Q3 Medicine Vestnik oftalmologii Pub Date : 2025-01-01 DOI:10.17116/oftalma202514101128
Kh M Kamilov, N N Zaynutdinov
{"title":"[Long-term outcomes of phakic intraocular lens implantation in high myopia].","authors":"Kh M Kamilov, N N Zaynutdinov","doi":"10.17116/oftalma202514101128","DOIUrl":null,"url":null,"abstract":"<p><p>Refractive anomalies are among the leading ocular conditions affecting the working-age population. One of them - high myopia - can cause severe and irreversible ocular changes, resulting in significant visual impairment or loss.</p><p><strong>Purpose: </strong>This study evaluated changes in vault height of phakic intraocular lenses (PIOL) and intraocular pressure (IOP) following the implantation of the ICL V5 (VICM5) lens in patients with high myopia.</p><p><strong>Material and method: </strong>The study included 60 patients. They were monitored for at least 24 months. Observation included measurement of clinical refraction, uncorrected visual acuity (UCVA), IOP, and the distance between the posterior surface of the optical part of the lens and the anterior surface of the crystalline lens (vault).</p><p><strong>Results: </strong>All surgeries were completed without complications. The safety and efficacy indices were 1.43 and 1.34, respectively. In 97 eyes (86%) with high myopia UCVA was equal to or better than preoperative values. The mean preoperative spherical equivalent was -10.59±3.4 D, which improved postoperatively to -0.5±0.75 D. Subsequently, the spherical equivalent remained within ±0.5 D in 89% of patients. The mean postoperative IOP was 15.86±3.30 mm Hg over the course of the 24-month follow-up. One month post-implantation, the vault height of the spherical lens ICL was 469.3±134.4 µm and 432.6±124.5 µm after 24 months (<i>p</i><0.001).</p><p><strong>Conclusion: </strong>Implantation of the Visian ICL V5 lens is a safe and effective alternative refractive surgery method for the correction of high myopia.</p>","PeriodicalId":23529,"journal":{"name":"Vestnik oftalmologii","volume":"141 1","pages":"28-31"},"PeriodicalIF":0.0000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Vestnik oftalmologii","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17116/oftalma202514101128","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

屈光异常是影响劳动适龄人口的主要眼部疾病之一。目的:本研究评估了高度近视患者在植入 ICL V5 (VICM5) 镜片后,相控人工晶体穹窿高度(PIOL)和眼压(IOP)的变化:研究包括 60 名患者。材料:研究包括 60 名患者,对他们进行了至少 24 个月的监测。观察包括测量临床屈光度、未矫正视力(UCVA)、眼压以及晶状体光学部分后表面与晶状体前表面(穹窿)之间的距离:所有手术均顺利完成,无并发症。安全性和有效性指数分别为 1.43 和 1.34。97只高度近视眼(86%)的UCVA等于或优于术前数值。术前球面等效视力平均值为-10.59±3.4 D,术后改善为-0.5±0.75 D,89%的患者术后球面等效视力保持在±0.5 D以内。在 24 个月的随访期间,术后平均眼压为 15.86±3.30 mm Hg。植入一个月后,球面透镜 ICL 的穹顶高度为 469.3±134.4 µm,24 个月后为 432.6±124.5 µm(p 结论:植入 Visian ICL V5 镜片是矫正高度近视的一种安全有效的屈光手术替代方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[Long-term outcomes of phakic intraocular lens implantation in high myopia].

Refractive anomalies are among the leading ocular conditions affecting the working-age population. One of them - high myopia - can cause severe and irreversible ocular changes, resulting in significant visual impairment or loss.

Purpose: This study evaluated changes in vault height of phakic intraocular lenses (PIOL) and intraocular pressure (IOP) following the implantation of the ICL V5 (VICM5) lens in patients with high myopia.

Material and method: The study included 60 patients. They were monitored for at least 24 months. Observation included measurement of clinical refraction, uncorrected visual acuity (UCVA), IOP, and the distance between the posterior surface of the optical part of the lens and the anterior surface of the crystalline lens (vault).

Results: All surgeries were completed without complications. The safety and efficacy indices were 1.43 and 1.34, respectively. In 97 eyes (86%) with high myopia UCVA was equal to or better than preoperative values. The mean preoperative spherical equivalent was -10.59±3.4 D, which improved postoperatively to -0.5±0.75 D. Subsequently, the spherical equivalent remained within ±0.5 D in 89% of patients. The mean postoperative IOP was 15.86±3.30 mm Hg over the course of the 24-month follow-up. One month post-implantation, the vault height of the spherical lens ICL was 469.3±134.4 µm and 432.6±124.5 µm after 24 months (p<0.001).

Conclusion: Implantation of the Visian ICL V5 lens is a safe and effective alternative refractive surgery method for the correction of high myopia.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Vestnik oftalmologii
Vestnik oftalmologii Medicine-Ophthalmology
CiteScore
0.80
自引率
0.00%
发文量
129
期刊介绍: The journal publishes materials on the diagnosis and treatment of eye diseases, hygiene of vision, prevention of ophthalmic affections, history of Russian ophthalmology, organization of ophthalmological aid to the population, as well as the problems of special equipment. Original scientific articles and surveys on urgent problems of theory and practice of Russian and foreign ophthalmology are published. The journal contains book reviews on ophthalmology, information on the activities of ophthalmologists" scientific societies, chronicle of congresses and conferences.The journal is intended for ophthalmologists and scientific workers dealing with clinical problems of diseases of the eye and physiology of vision.
期刊最新文献
[A modern perspective on the pathogenesis of proliferative diabetic retinopathy]. [Angiographic parameters of the retina after various methods of membrane peeling in the treatment of diabetic maculopathy]. [Association between integrity of foveal photoreceptors and ultimate visual outcome in neovascular age-related macular degeneration]. [Axial displacement of intraocular lens in the postoperative period in hyperopia]. [Choroidal neovascularization associated with choroidal nevi].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1