甘露醇和一些相关立体异构体冷冻溶液的热力学分析:加热过程中膨胀的证据和冻干过程中小瓶破裂的相关性。

N A Williams, J Guglielmo
{"title":"甘露醇和一些相关立体异构体冷冻溶液的热力学分析:加热过程中膨胀的证据和冻干过程中小瓶破裂的相关性。","authors":"N A Williams,&nbsp;J Guglielmo","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The mechanical properties of frozen mannitol, L-iditol, dulcitol, and sorbitol solutions were measured as a function of temperature during warming (after freezing) using a thermal mechanical analyzer (TMA). The mannitol sample first underwent a contractive phase starting at 30 degrees C and ending at -25 degrees C. This was followed by an initially rapid, then less rapid expansive phase which continued until melting occurred. These events provide direct evidence that mannitol solutions undergo an expansion during warming after \"fast\" freezing and also corroborate the vial breakage observed when mannitol solutions are frozen and thawed or freeze-dried in glass vials. Of the other stereoisomers studied, only dulcitol had an expansive phase although at a slower rate than mannitol. Its solution was found to cause vial breakage also but only at fill volumes higher than mannitol fill volumes. TMA is a useful technique for studying dimensional changes in the frozen state, with important implications for solving vial breakage problems in freeze-drying.</p>","PeriodicalId":16667,"journal":{"name":"Journal of parenteral science and technology : a publication of the Parenteral Drug Association","volume":"47 3","pages":"119-23"},"PeriodicalIF":0.0000,"publicationDate":"1993-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Thermal mechanical analysis of frozen solutions of mannitol and some related stereoisomers: evidence of expansion during warming and correlation with vial breakage during lyophilization.\",\"authors\":\"N A Williams,&nbsp;J Guglielmo\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The mechanical properties of frozen mannitol, L-iditol, dulcitol, and sorbitol solutions were measured as a function of temperature during warming (after freezing) using a thermal mechanical analyzer (TMA). The mannitol sample first underwent a contractive phase starting at 30 degrees C and ending at -25 degrees C. This was followed by an initially rapid, then less rapid expansive phase which continued until melting occurred. These events provide direct evidence that mannitol solutions undergo an expansion during warming after \\\"fast\\\" freezing and also corroborate the vial breakage observed when mannitol solutions are frozen and thawed or freeze-dried in glass vials. Of the other stereoisomers studied, only dulcitol had an expansive phase although at a slower rate than mannitol. Its solution was found to cause vial breakage also but only at fill volumes higher than mannitol fill volumes. TMA is a useful technique for studying dimensional changes in the frozen state, with important implications for solving vial breakage problems in freeze-drying.</p>\",\"PeriodicalId\":16667,\"journal\":{\"name\":\"Journal of parenteral science and technology : a publication of the Parenteral Drug Association\",\"volume\":\"47 3\",\"pages\":\"119-23\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1993-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of parenteral science and technology : a publication of the Parenteral Drug Association\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of parenteral science and technology : a publication of the Parenteral Drug Association","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

使用热力学分析仪(TMA)测量了冷冻甘露醇、l -二糖醇、dulcitol和山梨糖醇溶液在加热(冷冻后)期间的力学性能与温度的关系。甘露醇样品首先经历了一个从30℃开始到-25℃结束的收缩阶段,随后是一个最初快速的膨胀阶段,然后持续到融化。这些事件提供了直接证据,证明甘露醇溶液在“快速”冷冻后的升温过程中会发生膨胀,也证实了甘露醇溶液在玻璃小瓶中冷冻、解冻或冷冻干燥时所观察到的小瓶破裂。在研究的其他立体异构体中,只有dulcitol有膨胀相,尽管速度比甘露醇慢。它的溶液也被发现导致瓶子破裂,但只有在填充体积高于甘露醇填充体积。TMA是研究冷冻状态下尺寸变化的一种有用的技术,对解决冷冻干燥中小瓶破裂问题具有重要意义。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Thermal mechanical analysis of frozen solutions of mannitol and some related stereoisomers: evidence of expansion during warming and correlation with vial breakage during lyophilization.

The mechanical properties of frozen mannitol, L-iditol, dulcitol, and sorbitol solutions were measured as a function of temperature during warming (after freezing) using a thermal mechanical analyzer (TMA). The mannitol sample first underwent a contractive phase starting at 30 degrees C and ending at -25 degrees C. This was followed by an initially rapid, then less rapid expansive phase which continued until melting occurred. These events provide direct evidence that mannitol solutions undergo an expansion during warming after "fast" freezing and also corroborate the vial breakage observed when mannitol solutions are frozen and thawed or freeze-dried in glass vials. Of the other stereoisomers studied, only dulcitol had an expansive phase although at a slower rate than mannitol. Its solution was found to cause vial breakage also but only at fill volumes higher than mannitol fill volumes. TMA is a useful technique for studying dimensional changes in the frozen state, with important implications for solving vial breakage problems in freeze-drying.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Evaluating out-of-specification laboratory results. Simplifying and improving process validation. Depyrogenation of pharmaceutical solutions using submicron and ultrafilters. USP perspectives on particle contamination of injectable products. Moisture measurement: a new method for monitoring freeze-drying cycles.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1