10、20和40水平电子束计算机断层扫描对冠状动脉钙化的比较。

American journal of cardiac imaging Pub Date : 1996-10-01
J P Shields, C H Mielke, P Watson, F Viren
{"title":"10、20和40水平电子束计算机断层扫描对冠状动脉钙化的比较。","authors":"J P Shields,&nbsp;C H Mielke,&nbsp;P Watson,&nbsp;F Viren","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>There are increasing data to support the use of the electron beam computed tomography (EBCT) scanner for early detection of coronary artery disease (CAD). A negative scan essentially rules out significant disease. How many EBCT 3 mm contiguous slices are needed to cover the coronary circulation? To answer this question, 104 consecutive patients referred for EBCT scan for evaluation of coronary artery calcium (CAC) were asked to participate. The sensitivity and negative predictive value (NPV) of calcium scores for the first 10 slices and first 20 slices, the second 20 slices, and the total scan were recorded. Scores greater than one were regarded as positive. The number of levels required to cover the entire heart was also recorded. Fifty-nine patients (56.7%) had a positive calcium score for the total scan. Of these, 53 were positive for the first 10 slices (sensitivity = 89.8%, NPV 88.2%), and 57 were positive for the first 20 slices (sensitivity = 96.6%, NPV 95.7%). The median number of levels required to cover the entire heart was 34, and 97.2% of cases were covered in 40 or fewer levels. The use of 20 slices for purposes of detecting CAC is a reasonable choice for the C-100 scanners, because this would be accomplished in a breath hold. When the first slice starts at the base of the right pulmonary artery, all patients with CAC were identified. The C-150 scanner with the ability to scan on each heartbeat would increase sensitivity and NPV by acquiring 30 to 40 slices in a single breath hold.</p>","PeriodicalId":79315,"journal":{"name":"American journal of cardiac imaging","volume":"10 4","pages":"235-8"},"PeriodicalIF":0.0000,"publicationDate":"1996-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparison of 10, 20, and 40 level electron beam computed tomography studies for coronary calcium.\",\"authors\":\"J P Shields,&nbsp;C H Mielke,&nbsp;P Watson,&nbsp;F Viren\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>There are increasing data to support the use of the electron beam computed tomography (EBCT) scanner for early detection of coronary artery disease (CAD). A negative scan essentially rules out significant disease. How many EBCT 3 mm contiguous slices are needed to cover the coronary circulation? To answer this question, 104 consecutive patients referred for EBCT scan for evaluation of coronary artery calcium (CAC) were asked to participate. The sensitivity and negative predictive value (NPV) of calcium scores for the first 10 slices and first 20 slices, the second 20 slices, and the total scan were recorded. Scores greater than one were regarded as positive. The number of levels required to cover the entire heart was also recorded. Fifty-nine patients (56.7%) had a positive calcium score for the total scan. Of these, 53 were positive for the first 10 slices (sensitivity = 89.8%, NPV 88.2%), and 57 were positive for the first 20 slices (sensitivity = 96.6%, NPV 95.7%). The median number of levels required to cover the entire heart was 34, and 97.2% of cases were covered in 40 or fewer levels. The use of 20 slices for purposes of detecting CAC is a reasonable choice for the C-100 scanners, because this would be accomplished in a breath hold. When the first slice starts at the base of the right pulmonary artery, all patients with CAC were identified. The C-150 scanner with the ability to scan on each heartbeat would increase sensitivity and NPV by acquiring 30 to 40 slices in a single breath hold.</p>\",\"PeriodicalId\":79315,\"journal\":{\"name\":\"American journal of cardiac imaging\",\"volume\":\"10 4\",\"pages\":\"235-8\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1996-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"American journal of cardiac imaging\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"American journal of cardiac imaging","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

越来越多的数据支持使用电子束计算机断层扫描(EBCT)扫描仪进行冠状动脉疾病(CAD)的早期检测。阴性扫描基本上排除了重大疾病。覆盖冠状动脉循环需要多少张EBCT 3毫米连续切片?为了回答这个问题,104名连续接受EBCT扫描以评估冠状动脉钙(CAC)的患者被要求参与。记录前10片、前20片、后20片及总扫描钙评分的敏感性和阴性预测值(NPV)。分数大于1被认为是积极的。覆盖整个心脏所需的层数也被记录下来。59例(56.7%)患者在总扫描中钙评分为阳性。其中53例前10片阳性(敏感性为89.8%,NPV为88.2%),57例前20片阳性(敏感性为96.6%,NPV为95.7%)。覆盖整个心脏所需的平均水平是34个,97.2%的病例覆盖了40个或更少的水平。对于C-100扫描仪来说,使用20个切片来检测CAC是一个合理的选择,因为这将在屏气中完成。当第一张切片从右肺动脉底部开始时,所有CAC患者都被确定。能够扫描每次心跳的C-150扫描仪将通过在一次屏气中获取30到40个切片来提高灵敏度和NPV。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Comparison of 10, 20, and 40 level electron beam computed tomography studies for coronary calcium.

There are increasing data to support the use of the electron beam computed tomography (EBCT) scanner for early detection of coronary artery disease (CAD). A negative scan essentially rules out significant disease. How many EBCT 3 mm contiguous slices are needed to cover the coronary circulation? To answer this question, 104 consecutive patients referred for EBCT scan for evaluation of coronary artery calcium (CAC) were asked to participate. The sensitivity and negative predictive value (NPV) of calcium scores for the first 10 slices and first 20 slices, the second 20 slices, and the total scan were recorded. Scores greater than one were regarded as positive. The number of levels required to cover the entire heart was also recorded. Fifty-nine patients (56.7%) had a positive calcium score for the total scan. Of these, 53 were positive for the first 10 slices (sensitivity = 89.8%, NPV 88.2%), and 57 were positive for the first 20 slices (sensitivity = 96.6%, NPV 95.7%). The median number of levels required to cover the entire heart was 34, and 97.2% of cases were covered in 40 or fewer levels. The use of 20 slices for purposes of detecting CAC is a reasonable choice for the C-100 scanners, because this would be accomplished in a breath hold. When the first slice starts at the base of the right pulmonary artery, all patients with CAC were identified. The C-150 scanner with the ability to scan on each heartbeat would increase sensitivity and NPV by acquiring 30 to 40 slices in a single breath hold.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Variability of a three-layered appearance in intravascular ultrasound coronary images: a comparison of morphometric measurements with four intravascular ultrasound systems. Contrast-enhanced radiographic computed tomographic findings in patients with straight back syndrome. Comparison of 10, 20, and 40 level electron beam computed tomography studies for coronary calcium. Variation of heart rate and electrocardiograph trigger interval during ultrafast computed tomography. Evaluation of reference systems for quantitative wall motion analysis from three-dimensional endocardial surface reconstruction: an echocardiographic study in subjects with and without myocardial infarction.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1