材料应变存在下的扩散测量

Timothy G. Reese, Van J. Wedeen, Robert M. Weisskoff
{"title":"材料应变存在下的扩散测量","authors":"Timothy G. Reese,&nbsp;Van J. Wedeen,&nbsp;Robert M. Weisskoff","doi":"10.1006/jmrb.1996.0139","DOIUrl":null,"url":null,"abstract":"<div><p>Material strain during the course of diffusion encoding by MRI will in general change the observed diffusional signal losses. These changes will occur even when the material returns cyclically to its initial location during the diffusion-evolution period. This effect derives from the modification of the local spatial modulation k of spin phase within a sample by a material deformation \\font\\serif=cmss10 at 10pt[formula]as k →[formula]k, resulting in an observed diffusion tensor[formula]where[formula]is the material stretch tensor. For example, when a material is compressed during pulsed-gradient diffusion encoding, the compression acts to increase the attenuation due to diffusion just as if a larger gradient were used. By using a simple gelatin phantom, the existence of this effect is demonstrated, and an effective method for its correction based on an MRI mapping of the material strain is presented. This correction is particularly relevant for inferring myofiber structure in the beating<em>in vivo</em>human heart, since the measurement of[formula]is perturbed by the deformation of myocardium during the heart's contraction.</p></div>","PeriodicalId":16130,"journal":{"name":"Journal of Magnetic Resonance, Series B","volume":"112 3","pages":"Pages 253-258"},"PeriodicalIF":0.0000,"publicationDate":"1996-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1006/jmrb.1996.0139","citationCount":"73","resultStr":"{\"title\":\"Measuring Diffusion in the Presence of Material Strain\",\"authors\":\"Timothy G. Reese,&nbsp;Van J. Wedeen,&nbsp;Robert M. Weisskoff\",\"doi\":\"10.1006/jmrb.1996.0139\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Material strain during the course of diffusion encoding by MRI will in general change the observed diffusional signal losses. These changes will occur even when the material returns cyclically to its initial location during the diffusion-evolution period. This effect derives from the modification of the local spatial modulation k of spin phase within a sample by a material deformation \\\\font\\\\serif=cmss10 at 10pt[formula]as k →[formula]k, resulting in an observed diffusion tensor[formula]where[formula]is the material stretch tensor. For example, when a material is compressed during pulsed-gradient diffusion encoding, the compression acts to increase the attenuation due to diffusion just as if a larger gradient were used. By using a simple gelatin phantom, the existence of this effect is demonstrated, and an effective method for its correction based on an MRI mapping of the material strain is presented. This correction is particularly relevant for inferring myofiber structure in the beating<em>in vivo</em>human heart, since the measurement of[formula]is perturbed by the deformation of myocardium during the heart's contraction.</p></div>\",\"PeriodicalId\":16130,\"journal\":{\"name\":\"Journal of Magnetic Resonance, Series B\",\"volume\":\"112 3\",\"pages\":\"Pages 253-258\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1996-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1006/jmrb.1996.0139\",\"citationCount\":\"73\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Magnetic Resonance, Series B\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1064186696901399\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Magnetic Resonance, Series B","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1064186696901399","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 73

摘要

MRI扩散编码过程中的材料应变通常会改变观测到的扩散信号损耗。即使材料在扩散演化期间周期性地返回到其初始位置,这些变化也会发生。这种效应来源于材料变形\font\serif=cmss10在10pt[公式]处将样品内自旋相的局部空间调制k修改为k→[公式]k,从而得到观测到的扩散张量[公式],其中[公式]为材料拉伸张量。例如,当在脉冲梯度扩散编码期间压缩材料时,压缩的作用是增加扩散引起的衰减,就像使用了更大的梯度一样。通过使用一个简单的明胶幻影,证明了这种效应的存在,并提出了一种基于材料应变的MRI映射的有效校正方法。由于[式]的测量会受到心脏收缩过程中心肌变形的干扰,因此这一修正对于推断人体内心脏搏动中的肌纤维结构尤为重要。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Measuring Diffusion in the Presence of Material Strain

Material strain during the course of diffusion encoding by MRI will in general change the observed diffusional signal losses. These changes will occur even when the material returns cyclically to its initial location during the diffusion-evolution period. This effect derives from the modification of the local spatial modulation k of spin phase within a sample by a material deformation \font\serif=cmss10 at 10pt[formula]as k →[formula]k, resulting in an observed diffusion tensor[formula]where[formula]is the material stretch tensor. For example, when a material is compressed during pulsed-gradient diffusion encoding, the compression acts to increase the attenuation due to diffusion just as if a larger gradient were used. By using a simple gelatin phantom, the existence of this effect is demonstrated, and an effective method for its correction based on an MRI mapping of the material strain is presented. This correction is particularly relevant for inferring myofiber structure in the beatingin vivohuman heart, since the measurement of[formula]is perturbed by the deformation of myocardium during the heart's contraction.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A Three-Dimensional NMR Imaging Scheme Utilizing Doubly Resonant Gradient Coils HCN, A Triple-Resonance NMR Technique for Selective Observation of Histidine and Tryptophan Side Chains in13C/15N-Labeled Proteins Extracting Quantitative Information from Two- and Three-Dimensional NOE Spectra Measured with Short Recycle Delays In VivoImaging of Nitroxide-Free-Radical Clearance in the Rat, Using Radiofrequency Longitudinally Detected ESR Imaging NMR Pulse Schemes for the Sequential Assignment of Arginine Side-Chain HϵProtons
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1