{"title":"飞秒激光液体光学接口作为低视力光学资源。","authors":"Norton Sakassegawa Yanagimori, Bernardo Kaplan Moscovici, Gicele Rodrigues Chaves Rinaldo, Priscila Ciocler Froiman, Ivan Corso Teixeira","doi":"10.1080/02713683.2025.2478239","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To assess the efficacy of a low-cost optical magnifier created from the repurposed femtosecond laser interface used in cataract surgery to reduce healthcare waste and financial burden for low-vision patients.</p><p><strong>Methods: </strong>This prospective study included 16 Brazilian patients from the Low Vision Department of the Irmandade da Santa Casa de Misericórdia de São Paulo. Participants had visual acuity between +0.5 and +1.3 logMAR and visual field constrictions under 20°. The Catalys<sup>®</sup> femtosecond laser interface lens, usually discarded after surgery, was sterilized and attached to a recyclable support to create a magnifying device. Patients were trained to use it for 30 days. Visual function was assessed with the NEI VFQ-25, and reading performance was measured using the MNREAD-P test.</p><p><strong>Results: </strong>Thirteen patients (81.25%) completed the study. The use of the optical device led to significant improvements in all MNREAD-P parameters. Reading acuity improved from 0.74 ± 0.19 logMAR (20/110 Snellen) to 0.41 ± 0.22 logMAR (20/50 Snellen) (<i>p</i> < 0.001). Critical print size decreased from 0.85 ± 0.19 logMAR (20/140 Snellen) to 0.56 ± 0.24 logMAR (20/70 Snellen) (<i>p</i> < 0.001). Maximum reading speed increased from 41.4 ± 18.0 words per minute (wpm) to 56.2 ± 25.2 wpm (<i>p</i> < 0.001). NEI VFQ-25 scores improved from 32.7 ± 13.8 to 46.9 ± 15.0 (<i>p</i> < 0.001), with increases observed in all subcategories, particularly in \"Reactions to Vision Problems.\"</p><p><strong>Conclusion: </strong>Repurposing the femtosecond laser interface lens as a low-cost magnifier showed promising improvements in reading and visual function for low-vision patients while addressing healthcare waste. Further studies with larger samples are recommended to validate and expand this sustainable approach in visual rehabilitation.</p>","PeriodicalId":10782,"journal":{"name":"Current Eye Research","volume":" ","pages":"719-724"},"PeriodicalIF":1.7000,"publicationDate":"2025-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Femtosecond Laser Liquid Optics Interface as Low Vision Optical Resource.\",\"authors\":\"Norton Sakassegawa Yanagimori, Bernardo Kaplan Moscovici, Gicele Rodrigues Chaves Rinaldo, Priscila Ciocler Froiman, Ivan Corso Teixeira\",\"doi\":\"10.1080/02713683.2025.2478239\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To assess the efficacy of a low-cost optical magnifier created from the repurposed femtosecond laser interface used in cataract surgery to reduce healthcare waste and financial burden for low-vision patients.</p><p><strong>Methods: </strong>This prospective study included 16 Brazilian patients from the Low Vision Department of the Irmandade da Santa Casa de Misericórdia de São Paulo. Participants had visual acuity between +0.5 and +1.3 logMAR and visual field constrictions under 20°. The Catalys<sup>®</sup> femtosecond laser interface lens, usually discarded after surgery, was sterilized and attached to a recyclable support to create a magnifying device. Patients were trained to use it for 30 days. Visual function was assessed with the NEI VFQ-25, and reading performance was measured using the MNREAD-P test.</p><p><strong>Results: </strong>Thirteen patients (81.25%) completed the study. The use of the optical device led to significant improvements in all MNREAD-P parameters. Reading acuity improved from 0.74 ± 0.19 logMAR (20/110 Snellen) to 0.41 ± 0.22 logMAR (20/50 Snellen) (<i>p</i> < 0.001). Critical print size decreased from 0.85 ± 0.19 logMAR (20/140 Snellen) to 0.56 ± 0.24 logMAR (20/70 Snellen) (<i>p</i> < 0.001). Maximum reading speed increased from 41.4 ± 18.0 words per minute (wpm) to 56.2 ± 25.2 wpm (<i>p</i> < 0.001). NEI VFQ-25 scores improved from 32.7 ± 13.8 to 46.9 ± 15.0 (<i>p</i> < 0.001), with increases observed in all subcategories, particularly in \\\"Reactions to Vision Problems.\\\"</p><p><strong>Conclusion: </strong>Repurposing the femtosecond laser interface lens as a low-cost magnifier showed promising improvements in reading and visual function for low-vision patients while addressing healthcare waste. Further studies with larger samples are recommended to validate and expand this sustainable approach in visual rehabilitation.</p>\",\"PeriodicalId\":10782,\"journal\":{\"name\":\"Current Eye Research\",\"volume\":\" \",\"pages\":\"719-724\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2025-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Current Eye Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1080/02713683.2025.2478239\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/3/17 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current Eye Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/02713683.2025.2478239","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/3/17 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:评价利用飞秒激光接口制作的低成本光学放大镜用于白内障手术的效果,以减少低视力患者的医疗浪费和经济负担。方法:这项前瞻性研究纳入了来自巴西圣保罗市Misericórdia de s医院低视力科的16例患者。参与者的视力在+0.5到+1.3 logMAR之间,视野收缩在20°以下。Catalys®飞秒激光界面透镜通常在手术后被丢弃,经过消毒并连接到可回收的支架上以创建放大装置。患者接受了30天的使用训练。使用NEI VFQ-25测试视觉功能,使用MNREAD-P测试阅读能力。结果:13例患者(81.25%)完成研究。光学器件的使用导致了MNREAD-P所有参数的显著改善。结论:将飞秒激光界面透镜作为低成本放大镜,可改善低视力患者的阅读和视觉功能,同时解决医疗浪费问题。建议采用更大样本的进一步研究来验证和扩展这种可持续的视觉康复方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Femtosecond Laser Liquid Optics Interface as Low Vision Optical Resource.

Purpose: To assess the efficacy of a low-cost optical magnifier created from the repurposed femtosecond laser interface used in cataract surgery to reduce healthcare waste and financial burden for low-vision patients.

Methods: This prospective study included 16 Brazilian patients from the Low Vision Department of the Irmandade da Santa Casa de Misericórdia de São Paulo. Participants had visual acuity between +0.5 and +1.3 logMAR and visual field constrictions under 20°. The Catalys® femtosecond laser interface lens, usually discarded after surgery, was sterilized and attached to a recyclable support to create a magnifying device. Patients were trained to use it for 30 days. Visual function was assessed with the NEI VFQ-25, and reading performance was measured using the MNREAD-P test.

Results: Thirteen patients (81.25%) completed the study. The use of the optical device led to significant improvements in all MNREAD-P parameters. Reading acuity improved from 0.74 ± 0.19 logMAR (20/110 Snellen) to 0.41 ± 0.22 logMAR (20/50 Snellen) (p < 0.001). Critical print size decreased from 0.85 ± 0.19 logMAR (20/140 Snellen) to 0.56 ± 0.24 logMAR (20/70 Snellen) (p < 0.001). Maximum reading speed increased from 41.4 ± 18.0 words per minute (wpm) to 56.2 ± 25.2 wpm (p < 0.001). NEI VFQ-25 scores improved from 32.7 ± 13.8 to 46.9 ± 15.0 (p < 0.001), with increases observed in all subcategories, particularly in "Reactions to Vision Problems."

Conclusion: Repurposing the femtosecond laser interface lens as a low-cost magnifier showed promising improvements in reading and visual function for low-vision patients while addressing healthcare waste. Further studies with larger samples are recommended to validate and expand this sustainable approach in visual rehabilitation.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Current Eye Research
Current Eye Research 医学-眼科学
CiteScore
4.60
自引率
0.00%
发文量
163
审稿时长
12 months
期刊介绍: The principal aim of Current Eye Research is to provide rapid publication of full papers, short communications and mini-reviews, all high quality. Current Eye Research publishes articles encompassing all the areas of eye research. Subject areas include the following: clinical research, anatomy, physiology, biophysics, biochemistry, pharmacology, developmental biology, microbiology and immunology.
期刊最新文献
Integrated Bioinformatics Analysis of a TF-miRNA-mRNA Regulatory Network in Retinal Vein Occlusion with Metabolic Syndrome and its Association with Clinical Predictors. Correlation Between Refractive Asymmetry and Eye Dominance According to the Sensory and Fixation Method. Isolated Infantile Onset High Myopia: A Case Series with Long-Term Follow-Up. Role of Glutamate Receptor-Related Genes in Myopia Occurrence and Visual Development. The Role of Plasminogen Activator Inhibitor-1 in Uveitis: Findings from Clinical and Experimental Studies.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1