从血淋巴到体内:在质量有限的环境样品中,具有单独锁腔的1毫米微升流量探针的潜力

Monica Bastawrous , Daniel Lane , Ronald Soong , Maryam Tabatabaei Anaraki , Daniel Schmidig , Thomas Frei , Peter De Castro , Stephan Graf , Till Kuehn , Rainer Kümmerle , Falko Busse , Hermann Heumann , Holger Boenisch , Marcel Gundy , Andre J. Simpson
{"title":"从血淋巴到体内:在质量有限的环境样品中,具有单独锁腔的1毫米微升流量探针的潜力","authors":"Monica Bastawrous ,&nbsp;Daniel Lane ,&nbsp;Ronald Soong ,&nbsp;Maryam Tabatabaei Anaraki ,&nbsp;Daniel Schmidig ,&nbsp;Thomas Frei ,&nbsp;Peter De Castro ,&nbsp;Stephan Graf ,&nbsp;Till Kuehn ,&nbsp;Rainer Kümmerle ,&nbsp;Falko Busse ,&nbsp;Hermann Heumann ,&nbsp;Holger Boenisch ,&nbsp;Marcel Gundy ,&nbsp;Andre J. Simpson","doi":"10.1016/j.jmro.2022.100079","DOIUrl":null,"url":null,"abstract":"<div><p>Metabolomics is one of the leading approaches for understanding the toxic-mode-of-action of environmental contaminants. Nuclear Magnetic Resonance (NMR) spectroscopy has been commonly used in metabolomic studies; however, its main drawback is its relatively low sensitivity, making it challenging to study mass limited but environmentally crucial samples. In this work a 1 mm microlitre probe modified with a separate lock chamber to address this challenge, provided substantial improvements in mass sensitivity relative to conventional 5 mm NMR probes. The 1 mm probe is used to analyze various components of the model organism <em>Daphnia magna</em>, including hemolymph, parthenogenetic eggs, dormant eggs, and neonates. A μL volume flow system is designed for the 1 mm probe to perform an <em>in-vivo</em> exposure of neonates to high salt concentrations. The metabolic investigation of these samples was only achieved due to the minimum sample requirements and high salt tolerance of the probe, demonstrating that the 1 mm microlitre probe modified with a separate lock chamber holds significant potential for future metabolomic studies of mass limited samples.</p></div>","PeriodicalId":365,"journal":{"name":"Journal of Magnetic Resonance Open","volume":null,"pages":null},"PeriodicalIF":2.6240,"publicationDate":"2022-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"From hemolymph to in-vivo: The potential of a 1 mm microlitre flow probe with separate lock chamber for NMR metabolomics in mass limited environmental samples\",\"authors\":\"Monica Bastawrous ,&nbsp;Daniel Lane ,&nbsp;Ronald Soong ,&nbsp;Maryam Tabatabaei Anaraki ,&nbsp;Daniel Schmidig ,&nbsp;Thomas Frei ,&nbsp;Peter De Castro ,&nbsp;Stephan Graf ,&nbsp;Till Kuehn ,&nbsp;Rainer Kümmerle ,&nbsp;Falko Busse ,&nbsp;Hermann Heumann ,&nbsp;Holger Boenisch ,&nbsp;Marcel Gundy ,&nbsp;Andre J. Simpson\",\"doi\":\"10.1016/j.jmro.2022.100079\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Metabolomics is one of the leading approaches for understanding the toxic-mode-of-action of environmental contaminants. Nuclear Magnetic Resonance (NMR) spectroscopy has been commonly used in metabolomic studies; however, its main drawback is its relatively low sensitivity, making it challenging to study mass limited but environmentally crucial samples. In this work a 1 mm microlitre probe modified with a separate lock chamber to address this challenge, provided substantial improvements in mass sensitivity relative to conventional 5 mm NMR probes. The 1 mm probe is used to analyze various components of the model organism <em>Daphnia magna</em>, including hemolymph, parthenogenetic eggs, dormant eggs, and neonates. A μL volume flow system is designed for the 1 mm probe to perform an <em>in-vivo</em> exposure of neonates to high salt concentrations. The metabolic investigation of these samples was only achieved due to the minimum sample requirements and high salt tolerance of the probe, demonstrating that the 1 mm microlitre probe modified with a separate lock chamber holds significant potential for future metabolomic studies of mass limited samples.</p></div>\",\"PeriodicalId\":365,\"journal\":{\"name\":\"Journal of Magnetic Resonance Open\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.6240,\"publicationDate\":\"2022-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Magnetic Resonance Open\",\"FirstCategoryId\":\"1\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2666441022000498\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Magnetic Resonance Open","FirstCategoryId":"1","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666441022000498","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

代谢组学是了解环境污染物毒性作用模式的主要方法之一。核磁共振(NMR)光谱已广泛用于代谢组学研究;然而,它的主要缺点是相对较低的灵敏度,这使得研究质量有限但对环境至关重要的样品具有挑战性。在这项工作中,一个1毫米微升探针经过单独锁腔的修改,以解决这一挑战,相对于传统的5毫米核磁共振探针,质量灵敏度有了实质性的提高。1毫米探针用于分析模式生物大水蚤的各种成分,包括血淋巴、孤雌卵、休眠卵和新生卵。设计了一种μL容积流系统,用于1mm探针对新生儿进行体内高盐暴露。这些样品的代谢研究是由于探针的最低样品要求和高耐盐性而实现的,这表明经过单独锁腔修饰的1毫米微升探针在未来质量有限样品的代谢组学研究中具有重要潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
From hemolymph to in-vivo: The potential of a 1 mm microlitre flow probe with separate lock chamber for NMR metabolomics in mass limited environmental samples

Metabolomics is one of the leading approaches for understanding the toxic-mode-of-action of environmental contaminants. Nuclear Magnetic Resonance (NMR) spectroscopy has been commonly used in metabolomic studies; however, its main drawback is its relatively low sensitivity, making it challenging to study mass limited but environmentally crucial samples. In this work a 1 mm microlitre probe modified with a separate lock chamber to address this challenge, provided substantial improvements in mass sensitivity relative to conventional 5 mm NMR probes. The 1 mm probe is used to analyze various components of the model organism Daphnia magna, including hemolymph, parthenogenetic eggs, dormant eggs, and neonates. A μL volume flow system is designed for the 1 mm probe to perform an in-vivo exposure of neonates to high salt concentrations. The metabolic investigation of these samples was only achieved due to the minimum sample requirements and high salt tolerance of the probe, demonstrating that the 1 mm microlitre probe modified with a separate lock chamber holds significant potential for future metabolomic studies of mass limited samples.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.90
自引率
0.00%
发文量
0
期刊最新文献
Creating high, portable proton polarization with photo-excited triplet DNP Understanding magnetic fields, for NMR/MRI Fast quantitative MRI: Spiral Acquisition Matching-Based Algorithm (SAMBA) for Robust T1 and T2 Mapping Automated hyperpolarized 129Xe gas generator for nuclear magnetic resonance spectroscopy and imaging applications A comprehensive solid-state NMR and theoretical modeling study to reveal the structural evolution of layered yttrium hydroxide upon calcination
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1