{"title":"[心脏手术后患者雾化氧下FiO2面罩的监测]。","authors":"L F Guo, J H Ma, B Guo","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Using Oxygen-Meter measure FiO2 directly inside the patient's mask in different oxygen flow. The purpose was to realize the actual FiO2 that patient inspirated. So oxygen therapy can be carried on correctly and scientifically and provide basis for respiratory monitoring and management post heart surgery. When patient breathe in oxygen in mask nebulize way, a porbe of oxygen meter was put in through a side hole 10 minutes later, the result was recorded. It demonstrated that when oxygen flow was 5L/min FiO2 inside mask was 56% approximately 58%. That means it's not correct to determine FiO2 according to the oxygen flow meter. The oxygen-meter should be used to monitor in order to avoid complications caused by incorrect adjustment and ensure the post heart surgery patient to recovery quickly.</p>","PeriodicalId":68372,"journal":{"name":"中华护理杂志","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1997-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Monitoring of FiO2 mask under nebulized oxygen therapy for post-heart surgery patients].\",\"authors\":\"L F Guo, J H Ma, B Guo\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Using Oxygen-Meter measure FiO2 directly inside the patient's mask in different oxygen flow. The purpose was to realize the actual FiO2 that patient inspirated. So oxygen therapy can be carried on correctly and scientifically and provide basis for respiratory monitoring and management post heart surgery. When patient breathe in oxygen in mask nebulize way, a porbe of oxygen meter was put in through a side hole 10 minutes later, the result was recorded. It demonstrated that when oxygen flow was 5L/min FiO2 inside mask was 56% approximately 58%. That means it's not correct to determine FiO2 according to the oxygen flow meter. The oxygen-meter should be used to monitor in order to avoid complications caused by incorrect adjustment and ensure the post heart surgery patient to recovery quickly.</p>\",\"PeriodicalId\":68372,\"journal\":{\"name\":\"中华护理杂志\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1997-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"中华护理杂志\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"中华护理杂志","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
[Monitoring of FiO2 mask under nebulized oxygen therapy for post-heart surgery patients].
Using Oxygen-Meter measure FiO2 directly inside the patient's mask in different oxygen flow. The purpose was to realize the actual FiO2 that patient inspirated. So oxygen therapy can be carried on correctly and scientifically and provide basis for respiratory monitoring and management post heart surgery. When patient breathe in oxygen in mask nebulize way, a porbe of oxygen meter was put in through a side hole 10 minutes later, the result was recorded. It demonstrated that when oxygen flow was 5L/min FiO2 inside mask was 56% approximately 58%. That means it's not correct to determine FiO2 according to the oxygen flow meter. The oxygen-meter should be used to monitor in order to avoid complications caused by incorrect adjustment and ensure the post heart surgery patient to recovery quickly.
期刊介绍:
Chinese Journal of Nursing was established on May 1, 1954. It is the earliest and oldest comprehensive nursing academic journal in China. Supervised by China Association for Science and Technology, sponsored by the Chinese Nursing Association and published at home and abroad, Chinese Journal of Nursing mainly reports the leading scientific research achievements and clinical experience in the field of nursing science, as well as the nursing theory research that has a guiding effect on nursing practice.
Included database
This journal has been included by China Science Citation Database (CSCD), SinoMed, China National Knowledge Infrastructure (CNKI), Wanfang Data Knowledge Service Platform, VIP Journal Resource Integration Service Platform and other Chinese platforms. It carries out academic exchanges with China Science and Technology information - Outstanding S&T Journals of China (F5000), CNKI Journal Translation Project,et,al. This journal has been included in Dimensions, WHO COVID-19 database and other international databases, among which the articles published in 1982-1997 are included in PMC and PubMed databases.
Honors
Top 100 Chinese Outstanding Academic Journals in 2020
The 5th China Excellent Science and Technology Journal
The 5th Publishing Government Award of Journal Nomination Award