表面置换术后股骨近端应力分布:假体和手术技术的影响。

S D Cook, H B Skinner, A M Weinstein, R J Haddad
{"title":"表面置换术后股骨近端应力分布:假体和手术技术的影响。","authors":"S D Cook,&nbsp;H B Skinner,&nbsp;A M Weinstein,&nbsp;R J Haddad","doi":"10.3109/10731198209118774","DOIUrl":null,"url":null,"abstract":"<p><p>The increasing number of reported femoral neck fractures following surface replacement indicates a potentially serious problem in this procedure. A comparison of the stress levels in the proximal femur before and after hip surface replacement was made using the finite element technique. A proposed surgical bone graft procedure utilizing a strut of cortical bone placed through the femoral head into the neck to help support the surface replacement was also studied as an adjunct for use in avascular necrosis. The findings indicate that stress magnitudes and distributions in the proximal femur are markedly altered after surface replacement when compared to a femur without a prosthesis. Stress levels in the femoral head with surface replacement were found to be significantly lowered suggesting future problems with stress shielding. Lateral neck stresses were found to be equal to or greater than stress levels in the femur without a prosthesis. Stress orientation in the femoral neck is also markedly altered. Surface replacement design and recommended surgical positioning were important variables in determining stress levels. Femoral neck stresses were found to be significantly lowered for all designs of surface replacement when the bone graft modification was utilized. The results of this study explain the major mechanisms of failure of the femoral component. The proposed bone graft modification is demonstrated by the finite element model to decrease the possibility of femoral neck fracture.</p>","PeriodicalId":75597,"journal":{"name":"Biomaterials, medical devices, and artificial organs","volume":"10 2","pages":"85-102"},"PeriodicalIF":0.0000,"publicationDate":"1982-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/10731198209118774","citationCount":"4","resultStr":"{\"title\":\"Stress distribution in the proximal femur after surface replacement: effects of prosthesis and surgical techniques.\",\"authors\":\"S D Cook,&nbsp;H B Skinner,&nbsp;A M Weinstein,&nbsp;R J Haddad\",\"doi\":\"10.3109/10731198209118774\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The increasing number of reported femoral neck fractures following surface replacement indicates a potentially serious problem in this procedure. A comparison of the stress levels in the proximal femur before and after hip surface replacement was made using the finite element technique. A proposed surgical bone graft procedure utilizing a strut of cortical bone placed through the femoral head into the neck to help support the surface replacement was also studied as an adjunct for use in avascular necrosis. The findings indicate that stress magnitudes and distributions in the proximal femur are markedly altered after surface replacement when compared to a femur without a prosthesis. Stress levels in the femoral head with surface replacement were found to be significantly lowered suggesting future problems with stress shielding. Lateral neck stresses were found to be equal to or greater than stress levels in the femur without a prosthesis. Stress orientation in the femoral neck is also markedly altered. Surface replacement design and recommended surgical positioning were important variables in determining stress levels. Femoral neck stresses were found to be significantly lowered for all designs of surface replacement when the bone graft modification was utilized. The results of this study explain the major mechanisms of failure of the femoral component. The proposed bone graft modification is demonstrated by the finite element model to decrease the possibility of femoral neck fracture.</p>\",\"PeriodicalId\":75597,\"journal\":{\"name\":\"Biomaterials, medical devices, and artificial organs\",\"volume\":\"10 2\",\"pages\":\"85-102\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1982-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.3109/10731198209118774\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biomaterials, medical devices, and artificial organs\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3109/10731198209118774\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomaterials, medical devices, and artificial organs","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3109/10731198209118774","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

表面置换术后股骨颈骨折的报道越来越多,这表明该手术存在潜在的严重问题。采用有限元技术比较髋关节置换术前后股骨近端应力水平。一种拟议的外科骨移植手术也被研究,该手术利用皮质骨支柱通过股骨头放置到颈部,以帮助支持表面置换,作为用于缺血性坏死的辅助手段。研究结果表明,与未植入假体的股骨相比,表面置换术后股骨近端应力大小和分布明显改变。发现股骨头表面置换术后应力水平显著降低,提示将来应力屏蔽的问题。发现侧颈应力等于或大于无假体股骨的应力水平。股骨颈的应力方向也明显改变。表面置换设计和推荐的手术定位是决定应力水平的重要变量。采用骨移植物改良后,所有表面置换设计的股骨颈应力均显著降低。本研究的结果解释了股骨假体失效的主要机制。通过有限元模型验证了所提出的骨移植改良可以降低股骨颈骨折的可能性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Stress distribution in the proximal femur after surface replacement: effects of prosthesis and surgical techniques.

The increasing number of reported femoral neck fractures following surface replacement indicates a potentially serious problem in this procedure. A comparison of the stress levels in the proximal femur before and after hip surface replacement was made using the finite element technique. A proposed surgical bone graft procedure utilizing a strut of cortical bone placed through the femoral head into the neck to help support the surface replacement was also studied as an adjunct for use in avascular necrosis. The findings indicate that stress magnitudes and distributions in the proximal femur are markedly altered after surface replacement when compared to a femur without a prosthesis. Stress levels in the femoral head with surface replacement were found to be significantly lowered suggesting future problems with stress shielding. Lateral neck stresses were found to be equal to or greater than stress levels in the femur without a prosthesis. Stress orientation in the femoral neck is also markedly altered. Surface replacement design and recommended surgical positioning were important variables in determining stress levels. Femoral neck stresses were found to be significantly lowered for all designs of surface replacement when the bone graft modification was utilized. The results of this study explain the major mechanisms of failure of the femoral component. The proposed bone graft modification is demonstrated by the finite element model to decrease the possibility of femoral neck fracture.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
In vitro C5a generation by synthetic vascular prostheses: implications for graft incorporation in vivo. Particulate aluminum oxide as a bone graft material. Abstracts. Fifth Southern Biomedical Engineering Conference. Shreveport, October 20-21, 1986. Custom-made vaginal balloons for strengthening circumvaginal musculature. Electrical conduction in bone in frequency range 0.4-1.3 GHz.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1