners showed clinically acceptable scanning accuracy of less than or equal to 2 mm. Cloner displayed the lowest deviation (0.61 ± 0.08 mm), fastest acquisition time (0.40 ± 0.00 s), and was highly reliable (&lt;1 mm). The texture map of the Vectra H2 had the highest mean score of 8.50 and was the most realistic. The ICC between the experts was 0.78 indicating good interexaminer reliability.</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>The more economical facial scanners within each scanning technology (iPhone 13 Pro MAX, Cloner, Revopoint MINI, and Scaniverse app) showed clinically acceptable accuracy with realistic texture maps for facial scanning and therefore could be eligible substitutes for professional higher-cost scanners.</p>\n </section>\n </div>","PeriodicalId":49152,"journal":{"name":"Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry","volume":"35 3","pages":"297-306"},"PeriodicalIF":3.6000,"publicationDate":"2026-03-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of different technologies used for extraoral surface data acquisition for 3D facial scanning\",\"authors\":\"Nada A. Abdelhakim BDS,&nbsp;Rodrigo Salazar-Gamarra DDS, MS, PhD,&nbsp;Lucette G. Segaan BDS, MSc, PhD,&nbsp;Ingy S. Soliman BDS, MSc, PhD\",\"doi\":\"10.1111/jopr.14042\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n \\n <section>\\n \\n <h3> Purpose</h3>\\n \\n <p>This study evaluated the accuracy (trueness and precision) of facial scanners using different technologies and the reliability of the texture maps produced.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Materials and Methods</h3>\\n \\n <p>A volunteer was scanned using nine scanners: Cloner, Artec MHT, Revopoint Mini, Revopoint POP 2, Vectra H2, EXAscan, Scaniverse app, iPhone 13 Pro MAX, and Nikon Z 7II Camera. Eighty scans were compared to a reference model (Vectra XT). Root mean square and standard deviation of the dimensional discrepancies were analyzed using ANOVA and Tukey post-hoc test. Acquisition times were assessed using Kruskal–Wallis test followed by Mann–Whitney <i>U</i>-test. Two expert assessments on texture map realism were averaged and compared to the reference using one sample <i>t</i>-test. The two experts' intraclass correlation coefficient (ICC) was calculated.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Results</h3>\\n \\n <p>Eight scanners fully captured the three-dimensional facial geometry. Overall trueness and precision of the facial scanners were significantly different (<i>p</i> &lt; 0.001). Seven scanners showed clinically acceptable scanning accuracy of less than or equal to 2 mm. Cloner displayed the lowest deviation (0.61 ± 0.08 mm), fastest acquisition time (0.40 ± 0.00 s), and was highly reliable (&lt;1 mm). The texture map of the Vectra H2 had the highest mean score of 8.50 and was the most realistic. The ICC between the experts was 0.78 indicating good interexaminer reliability.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Conclusions</h3>\\n \\n <p>The more economical facial scanners within each scanning technology (iPhone 13 Pro MAX, Cloner, Revopoint MINI, and Scaniverse app) showed clinically acceptable accuracy with realistic texture maps for facial scanning and therefore could be eligible substitutes for professional higher-cost scanners.</p>\\n </section>\\n </div>\",\"PeriodicalId\":49152,\"journal\":{\"name\":\"Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry\",\"volume\":\"35 3\",\"pages\":\"297-306\"},\"PeriodicalIF\":3.6000,\"publicationDate\":\"2026-03-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1111/jopr.14042\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/2/10 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/jopr.14042","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/2/10 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究评估使用不同技术的面部扫描仪的准确性(真实度和精密度)以及所产生的纹理图的可靠性。材料和方法:使用9台扫描仪对志愿者进行扫描:Cloner、Artec MHT、revpoint Mini、revpoint POP 2、Vectra H2、EXAscan、Scaniverse app、iPhone 13 Pro MAX和Nikon Z 7II相机。80次扫描与参考模型(Vectra XT)进行比较。采用方差分析和Tukey事后检验分析各维度差异的均方根和标准差。习得时间采用Kruskal-Wallis检验和Mann-Whitney u检验。对纹理贴图真实感的两个专家评估取平均值,并使用一个样本t检验与参考进行比较。计算两位专家的类内相关系数(ICC)。结果:8台扫描仪完全捕获了三维面部几何形状。面部扫描仪的整体准确性和准确性有显著性差异(p < 0.001)。7台扫描仪显示临床可接受的扫描精度小于或等于2mm。Cloner显示最小的偏差(0.61±0.08 mm),最快的采集时间(0.40±0.00 s),并且具有很高的可靠性(结论:每种扫描技术中更经济的面部扫描仪(iPhone 13 Pro MAX, Cloner, revpoint MINI和Scaniverse app)具有临床可接受的准确性,具有逼真的面部扫描纹理图,因此可以替代专业的高成本扫描仪。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Evaluation of different technologies used for extraoral surface data acquisition for 3D facial scanning

Purpose

This study evaluated the accuracy (trueness and precision) of facial scanners using different technologies and the reliability of the texture maps produced.

Materials and Methods

A volunteer was scanned using nine scanners: Cloner, Artec MHT, Revopoint Mini, Revopoint POP 2, Vectra H2, EXAscan, Scaniverse app, iPhone 13 Pro MAX, and Nikon Z 7II Camera. Eighty scans were compared to a reference model (Vectra XT). Root mean square and standard deviation of the dimensional discrepancies were analyzed using ANOVA and Tukey post-hoc test. Acquisition times were assessed using Kruskal–Wallis test followed by Mann–Whitney U-test. Two expert assessments on texture map realism were averaged and compared to the reference using one sample t-test. The two experts' intraclass correlation coefficient (ICC) was calculated.

Results

Eight scanners fully captured the three-dimensional facial geometry. Overall trueness and precision of the facial scanners were significantly different (p < 0.001). Seven scanners showed clinically acceptable scanning accuracy of less than or equal to 2 mm. Cloner displayed the lowest deviation (0.61 ± 0.08 mm), fastest acquisition time (0.40 ± 0.00 s), and was highly reliable (<1 mm). The texture map of the Vectra H2 had the highest mean score of 8.50 and was the most realistic. The ICC between the experts was 0.78 indicating good interexaminer reliability.

Conclusions

The more economical facial scanners within each scanning technology (iPhone 13 Pro MAX, Cloner, Revopoint MINI, and Scaniverse app) showed clinically acceptable accuracy with realistic texture maps for facial scanning and therefore could be eligible substitutes for professional higher-cost scanners.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
7.90
自引率
15.00%
发文量
171
审稿时长
6-12 weeks
期刊介绍: The Journal of Prosthodontics promotes the advanced study and practice of prosthodontics, implant, esthetic, and reconstructive dentistry. It is the official journal of the American College of Prosthodontists, the American Dental Association-recognized voice of the Specialty of Prosthodontics. The journal publishes evidence-based original scientific articles presenting information that is relevant and useful to prosthodontists. Additionally, it publishes reports of innovative techniques, new instructional methodologies, and instructive clinical reports with an interdisciplinary flair. The journal is particularly focused on promoting the study and use of cutting-edge technology and positioning prosthodontists as the early-adopters of new technology in the dental community.
期刊最新文献
Improving the cytocompatibility and functionality of titanium implants by adjusting the electrolyte of the anodization method. Evaluation of microhardness, degree of conversion, and abrasion resistance of nanoglass and multiwalled carbon nanotubes reinforced three-dimensionally printed denture base resins Effect of different surface treatments and adhesive cementation on the surface topography and flexural strength of translucent and ultra-translucent monolithic zirconia Investigating the impact of different cleaning techniques on bond strength between resin cement and zirconia and the resulting physical and chemical surface alterations Repair strength of 3D-printed denture base resins: Effect of surface treatment and repair material type
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1