失效T-28股骨干残余应力分析。

R D Stroud, S A Brown, J F Shackelford
{"title":"失效T-28股骨干残余应力分析。","authors":"R D Stroud,&nbsp;S A Brown,&nbsp;J F Shackelford","doi":"10.3109/10731198309118790","DOIUrl":null,"url":null,"abstract":"<p><p>Retrieved stainless steel (Type 316L) T-28 femoral stems occasionally exhibit cracks on the medial surface. Since this region is loaded in compression during gait, a simple fatigue fracture explanation is not sufficient to account for these cracks. It has been suggested that they are related to residual stress. It is known that residual stress can contribute a large part of the strain energy near a crack tip. Four failed T-28 femoral stems have been analyzed after surgical retrieval. All of them had multiple visible cracks on the medial side in the region 2-5 cm distal to the calcar collar. All had failed by transverse fractures connecting with a crack on the medial side. These stems have been examined for residual stress by x-ray diffraction methods; significant levels of residual stress were found to be present in the sections tested. Stresses in the transverse direction (medial to lateral) were found to be strongly tensile near the lateral edge and changed to compressive near the medial edge. The area in the center of the sections was found to have nearly zero residual stress.</p>","PeriodicalId":75597,"journal":{"name":"Biomaterials, medical devices, and artificial organs","volume":"11 1","pages":"13-20"},"PeriodicalIF":0.0000,"publicationDate":"1983-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/10731198309118790","citationCount":"0","resultStr":"{\"title\":\"Analysis of residual stress in failed T-28 femoral stems.\",\"authors\":\"R D Stroud,&nbsp;S A Brown,&nbsp;J F Shackelford\",\"doi\":\"10.3109/10731198309118790\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Retrieved stainless steel (Type 316L) T-28 femoral stems occasionally exhibit cracks on the medial surface. Since this region is loaded in compression during gait, a simple fatigue fracture explanation is not sufficient to account for these cracks. It has been suggested that they are related to residual stress. It is known that residual stress can contribute a large part of the strain energy near a crack tip. Four failed T-28 femoral stems have been analyzed after surgical retrieval. All of them had multiple visible cracks on the medial side in the region 2-5 cm distal to the calcar collar. All had failed by transverse fractures connecting with a crack on the medial side. These stems have been examined for residual stress by x-ray diffraction methods; significant levels of residual stress were found to be present in the sections tested. Stresses in the transverse direction (medial to lateral) were found to be strongly tensile near the lateral edge and changed to compressive near the medial edge. The area in the center of the sections was found to have nearly zero residual stress.</p>\",\"PeriodicalId\":75597,\"journal\":{\"name\":\"Biomaterials, medical devices, and artificial organs\",\"volume\":\"11 1\",\"pages\":\"13-20\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1983-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.3109/10731198309118790\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biomaterials, medical devices, and artificial organs\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3109/10731198309118790\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomaterials, medical devices, and artificial organs","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3109/10731198309118790","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

回收的不锈钢(316L型)T-28股骨干偶尔在内侧表面出现裂纹。由于该区域在步态过程中受到压缩载荷,简单的疲劳断裂解释不足以解释这些裂缝。有人认为它们与残余应力有关。众所周知,裂纹尖端附近的残余应力占应变能的很大一部分。我们分析了4例手术切除后失败的T-28股骨干。所有患者均在距踝环远端2-5 cm处内侧有多处可见裂缝。所有的骨折都是横向骨折,并在内侧出现裂缝。用x射线衍射法检测了这些茎的残余应力;显著水平的残余应力被发现存在于测试的部分。横向应力(内侧到外侧)在靠近外侧边缘处表现为强拉伸,在靠近内侧边缘处转变为压缩。截面中心区域的残余应力几乎为零。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Analysis of residual stress in failed T-28 femoral stems.

Retrieved stainless steel (Type 316L) T-28 femoral stems occasionally exhibit cracks on the medial surface. Since this region is loaded in compression during gait, a simple fatigue fracture explanation is not sufficient to account for these cracks. It has been suggested that they are related to residual stress. It is known that residual stress can contribute a large part of the strain energy near a crack tip. Four failed T-28 femoral stems have been analyzed after surgical retrieval. All of them had multiple visible cracks on the medial side in the region 2-5 cm distal to the calcar collar. All had failed by transverse fractures connecting with a crack on the medial side. These stems have been examined for residual stress by x-ray diffraction methods; significant levels of residual stress were found to be present in the sections tested. Stresses in the transverse direction (medial to lateral) were found to be strongly tensile near the lateral edge and changed to compressive near the medial edge. The area in the center of the sections was found to have nearly zero residual stress.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
In vitro C5a generation by synthetic vascular prostheses: implications for graft incorporation in vivo. Particulate aluminum oxide as a bone graft material. Abstracts. Fifth Southern Biomedical Engineering Conference. Shreveport, October 20-21, 1986. Custom-made vaginal balloons for strengthening circumvaginal musculature. Electrical conduction in bone in frequency range 0.4-1.3 GHz.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1