单次扫描P300时潜伏期峰生理变异性的估计

Shigeto Nishida , Masatoshi Nakamura , Shugo Suwazono , Manabu Honda , Hiroshi Shibasaki
{"title":"单次扫描P300时潜伏期峰生理变异性的估计","authors":"Shigeto Nishida ,&nbsp;Masatoshi Nakamura ,&nbsp;Shugo Suwazono ,&nbsp;Manabu Honda ,&nbsp;Hiroshi Shibasaki","doi":"10.1016/S0168-5597(97)00048-8","DOIUrl":null,"url":null,"abstract":"<div><p>Among single sweep records of event-related potentials (ERPs), the peak latency of P300, which is one of the most prominent positive peaks in the ERP obtained in the oddball paradigm, may vary depending on the conditions of the subject. In the analysis of characteristics of the variability in the peak latency, it is important to know to what extent the variability of the measured peak latency (measured variability) is actually caused by physiological factors (physiological variability). In our previous study, a method was developed for judging whether the physiological variability really exists or not, and if it does exist, the developed method extracts the physiological variability from the measured variability based on a limited number of single sweep records. In the present study, based on the P300 waveforms which were detected by blinded visual inspection of the ERP data obtained by an auditory oddball paradigm from 12 healthy adults, the physiological variability was shown to exist with a confidence level of 95% for all subjects. Furthermore, its interval estimate was calculated by subtracting noise variability from the measured variability with a confidence level of 80%, and it was found to range from 17 to 57 ms for all subjects.</p></div>","PeriodicalId":100401,"journal":{"name":"Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section","volume":"104 5","pages":"Pages 431-436"},"PeriodicalIF":0.0000,"publicationDate":"1997-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0168-5597(97)00048-8","citationCount":"17","resultStr":"{\"title\":\"Estimate of physiological variability of peak latency in single sweep P300\",\"authors\":\"Shigeto Nishida ,&nbsp;Masatoshi Nakamura ,&nbsp;Shugo Suwazono ,&nbsp;Manabu Honda ,&nbsp;Hiroshi Shibasaki\",\"doi\":\"10.1016/S0168-5597(97)00048-8\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Among single sweep records of event-related potentials (ERPs), the peak latency of P300, which is one of the most prominent positive peaks in the ERP obtained in the oddball paradigm, may vary depending on the conditions of the subject. In the analysis of characteristics of the variability in the peak latency, it is important to know to what extent the variability of the measured peak latency (measured variability) is actually caused by physiological factors (physiological variability). In our previous study, a method was developed for judging whether the physiological variability really exists or not, and if it does exist, the developed method extracts the physiological variability from the measured variability based on a limited number of single sweep records. In the present study, based on the P300 waveforms which were detected by blinded visual inspection of the ERP data obtained by an auditory oddball paradigm from 12 healthy adults, the physiological variability was shown to exist with a confidence level of 95% for all subjects. Furthermore, its interval estimate was calculated by subtracting noise variability from the measured variability with a confidence level of 80%, and it was found to range from 17 to 57 ms for all subjects.</p></div>\",\"PeriodicalId\":100401,\"journal\":{\"name\":\"Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section\",\"volume\":\"104 5\",\"pages\":\"Pages 431-436\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1997-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/S0168-5597(97)00048-8\",\"citationCount\":\"17\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0168559797000488\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0168559797000488","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 17

摘要

在事件相关电位单次扫描记录中,P300的潜伏期峰值可能随被试的情况而变化,而P300是古怪范式下获得的事件相关电位最显著的正峰之一。在分析峰潜伏期变异性的特征时,重要的是要知道被测峰潜伏期的变异性(被测变异性)在多大程度上实际上是由生理因素(生理变异性)引起的。在我们之前的研究中,开发了一种判断生理变异性是否存在的方法,如果存在,该方法基于有限数量的单次扫描记录,从测量的变异性中提取生理变异性。在本研究中,基于盲法视觉检查12名健康成人的ERP数据(由听觉怪异范式获得)的P300波形,所有受试者的生理变异性均存在,置信水平为95%。此外,以80%的置信水平从测量的变异性中减去噪声变异性来计算其区间估计值,发现所有受试者的范围为17至57 ms。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Estimate of physiological variability of peak latency in single sweep P300

Among single sweep records of event-related potentials (ERPs), the peak latency of P300, which is one of the most prominent positive peaks in the ERP obtained in the oddball paradigm, may vary depending on the conditions of the subject. In the analysis of characteristics of the variability in the peak latency, it is important to know to what extent the variability of the measured peak latency (measured variability) is actually caused by physiological factors (physiological variability). In our previous study, a method was developed for judging whether the physiological variability really exists or not, and if it does exist, the developed method extracts the physiological variability from the measured variability based on a limited number of single sweep records. In the present study, based on the P300 waveforms which were detected by blinded visual inspection of the ERP data obtained by an auditory oddball paradigm from 12 healthy adults, the physiological variability was shown to exist with a confidence level of 95% for all subjects. Furthermore, its interval estimate was calculated by subtracting noise variability from the measured variability with a confidence level of 80%, and it was found to range from 17 to 57 ms for all subjects.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Visual Evoked Potentials Clinical Evoked Potentials: An Illustrated Manual Somatosensory Evoked Potentials Motor Evoked Potentials Cochlear implant performance and electrically-evoked auditory brain-stem response characteristics
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1