利用快速微波开关突破x波段EPR低温探针的灵敏度极限

Uršulė Tarvydytė , Vidmantas Kalendra , Gediminas Usevičius , James O’Sullivan , Adam Brookfield , Alice M. Bowen , Jūras Banys , John J.L. Morton , Mantas Šimėnas
{"title":"利用快速微波开关突破x波段EPR低温探针的灵敏度极限","authors":"Uršulė Tarvydytė ,&nbsp;Vidmantas Kalendra ,&nbsp;Gediminas Usevičius ,&nbsp;James O’Sullivan ,&nbsp;Adam Brookfield ,&nbsp;Alice M. Bowen ,&nbsp;Jūras Banys ,&nbsp;John J.L. Morton ,&nbsp;Mantas Šimėnas","doi":"10.1016/j.jmro.2025.100196","DOIUrl":null,"url":null,"abstract":"<div><div>We present a new design of an X-band EPR cryoprobe based on a fast microwave switch and a cryogenic low-noise microwave amplifier that are placed close to the sample in the same cryostat. The probehead supports high-power (100 W) pulsed EPR experiments and is compatible with standard EPR resonators and samples. In contrast to the directional coupler design of the EPR cryoprobe reported previously, the fast microwave switch fully isolates the microwave amplifier from input thermal noise without microwave power suppression allowing us to approach the sensitivity limit of cryoprobes for pulsed EPR experiments. We benchmark the performance of our cryoprobe setup against a standard commercial EPR instrument revealing a significant sensitivity improvement, which reduces the measurement time by a factor of about <span><math><mrow><mn>250</mn><mo>×</mo></mrow></math></span> at 6 K sample temperature. We also show that the sensitivity of our new X-band cryoprobe design matches that of a standard Q-band setup for double electron–electron resonance experiments.</div></div>","PeriodicalId":365,"journal":{"name":"Journal of Magnetic Resonance Open","volume":"23 ","pages":"Article 100196"},"PeriodicalIF":2.6240,"publicationDate":"2025-04-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Pushing the sensitivity boundaries of X-band EPR cryoprobe using a fast microwave switch\",\"authors\":\"Uršulė Tarvydytė ,&nbsp;Vidmantas Kalendra ,&nbsp;Gediminas Usevičius ,&nbsp;James O’Sullivan ,&nbsp;Adam Brookfield ,&nbsp;Alice M. Bowen ,&nbsp;Jūras Banys ,&nbsp;John J.L. Morton ,&nbsp;Mantas Šimėnas\",\"doi\":\"10.1016/j.jmro.2025.100196\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>We present a new design of an X-band EPR cryoprobe based on a fast microwave switch and a cryogenic low-noise microwave amplifier that are placed close to the sample in the same cryostat. The probehead supports high-power (100 W) pulsed EPR experiments and is compatible with standard EPR resonators and samples. In contrast to the directional coupler design of the EPR cryoprobe reported previously, the fast microwave switch fully isolates the microwave amplifier from input thermal noise without microwave power suppression allowing us to approach the sensitivity limit of cryoprobes for pulsed EPR experiments. We benchmark the performance of our cryoprobe setup against a standard commercial EPR instrument revealing a significant sensitivity improvement, which reduces the measurement time by a factor of about <span><math><mrow><mn>250</mn><mo>×</mo></mrow></math></span> at 6 K sample temperature. We also show that the sensitivity of our new X-band cryoprobe design matches that of a standard Q-band setup for double electron–electron resonance experiments.</div></div>\",\"PeriodicalId\":365,\"journal\":{\"name\":\"Journal of Magnetic Resonance Open\",\"volume\":\"23 \",\"pages\":\"Article 100196\"},\"PeriodicalIF\":2.6240,\"publicationDate\":\"2025-04-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Magnetic Resonance Open\",\"FirstCategoryId\":\"1\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2666441025000123\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Magnetic Resonance Open","FirstCategoryId":"1","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666441025000123","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

我们提出了一种基于快速微波开关和低温低噪声微波放大器的x波段EPR低温探针的新设计,这两个开关和低温低噪声微波放大器放置在同一低温恒温器中靠近样品的位置。探头支持高功率(100 W)脉冲EPR实验,并与标准EPR谐振器和样品兼容。与之前报道的EPR冷冻探针的定向耦合器设计相比,快速微波开关完全隔离了微波放大器与输入热噪声的影响,而不需要微波功率抑制,使我们接近脉冲EPR实验中冷冻探针的灵敏度极限。我们将冷冻探针设置的性能与标准商用EPR仪器进行了基准测试,结果显示灵敏度显着提高,在6 K样品温度下将测量时间减少了约250倍。我们还表明,我们的新x波段冷冻探针设计的灵敏度与双电子-电子共振实验的标准q波段装置相匹配。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Pushing the sensitivity boundaries of X-band EPR cryoprobe using a fast microwave switch
We present a new design of an X-band EPR cryoprobe based on a fast microwave switch and a cryogenic low-noise microwave amplifier that are placed close to the sample in the same cryostat. The probehead supports high-power (100 W) pulsed EPR experiments and is compatible with standard EPR resonators and samples. In contrast to the directional coupler design of the EPR cryoprobe reported previously, the fast microwave switch fully isolates the microwave amplifier from input thermal noise without microwave power suppression allowing us to approach the sensitivity limit of cryoprobes for pulsed EPR experiments. We benchmark the performance of our cryoprobe setup against a standard commercial EPR instrument revealing a significant sensitivity improvement, which reduces the measurement time by a factor of about 250× at 6 K sample temperature. We also show that the sensitivity of our new X-band cryoprobe design matches that of a standard Q-band setup for double electron–electron resonance experiments.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.90
自引率
0.00%
发文量
0
期刊最新文献
Improving a low frequency EPR spectrometer using field-programmable gate array enabled direct digital detection Long-term water migration in hydrated corn stalk pith and hemp stalk by 250 MHz NMR relaxometry and diffusometry Advanced NMR in contemporary China Efficient 15N hyperpolarization of [15N3]metronidazole antibiotic via spin-relayed pulsed SABRE-SHEATH Continuous-flow electron spin resonance microfluidics device with sub-nanoliter sample volume
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1