产时反射式脉搏血氧测定:传感器位置和固定时间对血氧饱和度读数的影响。

K Faisst, P Kirkinen, V König, A Huch, R Huch
{"title":"产时反射式脉搏血氧测定:传感器位置和固定时间对血氧饱和度读数的影响。","authors":"K Faisst,&nbsp;P Kirkinen,&nbsp;V König,&nbsp;A Huch,&nbsp;R Huch","doi":"10.1023/a:1007472609561","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To determine the effects of sensor location and suction fixation duration on measurements of intrapartum fetal oxygen saturation (SpO2) with a new reflectance pulse oximetry system.</p><p><strong>Design: </strong>Fetal SpO2 values (n = 18) were determined in the first stage of labor before and after moving the sensor to another part of the fetal head.</p><p><strong>Results: </strong>Mean fetal SpO2 values did not differ with sensor location (95% CI: -3.59 to 1.48). The duration of measurement period 1, before moving the sensor, was 104 +/- 44 (range 30-240) min. No time-dependent changes in SpO2 values were seen (r = 0.17).</p><p><strong>Conclusion: </strong>Suction is an effective and noninvasive method of securing the reflectance pulse oximetry sensor to the fetal head in the first stage of labor and does not interfere with reproducible SpO2 values over several hours.</p>","PeriodicalId":77199,"journal":{"name":"Journal of clinical monitoring","volume":"13 5","pages":"299-302"},"PeriodicalIF":0.0000,"publicationDate":"1997-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1023/a:1007472609561","citationCount":"7","resultStr":"{\"title\":\"Intrapartum reflectance pulse oximetry: effects of sensor location and fixation duration on oxygen saturation readings.\",\"authors\":\"K Faisst,&nbsp;P Kirkinen,&nbsp;V König,&nbsp;A Huch,&nbsp;R Huch\",\"doi\":\"10.1023/a:1007472609561\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>To determine the effects of sensor location and suction fixation duration on measurements of intrapartum fetal oxygen saturation (SpO2) with a new reflectance pulse oximetry system.</p><p><strong>Design: </strong>Fetal SpO2 values (n = 18) were determined in the first stage of labor before and after moving the sensor to another part of the fetal head.</p><p><strong>Results: </strong>Mean fetal SpO2 values did not differ with sensor location (95% CI: -3.59 to 1.48). The duration of measurement period 1, before moving the sensor, was 104 +/- 44 (range 30-240) min. No time-dependent changes in SpO2 values were seen (r = 0.17).</p><p><strong>Conclusion: </strong>Suction is an effective and noninvasive method of securing the reflectance pulse oximetry sensor to the fetal head in the first stage of labor and does not interfere with reproducible SpO2 values over several hours.</p>\",\"PeriodicalId\":77199,\"journal\":{\"name\":\"Journal of clinical monitoring\",\"volume\":\"13 5\",\"pages\":\"299-302\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1997-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1023/a:1007472609561\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of clinical monitoring\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1023/a:1007472609561\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of clinical monitoring","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1023/a:1007472609561","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

目的:探讨新型反射式脉搏血氧仪传感器位置和吸力固定时间对胎儿产时血氧饱和度(SpO2)测定的影响。设计:胎儿SpO2值(n = 18)在分娩第一阶段将传感器移动到胎儿头部的另一部分之前和之后测定。结果:胎儿平均SpO2值与传感器位置没有差异(95% CI: -3.59至1.48)。在移动传感器之前,测量周期1的持续时间为104 +/- 44(范围30-240)min。SpO2值没有随时间变化(r = 0.17)。结论:在分娩第一阶段,吸痰是一种有效且无创的将反射式脉搏血氧仪传感器固定在胎儿头部的方法,并且在数小时内不会干扰SpO2值的再现。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Intrapartum reflectance pulse oximetry: effects of sensor location and fixation duration on oxygen saturation readings.

Objective: To determine the effects of sensor location and suction fixation duration on measurements of intrapartum fetal oxygen saturation (SpO2) with a new reflectance pulse oximetry system.

Design: Fetal SpO2 values (n = 18) were determined in the first stage of labor before and after moving the sensor to another part of the fetal head.

Results: Mean fetal SpO2 values did not differ with sensor location (95% CI: -3.59 to 1.48). The duration of measurement period 1, before moving the sensor, was 104 +/- 44 (range 30-240) min. No time-dependent changes in SpO2 values were seen (r = 0.17).

Conclusion: Suction is an effective and noninvasive method of securing the reflectance pulse oximetry sensor to the fetal head in the first stage of labor and does not interfere with reproducible SpO2 values over several hours.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Thanks to reviewers Pulse oximetry. Abstracts of scientific papers third international symposium on computing in anesthesia Abstracts of scientific papers computers in anesthesia VI Monitoring in Anesthesia, Second Edition
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1