{"title":"动脉导管未闭线圈栓塞后溶血。","authors":"D Shim, D S Wechsler, T R Lloyd, R H Beekman","doi":"10.1002/(SICI)1097-0304(199611)39:3<287::AID-CCD17>3.0.CO;2-C","DOIUrl":null,"url":null,"abstract":"<p><p>We describe the development of hemolysis from moderate residual shunting across a patent ductus arteriosus following coil embolization. The fall in hemoglobin levels from 11.6 to 6.0 gm/dl necessitated a second coil procedure which resulted in complete closure of the residual shunting and resolution of hemolysis. Therefore, appearance of anemia following coil embolization of patent ductus arteriosus should be monitored closely; however, repeat coil embolization with elimination of residual shunt will lead to prompt recovery of normal hemoglobin levels.</p>","PeriodicalId":9664,"journal":{"name":"Catheterization and cardiovascular diagnosis","volume":"39 3","pages":"287-90"},"PeriodicalIF":0.0000,"publicationDate":"1996-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"59","resultStr":"{\"title\":\"Hemolysis following coil embolization of a patent ductus arteriosus.\",\"authors\":\"D Shim, D S Wechsler, T R Lloyd, R H Beekman\",\"doi\":\"10.1002/(SICI)1097-0304(199611)39:3<287::AID-CCD17>3.0.CO;2-C\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>We describe the development of hemolysis from moderate residual shunting across a patent ductus arteriosus following coil embolization. The fall in hemoglobin levels from 11.6 to 6.0 gm/dl necessitated a second coil procedure which resulted in complete closure of the residual shunting and resolution of hemolysis. Therefore, appearance of anemia following coil embolization of patent ductus arteriosus should be monitored closely; however, repeat coil embolization with elimination of residual shunt will lead to prompt recovery of normal hemoglobin levels.</p>\",\"PeriodicalId\":9664,\"journal\":{\"name\":\"Catheterization and cardiovascular diagnosis\",\"volume\":\"39 3\",\"pages\":\"287-90\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1996-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"59\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Catheterization and cardiovascular diagnosis\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1002/(SICI)1097-0304(199611)39:3<287::AID-CCD17>3.0.CO;2-C\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Catheterization and cardiovascular diagnosis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/(SICI)1097-0304(199611)39:3<287::AID-CCD17>3.0.CO;2-C","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Hemolysis following coil embolization of a patent ductus arteriosus.
We describe the development of hemolysis from moderate residual shunting across a patent ductus arteriosus following coil embolization. The fall in hemoglobin levels from 11.6 to 6.0 gm/dl necessitated a second coil procedure which resulted in complete closure of the residual shunting and resolution of hemolysis. Therefore, appearance of anemia following coil embolization of patent ductus arteriosus should be monitored closely; however, repeat coil embolization with elimination of residual shunt will lead to prompt recovery of normal hemoglobin levels.