(o)-[77Br]溴希波兰作为肾小管功能剂的评价

A. van Aswegen , A.J. Van Wyk , J.P. Roodt , H. Pieters , C.P. Herbst , A.C. Otto , M.G. Lötter , F.J. Haasbroek , P.C. Minnaar , P.J. Fourie
{"title":"(o)-[77Br]溴希波兰作为肾小管功能剂的评价","authors":"A. van Aswegen ,&nbsp;A.J. Van Wyk ,&nbsp;J.P. Roodt ,&nbsp;H. Pieters ,&nbsp;C.P. Herbst ,&nbsp;A.C. Otto ,&nbsp;M.G. Lötter ,&nbsp;F.J. Haasbroek ,&nbsp;P.C. Minnaar ,&nbsp;P.J. Fourie","doi":"10.1016/0020-708X(85)90044-4","DOIUrl":null,"url":null,"abstract":"<div><p>(<em>o</em>)-[<sup>77</sup>Br]bromohippuran (BHIP) was developed as renal tubular function agent due to its favourable chemical and physical properties and compared to (<em>o</em>)-[<sup>131</sup>I]iodohippuran (IHIP). Renograms obtained from baboons were compared and absorbed radiation dose calculations performed. Although BHIP showed a delayed kidney uptake and washout pattern, good kidney clearance of the radionuclide was obtained after 30 min. Radiation dose values for BHIP were markedly lower than for IHIP indicating that larger activities of BHIP could be administered to increase counting statistics. BHIP imaging in normal volunteers did however not substantiate the favourable behaviour obtained in the primate.</p></div>","PeriodicalId":22517,"journal":{"name":"The International journal of applied radiation and isotopes","volume":"36 9","pages":"Pages 727-732"},"PeriodicalIF":0.0000,"publicationDate":"1985-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0020-708X(85)90044-4","citationCount":"3","resultStr":"{\"title\":\"Evaluation of (o)-[77Br]bromohippuran as renal tubular function agent\",\"authors\":\"A. van Aswegen ,&nbsp;A.J. Van Wyk ,&nbsp;J.P. Roodt ,&nbsp;H. Pieters ,&nbsp;C.P. Herbst ,&nbsp;A.C. Otto ,&nbsp;M.G. Lötter ,&nbsp;F.J. Haasbroek ,&nbsp;P.C. Minnaar ,&nbsp;P.J. Fourie\",\"doi\":\"10.1016/0020-708X(85)90044-4\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>(<em>o</em>)-[<sup>77</sup>Br]bromohippuran (BHIP) was developed as renal tubular function agent due to its favourable chemical and physical properties and compared to (<em>o</em>)-[<sup>131</sup>I]iodohippuran (IHIP). Renograms obtained from baboons were compared and absorbed radiation dose calculations performed. Although BHIP showed a delayed kidney uptake and washout pattern, good kidney clearance of the radionuclide was obtained after 30 min. Radiation dose values for BHIP were markedly lower than for IHIP indicating that larger activities of BHIP could be administered to increase counting statistics. BHIP imaging in normal volunteers did however not substantiate the favourable behaviour obtained in the primate.</p></div>\",\"PeriodicalId\":22517,\"journal\":{\"name\":\"The International journal of applied radiation and isotopes\",\"volume\":\"36 9\",\"pages\":\"Pages 727-732\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1985-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/0020-708X(85)90044-4\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The International journal of applied radiation and isotopes\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/0020708X85900444\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The International journal of applied radiation and isotopes","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/0020708X85900444","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

(o)-[77Br]溴希波兰(BHIP)与(o)-[131I]碘希波兰(IHIP)相比,具有良好的化学和物理性能,被开发为肾小管功能剂。比较了从狒狒获得的肾图,并计算了吸收的辐射剂量。尽管BHIP表现出延迟的肾脏摄取和冲洗模式,但30分钟后获得了良好的放射性核素肾脏清除率。BHIP的辐射剂量值明显低于IHIP,表明可以给予较大的BHIP活性以增加计数统计。然而,正常志愿者的BHIP成像并没有证实在灵长类动物身上获得的有利行为。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Evaluation of (o)-[77Br]bromohippuran as renal tubular function agent

(o)-[77Br]bromohippuran (BHIP) was developed as renal tubular function agent due to its favourable chemical and physical properties and compared to (o)-[131I]iodohippuran (IHIP). Renograms obtained from baboons were compared and absorbed radiation dose calculations performed. Although BHIP showed a delayed kidney uptake and washout pattern, good kidney clearance of the radionuclide was obtained after 30 min. Radiation dose values for BHIP were markedly lower than for IHIP indicating that larger activities of BHIP could be administered to increase counting statistics. BHIP imaging in normal volunteers did however not substantiate the favourable behaviour obtained in the primate.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Interaction of Polyethylene and Tritium Gas as Monitored by Raman Spectroscopy Editorial Radioiodination and preliminary in vivo investigation of the alkaloid cryptolepine Computer-controlled large scale production of high specific activity [11C]RO 15-1788 for PET studies of benzodiazepine receptors 11C-labelling of indolealkylamine alkaloids and the comparative study of their tissue distributions
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1