IF 3.4 3区 医学 Q2 ONCOLOGY Practical Radiation Oncology Pub Date : 2025-02-12 DOI:10.1016/j.prro.2025.01.013
Juan-Francisco Calvo-Ortega, Coral Laosa-Bello, Sandra Moragues-Femenía, José Torices-Caballero, Miguel Pozo-Massó, Adam Jones, Marcelino Hermida-López
{"title":"ONLINE ADAPTIVE FIVE-FRACTION ABLATIVE RADIOTHERAPY FOR PROSTATE CANCER USING A CONVENTIONAL LINEAR ACCELERATOR.","authors":"Juan-Francisco Calvo-Ortega, Coral Laosa-Bello, Sandra Moragues-Femenía, José Torices-Caballero, Miguel Pozo-Massó, Adam Jones, Marcelino Hermida-López","doi":"10.1016/j.prro.2025.01.013","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>To assess the dosimetric results of an online adaptive stereotactic body radiotherapy (SBRT) program to treat patients with prostate cancer using a conventional linear accelerator.</p><p><strong>Methods and materials: </strong>Prostate SBRT with five fractions is performed at the XXXX using an online adaptive method previously described (XXXX). A CBCT based adaptive \"plan-of-the-day\" (POD) is generated for each treatment fraction, which consists of a single volumetric modulated arc therapy. A dosimetric evaluation of the PODs was performed for the first twenty patients and included analysis of the target (prostate), organs-at-risks (OARs), and patient-specific quality assurance (PSQA). Each of the PODs was also compared with the corresponding conventional image-guided radiotherapy (IGRT) method. Finally, the adaptive treatment timing is analyzed for the one hundred PODs in this study RESULTS: The online adaptive treatment method ensured optimal target coverage in all treatment fractions for all patients. However, the simulated IGRT plans did not result in adequate prostate coverage (V40 Gy ≥ 95%) in 70% of fractions. Small average differences between PODs and IGRT plans were found in the OARs. The dose sparing in the rectum and bladder provided by some simulated IGRT plans, was associated with a compromised prostate coverage. The PSQA resulted in an excellent agreement between the online-calculated plans and the independent dose checks performed for all one hundred PODs. The average duration of the plan adaptation was 20.1 ± 6.1 minutes and the average overall session time including adaptation and treatment delivery was 26.4 ± 33.2 minutes.</p><p><strong>Conclusions: </strong>This study demonstrates The online adaptive program using a conventional linac to treat prostate cancer described in this study is clinically feasible and in adherence with the acceptance criteria set by the PACE B.</p><p><strong>Trial: </strong></p>","PeriodicalId":54245,"journal":{"name":"Practical Radiation Oncology","volume":" ","pages":""},"PeriodicalIF":3.4000,"publicationDate":"2025-02-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Practical Radiation Oncology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.prro.2025.01.013","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ONCOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:评估使用传统直线加速器治疗前列腺癌患者的在线自适应立体定向体放射治疗(SBRT)计划的剂量测定结果:在 XXXX 使用之前描述过的在线自适应方法(XXXX)进行前列腺 SBRT,共分五次。为每个治疗部分生成基于 CBCT 的自适应 "当日计划"(POD),其中包括单次容积调制弧治疗。对前二十名患者的 POD 进行了剂量学评估,包括目标(前列腺)、风险器官(OAR)和患者特定质量保证(PSQA)分析。每个 POD 还与相应的传统图像引导放射治疗 (IGRT) 方法进行了比较。最后,分析了本研究中 100 个 POD 的自适应治疗时机 结果:在线自适应治疗方法确保了所有患者在所有治疗分次中的最佳靶点覆盖率。然而,模拟 IGRT 计划在 70% 的分次治疗中没有实现足够的前列腺覆盖率(V40 Gy ≥ 95%)。POD和IGRT计划在OAR中的平均差异较小。一些模拟 IGRT 方案在直肠和膀胱中提供了剂量疏导,但前列腺覆盖率却受到了影响。PSQA 的结果是,在线计算的计划与对所有 100 个 POD 进行的独立剂量检查结果非常一致。计划适应的平均持续时间为 20.1 ± 6.1 分钟,包括适应和治疗在内的整个疗程的平均时间为 26.4 ± 33.2 分钟:本研究表明,本研究中描述的使用传统linac治疗前列腺癌的在线自适应程序在临床上是可行的,并且符合PACE B.Trial设定的验收标准:
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
ONLINE ADAPTIVE FIVE-FRACTION ABLATIVE RADIOTHERAPY FOR PROSTATE CANCER USING A CONVENTIONAL LINEAR ACCELERATOR.

Aim: To assess the dosimetric results of an online adaptive stereotactic body radiotherapy (SBRT) program to treat patients with prostate cancer using a conventional linear accelerator.

Methods and materials: Prostate SBRT with five fractions is performed at the XXXX using an online adaptive method previously described (XXXX). A CBCT based adaptive "plan-of-the-day" (POD) is generated for each treatment fraction, which consists of a single volumetric modulated arc therapy. A dosimetric evaluation of the PODs was performed for the first twenty patients and included analysis of the target (prostate), organs-at-risks (OARs), and patient-specific quality assurance (PSQA). Each of the PODs was also compared with the corresponding conventional image-guided radiotherapy (IGRT) method. Finally, the adaptive treatment timing is analyzed for the one hundred PODs in this study RESULTS: The online adaptive treatment method ensured optimal target coverage in all treatment fractions for all patients. However, the simulated IGRT plans did not result in adequate prostate coverage (V40 Gy ≥ 95%) in 70% of fractions. Small average differences between PODs and IGRT plans were found in the OARs. The dose sparing in the rectum and bladder provided by some simulated IGRT plans, was associated with a compromised prostate coverage. The PSQA resulted in an excellent agreement between the online-calculated plans and the independent dose checks performed for all one hundred PODs. The average duration of the plan adaptation was 20.1 ± 6.1 minutes and the average overall session time including adaptation and treatment delivery was 26.4 ± 33.2 minutes.

Conclusions: This study demonstrates The online adaptive program using a conventional linac to treat prostate cancer described in this study is clinically feasible and in adherence with the acceptance criteria set by the PACE B.

Trial:

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Practical Radiation Oncology
Practical Radiation Oncology Medicine-Radiology, Nuclear Medicine and Imaging
CiteScore
5.20
自引率
6.10%
发文量
177
审稿时长
34 days
期刊介绍: The overarching mission of Practical Radiation Oncology is to improve the quality of radiation oncology practice. PRO''s purpose is to document the state of current practice, providing background for those in training and continuing education for practitioners, through discussion and illustration of new techniques, evaluation of current practices, and publication of case reports. PRO strives to provide its readers content that emphasizes knowledge "with a purpose." The content of PRO includes: Original articles focusing on patient safety, quality measurement, or quality improvement initiatives Original articles focusing on imaging, contouring, target delineation, simulation, treatment planning, immobilization, organ motion, and other practical issues ASTRO guidelines, position papers, and consensus statements Essays that highlight enriching personal experiences in caring for cancer patients and their families.
期刊最新文献
Variations in radiotherapy delineation of the lateral compartments in patients with rectal cancer: results after an updated national guideline. The Impact of Margin Expansions on Local Control and Radionecrosis Following Stereotactic Radiosurgery for Brain Metastases: A Systematic Review and Meta-Analysis. ONLINE ADAPTIVE FIVE-FRACTION ABLATIVE RADIOTHERAPY FOR PROSTATE CANCER USING A CONVENTIONAL LINEAR ACCELERATOR. Radiation Reflection Rounds: A Departmental Initiative for Staff Well-being. Neoadjuvant SBRT plus Elective Nodal Irradiation with Concurrent Capecitabine for Patients with Resectable Pancreatic Cancer: Survival Analysis of a Prospective Phase 1 Trial.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1