{"title":"基于气体驱动流动聚焦的单细胞/颗粒样品导入装置","authors":"Huaiyi Chen, Jinhui Liu, Yu Zhao, Haitao Xu, Weiliang Liu, Zhi Xing, Fei Tang, Sichun Zhang, Xinrong Zhang","doi":"10.1021/acs.analchem.4c06466","DOIUrl":null,"url":null,"abstract":"Mass cytometry is considered the second generation of flow cytometry technology, which uses metal-labeled antibodies instead of traditional fluorescent antibodies and can measure much more markers from a single cell simultaneously. However, due to frequent clogging of the capillary and nebulizer, it is still a complicated task to perform the sample introduction smoothly for a long-term determination. Herein, a plug-and-play sample introduction device for mass cytometry analysis was developed based on a gas-driven flow focusing protocol. The device is integrated with a virtual hole to generate liquid jet and omit a conventional nebulizer. Single-cell monodispersion can be achieved by liquid jet breakup instead of the commonly used nebulization by the Venturi effect, thus avoiding clogging of thin central capillary. The device has high universality and compatibility and can be plug-and-play on a mass cytometry instrument or common inductively coupled plasma mass spectrometry for single-cell or single-particle determination. High-speed microscopy imaging was used to capture and study the dynamic processes of monodispersion on microsphere suspensions achieved by the device. We also compared the analysis capabilities when using the device and a conventional nebulizer in mass cytometry analysis of four element calibration beads and cell samples. The results obtained by using the flow focusing device and the conventional nebulizer show great consistency, which means the device has no negative impact on the detection performance of mass cytometry and single-cell/particle monodispersion can be achieved without clogging.","PeriodicalId":27,"journal":{"name":"Analytical Chemistry","volume":"49 1","pages":""},"PeriodicalIF":7.3000,"publicationDate":"2025-02-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Single-Cell/Particle Sample Introduction Device for Mass Cytometry Based on Gas-Driven Flow Focusing\",\"authors\":\"Huaiyi Chen, Jinhui Liu, Yu Zhao, Haitao Xu, Weiliang Liu, Zhi Xing, Fei Tang, Sichun Zhang, Xinrong Zhang\",\"doi\":\"10.1021/acs.analchem.4c06466\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Mass cytometry is considered the second generation of flow cytometry technology, which uses metal-labeled antibodies instead of traditional fluorescent antibodies and can measure much more markers from a single cell simultaneously. However, due to frequent clogging of the capillary and nebulizer, it is still a complicated task to perform the sample introduction smoothly for a long-term determination. Herein, a plug-and-play sample introduction device for mass cytometry analysis was developed based on a gas-driven flow focusing protocol. The device is integrated with a virtual hole to generate liquid jet and omit a conventional nebulizer. Single-cell monodispersion can be achieved by liquid jet breakup instead of the commonly used nebulization by the Venturi effect, thus avoiding clogging of thin central capillary. The device has high universality and compatibility and can be plug-and-play on a mass cytometry instrument or common inductively coupled plasma mass spectrometry for single-cell or single-particle determination. High-speed microscopy imaging was used to capture and study the dynamic processes of monodispersion on microsphere suspensions achieved by the device. We also compared the analysis capabilities when using the device and a conventional nebulizer in mass cytometry analysis of four element calibration beads and cell samples. The results obtained by using the flow focusing device and the conventional nebulizer show great consistency, which means the device has no negative impact on the detection performance of mass cytometry and single-cell/particle monodispersion can be achieved without clogging.\",\"PeriodicalId\":27,\"journal\":{\"name\":\"Analytical Chemistry\",\"volume\":\"49 1\",\"pages\":\"\"},\"PeriodicalIF\":7.3000,\"publicationDate\":\"2025-02-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Analytical Chemistry\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1021/acs.analchem.4c06466\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Chemistry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1021/acs.analchem.4c06466","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

大规模细胞术被认为是第二代流式细胞术技术,它使用金属标记抗体代替传统的荧光抗体,可以同时从单个细胞中测量更多的标记物。然而,由于毛细管和雾化器经常堵塞,为了长期测定,顺利进行样品导入仍然是一项复杂的任务。在此,基于气体驱动的流动聚焦协议,开发了一种即插即用的样品导入装置,用于细胞计数分析。该装置集成了一个虚拟孔来产生液体射流,省去了传统的雾化器。单细胞单分散可以通过液体射流破碎来实现,而不是通常使用的文丘里效应雾化,从而避免了薄中央毛细管的堵塞。该设备具有很高的通用性和兼容性,可以即插即用在质量细胞仪或普通的电感耦合等离子体质谱上进行单细胞或单颗粒测定。利用高速显微成像技术捕捉并研究了该装置在微球悬浮液上单色散的动态过程。我们还比较了使用该设备和传统雾化器对四元素校准珠和细胞样品进行质量细胞分析时的分析能力。流动聚焦装置与常规雾化器的检测结果一致性好,对细胞计数检测性能无负面影响,可实现单细胞/颗粒单分散而不堵塞。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Single-Cell/Particle Sample Introduction Device for Mass Cytometry Based on Gas-Driven Flow Focusing
Mass cytometry is considered the second generation of flow cytometry technology, which uses metal-labeled antibodies instead of traditional fluorescent antibodies and can measure much more markers from a single cell simultaneously. However, due to frequent clogging of the capillary and nebulizer, it is still a complicated task to perform the sample introduction smoothly for a long-term determination. Herein, a plug-and-play sample introduction device for mass cytometry analysis was developed based on a gas-driven flow focusing protocol. The device is integrated with a virtual hole to generate liquid jet and omit a conventional nebulizer. Single-cell monodispersion can be achieved by liquid jet breakup instead of the commonly used nebulization by the Venturi effect, thus avoiding clogging of thin central capillary. The device has high universality and compatibility and can be plug-and-play on a mass cytometry instrument or common inductively coupled plasma mass spectrometry for single-cell or single-particle determination. High-speed microscopy imaging was used to capture and study the dynamic processes of monodispersion on microsphere suspensions achieved by the device. We also compared the analysis capabilities when using the device and a conventional nebulizer in mass cytometry analysis of four element calibration beads and cell samples. The results obtained by using the flow focusing device and the conventional nebulizer show great consistency, which means the device has no negative impact on the detection performance of mass cytometry and single-cell/particle monodispersion can be achieved without clogging.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Analytical Chemistry
Analytical Chemistry 化学-分析化学
CiteScore
12.10
自引率
12.20%
发文量
1949
审稿时长
1.4 months
期刊介绍: Analytical Chemistry, a peer-reviewed research journal, focuses on disseminating new and original knowledge across all branches of analytical chemistry. Fundamental articles may explore general principles of chemical measurement science and need not directly address existing or potential analytical methodology. They can be entirely theoretical or report experimental results. Contributions may cover various phases of analytical operations, including sampling, bioanalysis, electrochemistry, mass spectrometry, microscale and nanoscale systems, environmental analysis, separations, spectroscopy, chemical reactions and selectivity, instrumentation, imaging, surface analysis, and data processing. Papers discussing known analytical methods should present a significant, original application of the method, a notable improvement, or results on an important analyte.
期刊最新文献
An In Situ Gelled PCA-Na/Gelatin Hydrogel Plant Wearable Sensor Patch Based on Synergistic Enhancement Strategy for Atrazine Detection. Prostate Cancer Detection in Urine Using the Fusion of LIBS, FTIR Dual Spectra and FTIR Reconstructed Image. Multimodal Detection of α-Amanitin Using a Cell-Free Biosensing Platform. Ferroptosis Revealed by a Bifunctional Nanopipette Sensing the Intracellular Iron-Reactive Oxygen under Dibenzothiophene Exposure. Machine Learning-Assisted 3D Envelope-Enhanced SERS Platform for Detection and Classification of Multiple Coexisting Pollutants.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1