T W Starr
{"title":"对截肢者残肢进行体积分析的计算机化装置。","authors":"T W Starr","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Prosthetics Research Study has developed a computerized automated system for the volumetric analysis of the residual limbs of amputees. Basically, this system utilizes the same principles as does normal, clinical fluid displacement volumetric analysis, with the addition of the following--if an object is suspended in a vertical cylinder into which water is being injected at a constant rate, then the rate of rise of the water will vary proportionally, at any point, with the cross-sectional area of the object. In this system, water is pumped into a Plexiglas cylinder of appropriate size so as to immerse a residual limb within a time frame of under ten seconds while a microcomputer records the water depth as a function of time. The rate of water depth rise is recorded for 256 levels during a measurement. These results are then analyzed comparatively, on a level-for-level basis, with similar rates generated with fluid pumped into the empty cylinder, thus generating 256 discrete cross-sectional-area parameters. These are then processed (in groups of eight) into 32 actual cross sections and displayed, graphed, or stored for purposes of comparison. Possible clinical application for this kind of device includes measurement of edema and other extremity volume changes with time, and measurement of muscle activity related to axial movements of muscle bulk.</p>","PeriodicalId":75645,"journal":{"name":"Bulletin of prosthetics research","volume":"10-33 ","pages":"98-102"},"PeriodicalIF":0.0000,"publicationDate":"1980-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A computerized device for the volumetric analysis of the residual limbs of amputees.\",\"authors\":\"T W Starr\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Prosthetics Research Study has developed a computerized automated system for the volumetric analysis of the residual limbs of amputees. Basically, this system utilizes the same principles as does normal, clinical fluid displacement volumetric analysis, with the addition of the following--if an object is suspended in a vertical cylinder into which water is being injected at a constant rate, then the rate of rise of the water will vary proportionally, at any point, with the cross-sectional area of the object. In this system, water is pumped into a Plexiglas cylinder of appropriate size so as to immerse a residual limb within a time frame of under ten seconds while a microcomputer records the water depth as a function of time. The rate of water depth rise is recorded for 256 levels during a measurement. These results are then analyzed comparatively, on a level-for-level basis, with similar rates generated with fluid pumped into the empty cylinder, thus generating 256 discrete cross-sectional-area parameters. These are then processed (in groups of eight) into 32 actual cross sections and displayed, graphed, or stored for purposes of comparison. Possible clinical application for this kind of device includes measurement of edema and other extremity volume changes with time, and measurement of muscle activity related to axial movements of muscle bulk.</p>\",\"PeriodicalId\":75645,\"journal\":{\"name\":\"Bulletin of prosthetics research\",\"volume\":\"10-33 \",\"pages\":\"98-102\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1980-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Bulletin of prosthetics research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bulletin of prosthetics research","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

假肢研究研究已经开发了一种计算机自动化系统,用于截肢者残肢的体积分析。基本上,该系统利用了与常规临床流体位移体积分析相同的原理,并增加了以下内容:如果一个物体悬浮在一个垂直的圆柱体中,并以恒定的速度注入水,那么水的上升速度将在任何一点与物体的横截面积成比例地变化。在这个系统中,水被泵入一个适当大小的有机玻璃圆柱体中,以便在不到10秒的时间内浸入残肢,同时微型计算机记录水深作为时间的函数。在一次测量中,记录了256个水位的水深上升速率。然后对这些结果进行逐级比较分析,将流体泵入空筒产生的速率相似,从而产生256个离散的横截面面积参数。然后将它们(每8组)处理成32个实际的横截面,并显示、绘制图形或存储以供比较。该装置可能的临床应用包括测量水肿和其他肢体体积随时间的变化,以及测量与肌肉体积轴向运动相关的肌肉活动。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A computerized device for the volumetric analysis of the residual limbs of amputees.

Prosthetics Research Study has developed a computerized automated system for the volumetric analysis of the residual limbs of amputees. Basically, this system utilizes the same principles as does normal, clinical fluid displacement volumetric analysis, with the addition of the following--if an object is suspended in a vertical cylinder into which water is being injected at a constant rate, then the rate of rise of the water will vary proportionally, at any point, with the cross-sectional area of the object. In this system, water is pumped into a Plexiglas cylinder of appropriate size so as to immerse a residual limb within a time frame of under ten seconds while a microcomputer records the water depth as a function of time. The rate of water depth rise is recorded for 256 levels during a measurement. These results are then analyzed comparatively, on a level-for-level basis, with similar rates generated with fluid pumped into the empty cylinder, thus generating 256 discrete cross-sectional-area parameters. These are then processed (in groups of eight) into 32 actual cross sections and displayed, graphed, or stored for purposes of comparison. Possible clinical application for this kind of device includes measurement of edema and other extremity volume changes with time, and measurement of muscle activity related to axial movements of muscle bulk.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A simulator for objectively evaluating prospective drivers of the Scott van. A new communications technique for the nonvocal person, using the Apple II Computer. Microprocessor-based communications system for the non-verbal person with serious motor handicaps: a preliminary report. The practical use of microcomputers in rehabilitation. A circulation study: "The Bulletin" uses simple techniques to sample reader preferences and to adjust institutional shipments to changing needs.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1