cool透析液与标准透析液血液透析患者的临床结果:一项系统回顾和荟萃分析。

IF 3.8 3区 医学 Q1 UROLOGY & NEPHROLOGY American Journal of Nephrology Pub Date : 2025-01-01 Epub Date: 2025-03-03 DOI:10.1159/000544924
Chander Subhash, Subhash Chander, Rabia Latif, Ahmad Bin Aamir, Fnu Sorath, Abhi Chand Lohana, Mohammed Yaqub Nadeem, Om Parkash
{"title":"cool透析液与标准透析液血液透析患者的临床结果:一项系统回顾和荟萃分析。","authors":"Chander Subhash, Subhash Chander, Rabia Latif, Ahmad Bin Aamir, Fnu Sorath, Abhi Chand Lohana, Mohammed Yaqub Nadeem, Om Parkash","doi":"10.1159/000544924","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Clinical practice guidelines recommend lower (35.0°C-35.5°C) instead of standard dialysate temperature (36.5°C-37.0°C) to mitigate the risk of intradialytic hypotension. However, many studies have been available since the recommendations were published. Hence, the current study aimed to provide an updated meta-analysis of clinical outcomes with cold versus standard dialysate.</p><p><strong>Methods: </strong>This systematic review and meta-analysis included eligible articles indexed in PubMed, Cochrane Library, Web of Science, and Scopus, evaluating the effects of cooled versus standard dialysate in hemodialysis patients. The primary outcomes were intradialytic hypotension, mean arterial pressure, thermal-related discomfort, and body temperature changes. A random-effects model was used for all outcomes due to high heterogeneity (I2: intradialytic hypotension = 60%, mean arterial pressure = 72%, symptoms of discomfort = 41%, decrease in body temperature = 87%). Sensitivity analysis was performed using the \"leave-one-out\" approach, and the Cochrane risk-of-bias tool was used to assess study quality. A total of 31 studies were included. Pooled results indicate that cooled dialysis was associated with a lower risk of intradialytic hypotension (RR 0.67; 95% CI: 0.48-0.93; p = 0.02) and higher mean arterial pressure (MD 7.18; 95% CI: 3.79-10.58; p < 0.01). However, cooled dialysis was associated with a higher risk of discomfort (RR 1.55; 95% CI: 1.25-1.93; p < 0.01) and a significant decrease in body temperature (MD -0.29; 95% CI: -0.52 to -0.05; p = 0.02). This systematic review and meta-analysis is registered in PROSPERO under ID CRD42024589307.</p><p><strong>Conclusions: </strong>Using cooled dialysate might be a simple approach to reduce interdialytic hypotension risk and increase mean arterial pressure, albeit at the cost of patient discomfort. The limitations associated with the quality of included studies underscore the need for high-quality, multicenter studies with large/diverse study populations.</p>","PeriodicalId":7570,"journal":{"name":"American Journal of Nephrology","volume":" ","pages":"555-570"},"PeriodicalIF":3.8000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Clinical Outcomes of Patients undergoing Hemodialysis with Cool versus Standard Dialysate: A Systematic Review and Meta-Analysis.\",\"authors\":\"Chander Subhash, Subhash Chander, Rabia Latif, Ahmad Bin Aamir, Fnu Sorath, Abhi Chand Lohana, Mohammed Yaqub Nadeem, Om Parkash\",\"doi\":\"10.1159/000544924\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>Clinical practice guidelines recommend lower (35.0°C-35.5°C) instead of standard dialysate temperature (36.5°C-37.0°C) to mitigate the risk of intradialytic hypotension. However, many studies have been available since the recommendations were published. Hence, the current study aimed to provide an updated meta-analysis of clinical outcomes with cold versus standard dialysate.</p><p><strong>Methods: </strong>This systematic review and meta-analysis included eligible articles indexed in PubMed, Cochrane Library, Web of Science, and Scopus, evaluating the effects of cooled versus standard dialysate in hemodialysis patients. The primary outcomes were intradialytic hypotension, mean arterial pressure, thermal-related discomfort, and body temperature changes. A random-effects model was used for all outcomes due to high heterogeneity (I2: intradialytic hypotension = 60%, mean arterial pressure = 72%, symptoms of discomfort = 41%, decrease in body temperature = 87%). Sensitivity analysis was performed using the \\\"leave-one-out\\\" approach, and the Cochrane risk-of-bias tool was used to assess study quality. A total of 31 studies were included. Pooled results indicate that cooled dialysis was associated with a lower risk of intradialytic hypotension (RR 0.67; 95% CI: 0.48-0.93; p = 0.02) and higher mean arterial pressure (MD 7.18; 95% CI: 3.79-10.58; p < 0.01). However, cooled dialysis was associated with a higher risk of discomfort (RR 1.55; 95% CI: 1.25-1.93; p < 0.01) and a significant decrease in body temperature (MD -0.29; 95% CI: -0.52 to -0.05; p = 0.02). This systematic review and meta-analysis is registered in PROSPERO under ID CRD42024589307.</p><p><strong>Conclusions: </strong>Using cooled dialysate might be a simple approach to reduce interdialytic hypotension risk and increase mean arterial pressure, albeit at the cost of patient discomfort. The limitations associated with the quality of included studies underscore the need for high-quality, multicenter studies with large/diverse study populations.</p>\",\"PeriodicalId\":7570,\"journal\":{\"name\":\"American Journal of Nephrology\",\"volume\":\" \",\"pages\":\"555-570\"},\"PeriodicalIF\":3.8000,\"publicationDate\":\"2025-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"American Journal of Nephrology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1159/000544924\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/3/3 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"UROLOGY & NEPHROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"American Journal of Nephrology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1159/000544924","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/3/3 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"UROLOGY & NEPHROLOGY","Score":null,"Total":0}
引用次数: 0

摘要

基本原理及目的:临床实践指南建议降低透析液温度(35.0°C-35.5°C),而不是标准透析液温度(36.5°C-37.0°C),以降低透析液中低血压的风险。然而,自这些建议发表以来,已有许多研究可供参考。因此,本研究旨在提供冷透析与标准透析临床结果的最新荟萃分析。研究设计:对PubMed、Cochrane、Web of Science和Scopus收录的符合条件的文章进行系统评价和荟萃分析。参与者:血液透析患者暴露:冷却与标准透析液。结果:分析性低血压,平均动脉压,热相关不适和体温。分析方法:由于异质性高,所有结果均采用随机效应模型(I2:透析间期低血压=60%,平均动脉压=72%,不适症状=41%,体温下降=87%)。敏感性分析采用“留一”法,评价研究质量采用Cochrane偏倚风险工具。结果:来自31项研究的汇总数据表明,冷却透析可能与较低的溶栓性低血压风险[RR 0.67 (95%CI 0.48-0.93), p=0.02]和较高的平均动脉压[MD 7.18 (95%CI 3.79-10.58)相关。局限性:大多数纳入的研究来自十多年前,参与者规模较小,未报告其他关键的长期结局,如死亡率、心血管事件、治疗中断或住院率。结论:使用冷却的透析液可能是一种降低透析间期低血压风险和增加平均动脉压的简单方法,尽管以患者不适为代价。纳入研究的质量方面的局限性强调了对大/多样化研究人群的高质量、多中心研究的需求。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Clinical Outcomes of Patients undergoing Hemodialysis with Cool versus Standard Dialysate: A Systematic Review and Meta-Analysis.

Introduction: Clinical practice guidelines recommend lower (35.0°C-35.5°C) instead of standard dialysate temperature (36.5°C-37.0°C) to mitigate the risk of intradialytic hypotension. However, many studies have been available since the recommendations were published. Hence, the current study aimed to provide an updated meta-analysis of clinical outcomes with cold versus standard dialysate.

Methods: This systematic review and meta-analysis included eligible articles indexed in PubMed, Cochrane Library, Web of Science, and Scopus, evaluating the effects of cooled versus standard dialysate in hemodialysis patients. The primary outcomes were intradialytic hypotension, mean arterial pressure, thermal-related discomfort, and body temperature changes. A random-effects model was used for all outcomes due to high heterogeneity (I2: intradialytic hypotension = 60%, mean arterial pressure = 72%, symptoms of discomfort = 41%, decrease in body temperature = 87%). Sensitivity analysis was performed using the "leave-one-out" approach, and the Cochrane risk-of-bias tool was used to assess study quality. A total of 31 studies were included. Pooled results indicate that cooled dialysis was associated with a lower risk of intradialytic hypotension (RR 0.67; 95% CI: 0.48-0.93; p = 0.02) and higher mean arterial pressure (MD 7.18; 95% CI: 3.79-10.58; p < 0.01). However, cooled dialysis was associated with a higher risk of discomfort (RR 1.55; 95% CI: 1.25-1.93; p < 0.01) and a significant decrease in body temperature (MD -0.29; 95% CI: -0.52 to -0.05; p = 0.02). This systematic review and meta-analysis is registered in PROSPERO under ID CRD42024589307.

Conclusions: Using cooled dialysate might be a simple approach to reduce interdialytic hypotension risk and increase mean arterial pressure, albeit at the cost of patient discomfort. The limitations associated with the quality of included studies underscore the need for high-quality, multicenter studies with large/diverse study populations.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
American Journal of Nephrology
American Journal of Nephrology 医学-泌尿学与肾脏学
CiteScore
7.50
自引率
2.40%
发文量
74
审稿时长
4-8 weeks
期刊介绍: The ''American Journal of Nephrology'' is a peer-reviewed journal that focuses on timely topics in both basic science and clinical research. Papers are divided into several sections, including:
期刊最新文献
Comment on 'Lower Risk of Acute Kidney Injury in Hospitalized Patients Treated With SGLT-2 Inhibitors: A Retrospective Matched Cohort Study'. Context-Dependent Prognostic Significance of Total Iron-Binding Capacity by Nutritional and Inflammatory Status in Hemodialysis. Safety and Effectiveness of Apixaban Versus Warfarin in Peritoneal Dialysis Patients with Newly Diagnosed Nonvalvular Atrial Fibrillation. Metabolic Syndrome and Risk of Atrial Fibrillation in Chronic Kidney Disease. Adjudicating heart failure as an end point in dialysis trials- more signal, less noise.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1