{"title":"人类的光和血浆褪黑素节律。","authors":"K Honma, S Hashimoto, T Endo, S Honma","doi":"10.1159/000109142","DOIUrl":null,"url":null,"abstract":"<p><p>Plasma melatonin rhythm in humans was investigated: its stability, relationship to the sleep-wake rhythm, and response to light. The so-called day-to-day variation of reference phases of plasma melatonin rhythm was within 1.4 h when blood was sampled at 1-hour intervals. Therefore, a change in phase beyond this value is regarded as a phase shift of melatonin rhythm in individuals. Plasma melatonin rhythm was spontaneously desynchronized from the sleep-wake rhythm and probably regulated by the common circadian pacemaker which drives the rhythm in rectal temperature. When a bright-light pulse was applied, the melatonin rhythm produced a phase shift, but the amount of phase shift seems to be different for the ascending and descending phases of nocturnal melatonin rise. Finally, a partial entrainment was observed in a subject who developed a non-24-hour sleep-wake syndrome later, in which the plasma melatonin rhythm was free-running whereas the sleep-wake rhythm was apparently entrained by a 24-hour day-night alternation. It is concluded that the plasma melatonin rhythm is the best marker of the human circadian pacemaker so far available.</p>","PeriodicalId":9265,"journal":{"name":"Biological signals","volume":"6 4-6","pages":"307-12"},"PeriodicalIF":0.0000,"publicationDate":"1997-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1159/000109142","citationCount":"25","resultStr":"{\"title\":\"Light and plasma melatonin rhythm in humans.\",\"authors\":\"K Honma, S Hashimoto, T Endo, S Honma\",\"doi\":\"10.1159/000109142\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Plasma melatonin rhythm in humans was investigated: its stability, relationship to the sleep-wake rhythm, and response to light. The so-called day-to-day variation of reference phases of plasma melatonin rhythm was within 1.4 h when blood was sampled at 1-hour intervals. Therefore, a change in phase beyond this value is regarded as a phase shift of melatonin rhythm in individuals. Plasma melatonin rhythm was spontaneously desynchronized from the sleep-wake rhythm and probably regulated by the common circadian pacemaker which drives the rhythm in rectal temperature. When a bright-light pulse was applied, the melatonin rhythm produced a phase shift, but the amount of phase shift seems to be different for the ascending and descending phases of nocturnal melatonin rise. Finally, a partial entrainment was observed in a subject who developed a non-24-hour sleep-wake syndrome later, in which the plasma melatonin rhythm was free-running whereas the sleep-wake rhythm was apparently entrained by a 24-hour day-night alternation. It is concluded that the plasma melatonin rhythm is the best marker of the human circadian pacemaker so far available.</p>\",\"PeriodicalId\":9265,\"journal\":{\"name\":\"Biological signals\",\"volume\":\"6 4-6\",\"pages\":\"307-12\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1997-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1159/000109142\",\"citationCount\":\"25\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biological signals\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1159/000109142\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biological signals","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1159/000109142","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Plasma melatonin rhythm in humans was investigated: its stability, relationship to the sleep-wake rhythm, and response to light. The so-called day-to-day variation of reference phases of plasma melatonin rhythm was within 1.4 h when blood was sampled at 1-hour intervals. Therefore, a change in phase beyond this value is regarded as a phase shift of melatonin rhythm in individuals. Plasma melatonin rhythm was spontaneously desynchronized from the sleep-wake rhythm and probably regulated by the common circadian pacemaker which drives the rhythm in rectal temperature. When a bright-light pulse was applied, the melatonin rhythm produced a phase shift, but the amount of phase shift seems to be different for the ascending and descending phases of nocturnal melatonin rise. Finally, a partial entrainment was observed in a subject who developed a non-24-hour sleep-wake syndrome later, in which the plasma melatonin rhythm was free-running whereas the sleep-wake rhythm was apparently entrained by a 24-hour day-night alternation. It is concluded that the plasma melatonin rhythm is the best marker of the human circadian pacemaker so far available.