IF 5.7 2区 医学 Q1 ENDOCRINOLOGY & METABOLISM Diabetes technology & therapeutics Pub Date : 2025-03-11 DOI:10.1089/dia.2024.0560
Yogish C Kudva, Robert J Henderson, Lauren G Kanapka, Ruth S Weinstock, Michael R Rickels, Richard E Pratley, Naomi Chaytor, Kamille Janess, Donna Desjardins, Vishwanath Pattan, Amy J Peleckis, Anna Casu, Shafaq Raza Rizvi, Suzan Bzdick, Keri J Whitaker, Jorge L Jo Kamimoto, Kellee Miller, Craig Kollman, Roy W Beck
{"title":"Automated Insulin Delivery in Elderly with Type 1 Diabetes: A Prespecified Analysis of the Extension Phase.","authors":"Yogish C Kudva, Robert J Henderson, Lauren G Kanapka, Ruth S Weinstock, Michael R Rickels, Richard E Pratley, Naomi Chaytor, Kamille Janess, Donna Desjardins, Vishwanath Pattan, Amy J Peleckis, Anna Casu, Shafaq Raza Rizvi, Suzan Bzdick, Keri J Whitaker, Jorge L Jo Kamimoto, Kellee Miller, Craig Kollman, Roy W Beck","doi":"10.1089/dia.2024.0560","DOIUrl":null,"url":null,"abstract":"<p><p>The Automated Insulin Delivery in Elderly with Type 1 Diabetes (AIDE T1D) trial randomized 82 adults ≥65 years with type 1 diabetes (T1D) to hybrid closed loop (HCL), predictive low glucose suspend (PLGS), and sensor-augmented pump (SAP) therapy in a randomized crossover trial. Seventy-five of the 78 completers joined an extension phase in which they were offered the pump mode of their choice for an additional 3 months. Mean age was 71 ± 4 years (range 65-86 years) and mean duration of T1D was 42 ± 17 years (range 1-68 years). Use of HCL was selected by 91%, PLGS by 8%, and continuous glucose monitoring with injections by 1%. For participants selecting HCL, time-in-range 70-180 mg/dL was similar in the randomized controlled trial and extension phase (mean 75% ± 10%). One severe hypoglycemic event was reported. HCL was preferred over PLGS or SAP and remained effective in older adults with T1D. Clinical Trial Registration: NCT04016662.</p>","PeriodicalId":11159,"journal":{"name":"Diabetes technology & therapeutics","volume":" ","pages":""},"PeriodicalIF":5.7000,"publicationDate":"2025-03-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diabetes technology & therapeutics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1089/dia.2024.0560","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENDOCRINOLOGY & METABOLISM","Score":null,"Total":0}
引用次数: 0

摘要

1 型糖尿病老人胰岛素自动给药(AIDE T1D)试验在随机交叉试验中将 82 名年龄≥65 岁的 1 型糖尿病(T1D)成人随机分配到混合闭环(HCL)、预测性低血糖暂停(PLGS)和传感器增强泵(SAP)疗法中。78 名完成者中有 75 人参加了延长阶段,在延长的 3 个月中,他们可以选择自己喜欢的泵模式。平均年龄为 71 ± 4 岁(65-86 岁不等),T1D 平均病程为 42 ± 17 年(1-68 年不等)。91%的人选择使用 HCL,8%的人选择使用 PLGS,1%的人选择使用注射式持续血糖监测。对于选择 HCL 的参与者,在随机对照试验和扩展阶段,70-180 mg/dL 范围内的时间相似(平均为 75% ± 10%)。报告了一起严重低血糖事件。与 PLGS 或 SAP 相比,HCL 更受青睐,对患有 T1D 的老年人仍然有效。临床试验注册:NCT04016662。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Automated Insulin Delivery in Elderly with Type 1 Diabetes: A Prespecified Analysis of the Extension Phase.

The Automated Insulin Delivery in Elderly with Type 1 Diabetes (AIDE T1D) trial randomized 82 adults ≥65 years with type 1 diabetes (T1D) to hybrid closed loop (HCL), predictive low glucose suspend (PLGS), and sensor-augmented pump (SAP) therapy in a randomized crossover trial. Seventy-five of the 78 completers joined an extension phase in which they were offered the pump mode of their choice for an additional 3 months. Mean age was 71 ± 4 years (range 65-86 years) and mean duration of T1D was 42 ± 17 years (range 1-68 years). Use of HCL was selected by 91%, PLGS by 8%, and continuous glucose monitoring with injections by 1%. For participants selecting HCL, time-in-range 70-180 mg/dL was similar in the randomized controlled trial and extension phase (mean 75% ± 10%). One severe hypoglycemic event was reported. HCL was preferred over PLGS or SAP and remained effective in older adults with T1D. Clinical Trial Registration: NCT04016662.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Diabetes technology & therapeutics
Diabetes technology & therapeutics 医学-内分泌学与代谢
CiteScore
10.60
自引率
14.80%
发文量
145
审稿时长
3-8 weeks
期刊介绍: Diabetes Technology & Therapeutics is the only peer-reviewed journal providing healthcare professionals with information on new devices, drugs, drug delivery systems, and software for managing patients with diabetes. This leading international journal delivers practical information and comprehensive coverage of cutting-edge technologies and therapeutics in the field, and each issue highlights new pharmacological and device developments to optimize patient care.
期刊最新文献
Automated Insulin Delivery in Elderly with Type 1 Diabetes: A Prespecified Analysis of the Extension Phase. Impact of Meal Insulin Bolus Timing and Bedtime Snacking on Continuous Glucose Monitoring-Derived Glycemic Metrics in Hospitalized Inpatients. Phenolic Preservatives Are Not the Sole Cause of Eosinophilic Infiltration at Infusion Pump Sites. Continuous Glucose Monitoring in Type 1 Diabetes, Type 2 Diabetes, and Diabetes During Pregnancy: A Systematic Review with Meta-Analysis of Randomized Controlled Trials. Continuous Glucose Monitoring-Based Titration of Once-Weekly Insulin Icodec in Insulin-Naive Individuals with Type 2 Diabetes (ONWARDS 9): A Phase 3b, Multicenter, Single-Arm, Treat-to-Target Clinical Trial.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1