公共场所小卖部的血压测量:国际高血压学会和世界高血压联盟认可的欧洲高血压学会血压监测和心血管变异性工作组的系统评价和共识声明。

IF 4.1 2区 医学 Q1 PERIPHERAL VASCULAR DISEASE Journal of Hypertension Pub Date : 2025-04-01 Epub Date: 2025-01-13 DOI:10.1097/HJH.0000000000003965
George S Stergiou, Konstantinos G Kyriakoulis, Anastasios Kollias, Richard J McManus, Ariadni Menti, Gianfranco Parati, Aletta E Schutte, Jiguang Wang, Kei Asayama, Roland Asmar, Grzegorz Bilo, Niamh Chapman, Takeshi Fujiwara, Geoffrey Head, Nadia Kahn, Kazuomi Kario, Yan Li, Efstathios Manios, Dimitrios Mariglis, Anastasia S Mihailidou, Paul Muntner, Martin Myers, Teemu Niiranen, Takayoshi Ohkubo, Stefano Omboni, Athanasios Protogerou, Francesca Saladini, James Sharman, Daichi Shimbo, Alejandro De La Sierra, Paolo Palatini
{"title":"公共场所小卖部的血压测量:国际高血压学会和世界高血压联盟认可的欧洲高血压学会血压监测和心血管变异性工作组的系统评价和共识声明。","authors":"George S Stergiou, Konstantinos G Kyriakoulis, Anastasios Kollias, Richard J McManus, Ariadni Menti, Gianfranco Parati, Aletta E Schutte, Jiguang Wang, Kei Asayama, Roland Asmar, Grzegorz Bilo, Niamh Chapman, Takeshi Fujiwara, Geoffrey Head, Nadia Kahn, Kazuomi Kario, Yan Li, Efstathios Manios, Dimitrios Mariglis, Anastasia S Mihailidou, Paul Muntner, Martin Myers, Teemu Niiranen, Takayoshi Ohkubo, Stefano Omboni, Athanasios Protogerou, Francesca Saladini, James Sharman, Daichi Shimbo, Alejandro De La Sierra, Paolo Palatini","doi":"10.1097/HJH.0000000000003965","DOIUrl":null,"url":null,"abstract":"<p><p>Kiosk devices for unsupervised self-measurement of blood pressure (BP) are being used in public spaces and healthcare settings in several countries. This statement by the European Society of Hypertension (ESH) Working Group on BP Monitoring and Cardiovascular Variability provides a review of the published evidence on kiosk BP devices and consensus recommendations for their requirements and clinical use. A systematic literature search identified 54 relevant studies. Kiosk BP measurements appeared to be close to office BP [mean difference systolic 0.2 mmHg (95% confidence intervals -1.3 to 1.8); diastolic -0.4 mmHg (-3.5 to 2.7)], and higher than daytime ambulatory and home BP [mean difference 6.0 mmHg (1.6-10.4)/5.0 (2-8) and 8.1 mmHg (-2.6 to 18.9)/0.2 (-9.6 to 10.0), respectively]. Randomized or observational studies using kiosk BP measurements for hypertension screening or for assessing hypertension control were also included, as well as studies investigating users' and healthcare professionals' opinions, acceptability, and perspectives regarding kiosk BP measurements, and validation studies of kiosk BP devices. These studies had considerable heterogeneity in design, setting, methodology, measurement protocol, and sample size. Thus, at present, the clinical utility of kiosk BP measurements is uncertain. This ESH consensus statement acknowledges the potential of kiosk BP measurement as an emerging method for unsupervised self-measurement in the context of opportunistic screening for hypertension in apparently healthy people and the long-term monitoring of people with diagnosed hypertension. Requirements for the design, validation, function, and use of kiosk BP monitors are provided, together with the pending research questions on their optimal implementation in clinical practice.</p>","PeriodicalId":16043,"journal":{"name":"Journal of Hypertension","volume":" ","pages":"577-588"},"PeriodicalIF":4.1000,"publicationDate":"2025-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Blood pressure measurement at kiosks in public spaces: systematic review and consensus statement by the European Society of Hypertension Working Group on Blood Pressure Monitoring and Cardiovascular Variability endorsed by the International Society of Hypertension and the World Hypertension League.\",\"authors\":\"George S Stergiou, Konstantinos G Kyriakoulis, Anastasios Kollias, Richard J McManus, Ariadni Menti, Gianfranco Parati, Aletta E Schutte, Jiguang Wang, Kei Asayama, Roland Asmar, Grzegorz Bilo, Niamh Chapman, Takeshi Fujiwara, Geoffrey Head, Nadia Kahn, Kazuomi Kario, Yan Li, Efstathios Manios, Dimitrios Mariglis, Anastasia S Mihailidou, Paul Muntner, Martin Myers, Teemu Niiranen, Takayoshi Ohkubo, Stefano Omboni, Athanasios Protogerou, Francesca Saladini, James Sharman, Daichi Shimbo, Alejandro De La Sierra, Paolo Palatini\",\"doi\":\"10.1097/HJH.0000000000003965\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Kiosk devices for unsupervised self-measurement of blood pressure (BP) are being used in public spaces and healthcare settings in several countries. This statement by the European Society of Hypertension (ESH) Working Group on BP Monitoring and Cardiovascular Variability provides a review of the published evidence on kiosk BP devices and consensus recommendations for their requirements and clinical use. A systematic literature search identified 54 relevant studies. Kiosk BP measurements appeared to be close to office BP [mean difference systolic 0.2 mmHg (95% confidence intervals -1.3 to 1.8); diastolic -0.4 mmHg (-3.5 to 2.7)], and higher than daytime ambulatory and home BP [mean difference 6.0 mmHg (1.6-10.4)/5.0 (2-8) and 8.1 mmHg (-2.6 to 18.9)/0.2 (-9.6 to 10.0), respectively]. Randomized or observational studies using kiosk BP measurements for hypertension screening or for assessing hypertension control were also included, as well as studies investigating users' and healthcare professionals' opinions, acceptability, and perspectives regarding kiosk BP measurements, and validation studies of kiosk BP devices. These studies had considerable heterogeneity in design, setting, methodology, measurement protocol, and sample size. Thus, at present, the clinical utility of kiosk BP measurements is uncertain. This ESH consensus statement acknowledges the potential of kiosk BP measurement as an emerging method for unsupervised self-measurement in the context of opportunistic screening for hypertension in apparently healthy people and the long-term monitoring of people with diagnosed hypertension. Requirements for the design, validation, function, and use of kiosk BP monitors are provided, together with the pending research questions on their optimal implementation in clinical practice.</p>\",\"PeriodicalId\":16043,\"journal\":{\"name\":\"Journal of Hypertension\",\"volume\":\" \",\"pages\":\"577-588\"},\"PeriodicalIF\":4.1000,\"publicationDate\":\"2025-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Hypertension\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/HJH.0000000000003965\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/1/13 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"PERIPHERAL VASCULAR DISEASE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Hypertension","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/HJH.0000000000003965","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/13 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
引用次数: 0

摘要

在一些国家,用于无监督自我测量血压(BP)的Kiosk设备正在公共场所和医疗机构中使用。这份由欧洲高血压学会(ESH)血压监测和心血管变异性工作组发表的声明提供了关于kiosk血压装置的已发表证据的回顾,以及对其要求和临床使用的共识建议。系统文献检索确定了54项相关研究。Kiosk血压测量值似乎接近办公室血压[收缩压平均差0.2 mmHg(95%置信区间-1.3至1.8);舒张血压-0.4 mmHg(-3.5 ~ 2.7)],高于日间动态血压和居家血压[平均差值分别为6.0 mmHg(1.6 ~ 10.4)/5.0(2 ~ 8)和8.1 mmHg(-2.6 ~ 18.9)/0.2(-9.6 ~ 10.0)]。还包括使用kiosk血压测量进行高血压筛查或评估高血压控制的随机或观察性研究,以及调查用户和医疗保健专业人员对kiosk血压测量的意见、可接受性和观点的研究,以及kiosk血压装置的验证研究。这些研究在设计、环境、方法、测量方案和样本量方面具有相当大的异质性。因此,目前,kiosk血压测量的临床应用是不确定的。该ESH共识声明承认kiosk血压测量作为一种无监督自我测量的新方法,在表面健康人群的机会性高血压筛查和诊断为高血压的人的长期监测的背景下具有潜力。提供了kiosk BP监测仪的设计、验证、功能和使用要求,以及其在临床实践中最佳实施的未决研究问题。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Blood pressure measurement at kiosks in public spaces: systematic review and consensus statement by the European Society of Hypertension Working Group on Blood Pressure Monitoring and Cardiovascular Variability endorsed by the International Society of Hypertension and the World Hypertension League.

Kiosk devices for unsupervised self-measurement of blood pressure (BP) are being used in public spaces and healthcare settings in several countries. This statement by the European Society of Hypertension (ESH) Working Group on BP Monitoring and Cardiovascular Variability provides a review of the published evidence on kiosk BP devices and consensus recommendations for their requirements and clinical use. A systematic literature search identified 54 relevant studies. Kiosk BP measurements appeared to be close to office BP [mean difference systolic 0.2 mmHg (95% confidence intervals -1.3 to 1.8); diastolic -0.4 mmHg (-3.5 to 2.7)], and higher than daytime ambulatory and home BP [mean difference 6.0 mmHg (1.6-10.4)/5.0 (2-8) and 8.1 mmHg (-2.6 to 18.9)/0.2 (-9.6 to 10.0), respectively]. Randomized or observational studies using kiosk BP measurements for hypertension screening or for assessing hypertension control were also included, as well as studies investigating users' and healthcare professionals' opinions, acceptability, and perspectives regarding kiosk BP measurements, and validation studies of kiosk BP devices. These studies had considerable heterogeneity in design, setting, methodology, measurement protocol, and sample size. Thus, at present, the clinical utility of kiosk BP measurements is uncertain. This ESH consensus statement acknowledges the potential of kiosk BP measurement as an emerging method for unsupervised self-measurement in the context of opportunistic screening for hypertension in apparently healthy people and the long-term monitoring of people with diagnosed hypertension. Requirements for the design, validation, function, and use of kiosk BP monitors are provided, together with the pending research questions on their optimal implementation in clinical practice.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Hypertension
Journal of Hypertension 医学-外周血管病
CiteScore
7.90
自引率
6.10%
发文量
1389
审稿时长
3 months
期刊介绍: The Journal of Hypertension publishes papers reporting original clinical and experimental research which are of a high standard and which contribute to the advancement of knowledge in the field of hypertension. The Journal publishes full papers, reviews or editorials (normally by invitation), and correspondence.
期刊最新文献
Impact of centrally acting sympatholytic agents on the blood pressure response to renal denervation. Autonomic control as a mechanism of prolonged hypotension after acute aerobic exercise in individuals with normal and elevated blood pressure: a systematic review and meta-analysis. Aldosterone synthase inhibitors for resistant or uncontrolled hypertension: a network meta-analysis of randomized clinical trials. Actigraphy-derived sleep duration and its association with blood pressure: NHANES 2011 to 2014. Interaction between white coat effect and hypertension on arterial stiffness.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1