{"title":"扇形扫描和线阵超声探头在腹腔镜手术中的临床应用经验。","authors":"T G John,&nbsp;O J Garden","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Laparoscopic ultrasonography combines the advantages of diagnostic laparoscopy and intraoperative contact ultrasonography. The early prototypes were based on the linear array intraoperative ultrasound transducer, which provided the hepatobiliary surgeon with detailed information on the hepatic and pancreatic tumour in addition to its relationship with the associated vasculature. The laparoscopic linear array probes provide similar information in patients submitted to diagnostic laparoscopy and provide the surgeon with rectilinear images that are easy to interpret. Laparoscopic sector scanning probes are now available and have the advantage of requiring only a small area of contact to produce a pie-shaped scan of the area of interest. Such images may be more difficult to orientate, but end viewing probes enable rapid changes in image direction when rotated and are probably the probe of choice in the detection of choledocholithiasis. At the present time, the laparoscopic ultrasonographer may have need of both probes to enable adequate evaluation of intraabdominal pathology. Technological advances will almost certainly provide more versatile ultrasound systems that will confirm the place of laparoscopic ultrasonography as a valuable investigative tool during laparoscopic procedures.</p>","PeriodicalId":79337,"journal":{"name":"Endoscopic surgery and allied technologies","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1994-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Clinical experience with sector scan and linear array ultrasound probes in laparoscopic surgery.\",\"authors\":\"T G John,&nbsp;O J Garden\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Laparoscopic ultrasonography combines the advantages of diagnostic laparoscopy and intraoperative contact ultrasonography. The early prototypes were based on the linear array intraoperative ultrasound transducer, which provided the hepatobiliary surgeon with detailed information on the hepatic and pancreatic tumour in addition to its relationship with the associated vasculature. The laparoscopic linear array probes provide similar information in patients submitted to diagnostic laparoscopy and provide the surgeon with rectilinear images that are easy to interpret. Laparoscopic sector scanning probes are now available and have the advantage of requiring only a small area of contact to produce a pie-shaped scan of the area of interest. Such images may be more difficult to orientate, but end viewing probes enable rapid changes in image direction when rotated and are probably the probe of choice in the detection of choledocholithiasis. At the present time, the laparoscopic ultrasonographer may have need of both probes to enable adequate evaluation of intraabdominal pathology. Technological advances will almost certainly provide more versatile ultrasound systems that will confirm the place of laparoscopic ultrasonography as a valuable investigative tool during laparoscopic procedures.</p>\",\"PeriodicalId\":79337,\"journal\":{\"name\":\"Endoscopic surgery and allied technologies\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1994-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Endoscopic surgery and allied technologies\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Endoscopic surgery and allied technologies","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

腹腔镜超声检查结合了诊断性腹腔镜检查和术中接触超声检查的优点。早期的原型是基于线性阵列术中超声换能器,它为肝胆外科医生提供了肝脏和胰腺肿瘤的详细信息,以及它与相关脉管系统的关系。腹腔镜线性阵列探头在接受腹腔镜诊断的患者中提供类似的信息,并为外科医生提供易于解释的直线图像。腹腔镜扇形扫描探头现在是可用的,其优点是只需要一个小的接触区域来产生感兴趣的区域的饼状扫描。这样的图像可能更难以定位,但末端观察探头在旋转时可以快速改变图像方向,可能是检测胆总管结石的首选探头。目前,腹腔镜超声医师可能需要这两种探头来充分评估腹腔内病理。技术进步几乎肯定会提供更多功能的超声系统,这将确认腹腔镜超声检查作为腹腔镜手术中有价值的检查工具的地位。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Clinical experience with sector scan and linear array ultrasound probes in laparoscopic surgery.

Laparoscopic ultrasonography combines the advantages of diagnostic laparoscopy and intraoperative contact ultrasonography. The early prototypes were based on the linear array intraoperative ultrasound transducer, which provided the hepatobiliary surgeon with detailed information on the hepatic and pancreatic tumour in addition to its relationship with the associated vasculature. The laparoscopic linear array probes provide similar information in patients submitted to diagnostic laparoscopy and provide the surgeon with rectilinear images that are easy to interpret. Laparoscopic sector scanning probes are now available and have the advantage of requiring only a small area of contact to produce a pie-shaped scan of the area of interest. Such images may be more difficult to orientate, but end viewing probes enable rapid changes in image direction when rotated and are probably the probe of choice in the detection of choledocholithiasis. At the present time, the laparoscopic ultrasonographer may have need of both probes to enable adequate evaluation of intraabdominal pathology. Technological advances will almost certainly provide more versatile ultrasound systems that will confirm the place of laparoscopic ultrasonography as a valuable investigative tool during laparoscopic procedures.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Anaesthesia for laparoscopic cholecystectomy in high-risk patients. Preoperative morbidity and anaesthesia-related negative events in patients undergoing conventional or laparoscopic cholecystectomy. Quantitative standardised analysis of advanced laparoscopic surgical procedures. Respiratory changes during laparoscopic operations. Variance of cardiorespiratory parameters during gynaecological surgery with CO2-pneumoperitoneum.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1