MIP/WS2-AC@Cu-MOF(199)/GCE复合材料:用于实际样品中全氟辛烷的快速和选择性现场电化学检测的可靠溶液。

IF 6.7 1区 化学 Q1 CHEMISTRY, ANALYTICAL Talanta Pub Date : 2025-09-01 Epub Date: 2025-03-16 DOI:10.1016/j.talanta.2025.127958
Liping Zhang , Zhiliang Cheng , Liuwei Zhang , Lanlan Gao , Siqi Li , Zhaoqiang Liu , Lingqiao Wang , Ziyuan Zhou
{"title":"MIP/WS2-AC@Cu-MOF(199)/GCE复合材料:用于实际样品中全氟辛烷的快速和选择性现场电化学检测的可靠溶液。","authors":"Liping Zhang ,&nbsp;Zhiliang Cheng ,&nbsp;Liuwei Zhang ,&nbsp;Lanlan Gao ,&nbsp;Siqi Li ,&nbsp;Zhaoqiang Liu ,&nbsp;Lingqiao Wang ,&nbsp;Ziyuan Zhou","doi":"10.1016/j.talanta.2025.127958","DOIUrl":null,"url":null,"abstract":"<div><div>Perfluorinated compounds (PFCs), recognized as emerging environmental pollutants of global concern due to their persistence and bioaccumulation, have posed serious threats to human health. This underscores the critical need for developing rapid and accurate detection methods for PFCs. In this study, we proposed a novel electrochemical detection approach for perfluorooctanoic (PFO), a representative PFC, employing a WS<sub>2</sub>-AC-modified Cu-MOF(199) electrode integrated with molecularly imprinted polymer (MIP) technology. The MIP, tailored for PFO recognition, was synthesized through electropolymerization of o-phenylenediamine (o-PD) on WS<sub>2</sub>-AC@Cu-MOF(199) composites. Selective adsorption of PFO was enabled by hydrogen bonding interactions between the MIP and target molecules, and achieved effective detection after template elution. The method demonstrated high sensitivity with a broad linear detection range from 34 ng/L to 10.20 μg/L and an ultralow detection limit of 15.15 ng/L. Beyond its sensitivity, this technique exhibited advantages including low fabrication‌ costs, strong anti-interference capabilities, and exceptional selectivity and reproducibility. Notably, this method demonstrated a higher spike recovery compared to GC-MS in PFO detection. These combined features position it as a promising solution for monitoring PFO contamination in aquatic environments.</div></div>","PeriodicalId":435,"journal":{"name":"Talanta","volume":"292 ","pages":"Article 127958"},"PeriodicalIF":6.7000,"publicationDate":"2025-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"MIP/WS2-AC@Cu-MOF(199)/GCE composite: A robust solution for rapid and selective on-site electrochemical detection of perfluorooctane in real samples\",\"authors\":\"Liping Zhang ,&nbsp;Zhiliang Cheng ,&nbsp;Liuwei Zhang ,&nbsp;Lanlan Gao ,&nbsp;Siqi Li ,&nbsp;Zhaoqiang Liu ,&nbsp;Lingqiao Wang ,&nbsp;Ziyuan Zhou\",\"doi\":\"10.1016/j.talanta.2025.127958\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>Perfluorinated compounds (PFCs), recognized as emerging environmental pollutants of global concern due to their persistence and bioaccumulation, have posed serious threats to human health. This underscores the critical need for developing rapid and accurate detection methods for PFCs. In this study, we proposed a novel electrochemical detection approach for perfluorooctanoic (PFO), a representative PFC, employing a WS<sub>2</sub>-AC-modified Cu-MOF(199) electrode integrated with molecularly imprinted polymer (MIP) technology. The MIP, tailored for PFO recognition, was synthesized through electropolymerization of o-phenylenediamine (o-PD) on WS<sub>2</sub>-AC@Cu-MOF(199) composites. Selective adsorption of PFO was enabled by hydrogen bonding interactions between the MIP and target molecules, and achieved effective detection after template elution. The method demonstrated high sensitivity with a broad linear detection range from 34 ng/L to 10.20 μg/L and an ultralow detection limit of 15.15 ng/L. Beyond its sensitivity, this technique exhibited advantages including low fabrication‌ costs, strong anti-interference capabilities, and exceptional selectivity and reproducibility. Notably, this method demonstrated a higher spike recovery compared to GC-MS in PFO detection. These combined features position it as a promising solution for monitoring PFO contamination in aquatic environments.</div></div>\",\"PeriodicalId\":435,\"journal\":{\"name\":\"Talanta\",\"volume\":\"292 \",\"pages\":\"Article 127958\"},\"PeriodicalIF\":6.7000,\"publicationDate\":\"2025-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Talanta\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0039914025004485\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/3/16 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Talanta","FirstCategoryId":"92","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0039914025004485","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/3/16 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

全氟化合物因其持久性和生物蓄积性而被公认为全球关注的新兴环境污染物,对人类健康构成严重威胁。这强调了开发快速准确的全氟化合物检测方法的迫切需要。在这项研究中,我们提出了一种新的电化学检测全氟辛酸(PFO)的方法,该方法采用ws2 - ac修饰的Cu-MOF(199)电极与分子印迹聚合物(MIP)技术集成。通过在WS2-AC@Cu-MOF(199)复合材料上电聚合邻苯二胺(o-PD)合成了专为PFO识别而设计的MIP。通过MIP与靶分子之间的氢键相互作用,实现了PFO的选择性吸附,并在模板洗脱后实现了有效的检测。该法灵敏度高,线性检测范围为34 ~ 10.20 μg/L,超低检出限为15.15 ng/L。除了灵敏度之外,该技术还具有制造成本低、抗干扰能力强、选择性和可重复性强等优点。值得注意的是,与GC-MS相比,该方法在PFO检测中具有更高的峰值恢复。这些综合特点使其成为监测水生环境中PFO污染的有前途的解决方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
MIP/WS2-AC@Cu-MOF(199)/GCE composite: A robust solution for rapid and selective on-site electrochemical detection of perfluorooctane in real samples
Perfluorinated compounds (PFCs), recognized as emerging environmental pollutants of global concern due to their persistence and bioaccumulation, have posed serious threats to human health. This underscores the critical need for developing rapid and accurate detection methods for PFCs. In this study, we proposed a novel electrochemical detection approach for perfluorooctanoic (PFO), a representative PFC, employing a WS2-AC-modified Cu-MOF(199) electrode integrated with molecularly imprinted polymer (MIP) technology. The MIP, tailored for PFO recognition, was synthesized through electropolymerization of o-phenylenediamine (o-PD) on WS2-AC@Cu-MOF(199) composites. Selective adsorption of PFO was enabled by hydrogen bonding interactions between the MIP and target molecules, and achieved effective detection after template elution. The method demonstrated high sensitivity with a broad linear detection range from 34 ng/L to 10.20 μg/L and an ultralow detection limit of 15.15 ng/L. Beyond its sensitivity, this technique exhibited advantages including low fabrication‌ costs, strong anti-interference capabilities, and exceptional selectivity and reproducibility. Notably, this method demonstrated a higher spike recovery compared to GC-MS in PFO detection. These combined features position it as a promising solution for monitoring PFO contamination in aquatic environments.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Talanta
Talanta 化学-分析化学
CiteScore
12.30
自引率
4.90%
发文量
861
审稿时长
29 days
期刊介绍: Talanta provides a forum for the publication of original research papers, short communications, and critical reviews in all branches of pure and applied analytical chemistry. Papers are evaluated based on established guidelines, including the fundamental nature of the study, scientific novelty, substantial improvement or advantage over existing technology or methods, and demonstrated analytical applicability. Original research papers on fundamental studies, and on novel sensor and instrumentation developments, are encouraged. Novel or improved applications in areas such as clinical and biological chemistry, environmental analysis, geochemistry, materials science and engineering, and analytical platforms for omics development are welcome. Analytical performance of methods should be determined, including interference and matrix effects, and methods should be validated by comparison with a standard method, or analysis of a certified reference material. Simple spiking recoveries may not be sufficient. The developed method should especially comprise information on selectivity, sensitivity, detection limits, accuracy, and reliability. However, applying official validation or robustness studies to a routine method or technique does not necessarily constitute novelty. Proper statistical treatment of the data should be provided. Relevant literature should be cited, including related publications by the authors, and authors should discuss how their proposed methodology compares with previously reported methods.
期刊最新文献
Flexible electrospun microcone-array SERS swab for rapid on-site detection of saffron adulteration Lateral flow immunoassay based on electrospun cellulose acetate nanofibrous membrane for C-reactive protein A five-year dive in the realm of crystal engineering with water-soluble vitamins in addressing biopharmaceutical bottlenecks TetR-based biosensors for tetracycline detection: A review of allosteric mechanism, applications, and engineering Analytical validation of a dried blood microsampling method to measure androstenedione, 17α‑hydroxyprogesterone, and 11‑ketotestosterone for congenital adrenal hyperplasia monitoring
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1