纤维增强与传统不锈钢固定固位器的双酚A释放:体外研究。

IF 5.2 3区 医学 Q1 ENGINEERING, BIOMEDICAL Journal of Functional Biomaterials Pub Date : 2025-02-17 DOI:10.3390/jfb16020068
Efthimia Tsoukala, Niki Maragou, Andriani-Paraskevi Antonelaki, Nikolaos Thomaidis, Iosif Sifakakis
{"title":"纤维增强与传统不锈钢固定固位器的双酚A释放:体外研究。","authors":"Efthimia Tsoukala, Niki Maragou, Andriani-Paraskevi Antonelaki, Nikolaos Thomaidis, Iosif Sifakakis","doi":"10.3390/jfb16020068","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>The objectives of this study were to investigate in vitro BPA release from two common fiberglass fixed lingual canine-to-canine retainers and to compare these amounts with those released from a conventional multistranded stainless-steel orthodontic retainer.</p><p><strong>Methods: </strong>Fifty-four recently extracted teeth were divided into groups of six teeth each, formed in an arch shape. Three different retainer types were evaluated: Ribbond, EverStick Ortho and Wildcut wire. Three identical specimens were constructed for each retainer type. BPA release was determined with validated the liquid chromatography-tandem mass spectrometry method at 1 and 24 h, as well as at 7, 14 and 30 days. The method's limits of detection and quantification were 0.32 ng/mL and 0.96 ng/mL, respectively. A two-way mixed, repeated-measures analysis of variance with Greenhouse-Geisser correction was employed to verify the existence of any significant differences.</p><p><strong>Results: </strong>Higher levels of BPA were released from the polyethylene fiber and glass fiber retainer in comparison with the conventional retainer in the present study. The differences between the systems over time were not statistically significant at the 95% confidence level.</p><p><strong>Conclusions: </strong>In vitro BPA release during the first month did not differ between the examined retainer types. The highest BPA concentrations were observed at 1 month.</p>","PeriodicalId":15767,"journal":{"name":"Journal of Functional Biomaterials","volume":"16 2","pages":""},"PeriodicalIF":5.2000,"publicationDate":"2025-02-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11856908/pdf/","citationCount":"0","resultStr":"{\"title\":\"Bisphenol A Release from Fiber-Reinforced vs. Conventional Stainless-Steel Fixed Retainers: An In Vitro Study.\",\"authors\":\"Efthimia Tsoukala, Niki Maragou, Andriani-Paraskevi Antonelaki, Nikolaos Thomaidis, Iosif Sifakakis\",\"doi\":\"10.3390/jfb16020068\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>The objectives of this study were to investigate in vitro BPA release from two common fiberglass fixed lingual canine-to-canine retainers and to compare these amounts with those released from a conventional multistranded stainless-steel orthodontic retainer.</p><p><strong>Methods: </strong>Fifty-four recently extracted teeth were divided into groups of six teeth each, formed in an arch shape. Three different retainer types were evaluated: Ribbond, EverStick Ortho and Wildcut wire. Three identical specimens were constructed for each retainer type. BPA release was determined with validated the liquid chromatography-tandem mass spectrometry method at 1 and 24 h, as well as at 7, 14 and 30 days. The method's limits of detection and quantification were 0.32 ng/mL and 0.96 ng/mL, respectively. A two-way mixed, repeated-measures analysis of variance with Greenhouse-Geisser correction was employed to verify the existence of any significant differences.</p><p><strong>Results: </strong>Higher levels of BPA were released from the polyethylene fiber and glass fiber retainer in comparison with the conventional retainer in the present study. The differences between the systems over time were not statistically significant at the 95% confidence level.</p><p><strong>Conclusions: </strong>In vitro BPA release during the first month did not differ between the examined retainer types. The highest BPA concentrations were observed at 1 month.</p>\",\"PeriodicalId\":15767,\"journal\":{\"name\":\"Journal of Functional Biomaterials\",\"volume\":\"16 2\",\"pages\":\"\"},\"PeriodicalIF\":5.2000,\"publicationDate\":\"2025-02-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11856908/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Functional Biomaterials\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.3390/jfb16020068\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Functional Biomaterials","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/jfb16020068","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究的目的是调查两种常见的玻璃纤维固定舌牙固位器的体外BPA释放量,并将其与传统的多链不锈钢正畸固位器的释放量进行比较。方法:将54颗近期拔除的牙齿分为组,每组6颗牙齿呈弓形排列。评估了三种不同的固位器类型:带状固位器、EverStick Ortho固位器和Wildcut wire固位器。为每种固位器类型构建三个相同的标本。采用验证的液相色谱-串联质谱法测定BPA在1、24 h、7、14、30 d的释放量。方法的检测限和定量限分别为0.32 ng/mL和0.96 ng/mL。采用温室-盖瑟校正的双向混合、重复测量方差分析来验证任何显著差异的存在。结果:在本研究中,聚乙烯纤维和玻璃纤维固位器释放的BPA含量高于传统固位器。系统间随时间的差异在95%置信水平上无统计学意义。结论:两种固位体在第一个月内的体外双酚a释放量没有差异。1个月时BPA浓度最高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Bisphenol A Release from Fiber-Reinforced vs. Conventional Stainless-Steel Fixed Retainers: An In Vitro Study.

Objectives: The objectives of this study were to investigate in vitro BPA release from two common fiberglass fixed lingual canine-to-canine retainers and to compare these amounts with those released from a conventional multistranded stainless-steel orthodontic retainer.

Methods: Fifty-four recently extracted teeth were divided into groups of six teeth each, formed in an arch shape. Three different retainer types were evaluated: Ribbond, EverStick Ortho and Wildcut wire. Three identical specimens were constructed for each retainer type. BPA release was determined with validated the liquid chromatography-tandem mass spectrometry method at 1 and 24 h, as well as at 7, 14 and 30 days. The method's limits of detection and quantification were 0.32 ng/mL and 0.96 ng/mL, respectively. A two-way mixed, repeated-measures analysis of variance with Greenhouse-Geisser correction was employed to verify the existence of any significant differences.

Results: Higher levels of BPA were released from the polyethylene fiber and glass fiber retainer in comparison with the conventional retainer in the present study. The differences between the systems over time were not statistically significant at the 95% confidence level.

Conclusions: In vitro BPA release during the first month did not differ between the examined retainer types. The highest BPA concentrations were observed at 1 month.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Functional Biomaterials
Journal of Functional Biomaterials Engineering-Biomedical Engineering
CiteScore
4.60
自引率
4.20%
发文量
226
审稿时长
11 weeks
期刊介绍: Journal of Functional Biomaterials (JFB, ISSN 2079-4983) is an international and interdisciplinary scientific journal that publishes regular research papers (articles), reviews and short communications about applications of materials for biomedical use. JFB covers subjects from chemistry, pharmacy, biology, physics over to engineering. The journal focuses on the preparation, performance and use of functional biomaterials in biomedical devices and their behaviour in physiological environments. Our aim is to encourage scientists to publish their results in as much detail as possible. Therefore, there is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced. Several topical special issues will be published. Scope: adhesion, adsorption, biocompatibility, biohybrid materials, bio-inert materials, biomaterials, biomedical devices, biomimetic materials, bone repair, cardiovascular devices, ceramics, composite materials, dental implants, dental materials, drug delivery systems, functional biopolymers, glasses, hyper branched polymers, molecularly imprinted polymers (MIPs), nanomedicine, nanoparticles, nanotechnology, natural materials, self-assembly smart materials, stimuli responsive materials, surface modification, tissue devices, tissue engineering, tissue-derived materials, urological devices.
期刊最新文献
Numerical Simulation of Bone Defect Repair Using a Triply Periodic Minimal Surface Scaffold. Optimal Selection of Biodegradable Polymer Composites for Load-Bearing Bone Tissue Engineering: A Hybrid Fuzzy AHP-TOPSIS Framework with Sensitivity-Based Robustness Analysis. Dimensional Stability of Polymer and Titanium Implant Scan Bodies After Repeated Steam Sterilization: A High-Resolution 3D Metrological In Vitro Study. An Injectable Biopolymer Hydrogel Complex (PN/HA/B3) for Facial Skin Redensification and General Rejuvenation: Clinical Report on Device Safety and Efficacy. Histomorphometric Evaluation of Subchronic and Chronic Effects of Novel Experimental Calcium Aluminate- and Calcium Silicate-Based Dental Cement Materials on Rat Liver, Kidney, Brain, and Spleen Tissues.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1