J Görich, N Rilinger, J Söldner, S Krämer, K H Orend, A Schütz, R Sokiranski, M Bartel, L Sunder-Plassmann, R Scharrer-Pamler
{"title":"主动脉瘤的血管内修复:并发症的治疗。","authors":"J Görich, N Rilinger, J Söldner, S Krämer, K H Orend, A Schütz, R Sokiranski, M Bartel, L Sunder-Plassmann, R Scharrer-Pamler","doi":"10.1583/1074-6218(1999)006<0136:EROAAT>2.0.CO;2","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the use of interventional procedures for treating complications following endovascular repair of aortic aneurysms.</p><p><strong>Methods: </strong>Fifty-five patients (49 men; mean age 67.5 years) underwent endoluminal stent-graft repair of traumatic (n = 4) or arteriosclerotic (n = 51) aortic aneurysms in the thoracic (n = 3) or infrarenal (n = 52) aorta. Follow-up of therapeutic success included periodic clinical examination, angiography, and spiral computed tomography.</p><p><strong>Results: </strong>Discounting the 25 (45%) cases of postimplantation syndrome that did not require treatment, there were 22 complications observed in 20 (36%) patients over a mean 10-month follow-up (range 1 to 27). There were 2 transrenal endograft maldeployments, 1 case of twisted graft limbs, 2 access site problems (1 patient), 12 endoleaks (11 patients), 1 late graft limb thrombosis, 1 symptomatic internal iliac artery occlusion, 2 myocardial infarctions, and 1 transient psychosis. Seven (13%) patients did not undergo specific therapy, while 4 (7%) required operation (2 crossover bypass grafts, 1 suture revision, and 1 graft replacement). Among 9 (16%) patients treated with interventional techniques, 7 underwent percutaneous coil embolization for 8 endoleaks (7 successfully resolved). One late stent-graft disconnection required an additional stent-graft, and 1 of the 2 malpositioned endografts was repositioned. All patients remain alive with no increase in the diameter of the aneurysm in any patient.</p><p><strong>Conclusions: </strong>Technical problems resulting from the endovascular repair of aortic aneurysms often respond to interventional treatment.</p>","PeriodicalId":79443,"journal":{"name":"Journal of endovascular surgery : the official journal of the International Society for Endovascular Surgery","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1999-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"33","resultStr":"{\"title\":\"Endovascular repair of aortic aneurysms: treatment of complications.\",\"authors\":\"J Görich, N Rilinger, J Söldner, S Krämer, K H Orend, A Schütz, R Sokiranski, M Bartel, L Sunder-Plassmann, R Scharrer-Pamler\",\"doi\":\"10.1583/1074-6218(1999)006<0136:EROAAT>2.0.CO;2\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To evaluate the use of interventional procedures for treating complications following endovascular repair of aortic aneurysms.</p><p><strong>Methods: </strong>Fifty-five patients (49 men; mean age 67.5 years) underwent endoluminal stent-graft repair of traumatic (n = 4) or arteriosclerotic (n = 51) aortic aneurysms in the thoracic (n = 3) or infrarenal (n = 52) aorta. Follow-up of therapeutic success included periodic clinical examination, angiography, and spiral computed tomography.</p><p><strong>Results: </strong>Discounting the 25 (45%) cases of postimplantation syndrome that did not require treatment, there were 22 complications observed in 20 (36%) patients over a mean 10-month follow-up (range 1 to 27). There were 2 transrenal endograft maldeployments, 1 case of twisted graft limbs, 2 access site problems (1 patient), 12 endoleaks (11 patients), 1 late graft limb thrombosis, 1 symptomatic internal iliac artery occlusion, 2 myocardial infarctions, and 1 transient psychosis. Seven (13%) patients did not undergo specific therapy, while 4 (7%) required operation (2 crossover bypass grafts, 1 suture revision, and 1 graft replacement). Among 9 (16%) patients treated with interventional techniques, 7 underwent percutaneous coil embolization for 8 endoleaks (7 successfully resolved). One late stent-graft disconnection required an additional stent-graft, and 1 of the 2 malpositioned endografts was repositioned. All patients remain alive with no increase in the diameter of the aneurysm in any patient.</p><p><strong>Conclusions: </strong>Technical problems resulting from the endovascular repair of aortic aneurysms often respond to interventional treatment.</p>\",\"PeriodicalId\":79443,\"journal\":{\"name\":\"Journal of endovascular surgery : the official journal of the International Society for Endovascular Surgery\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"33\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of endovascular surgery : the official journal of the International Society for Endovascular Surgery\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1583/1074-6218(1999)006<0136:EROAAT>2.0.CO;2\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of endovascular surgery : the official journal of the International Society for Endovascular Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1583/1074-6218(1999)006<0136:EROAAT>2.0.CO;2","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Endovascular repair of aortic aneurysms: treatment of complications.
Purpose: To evaluate the use of interventional procedures for treating complications following endovascular repair of aortic aneurysms.
Methods: Fifty-five patients (49 men; mean age 67.5 years) underwent endoluminal stent-graft repair of traumatic (n = 4) or arteriosclerotic (n = 51) aortic aneurysms in the thoracic (n = 3) or infrarenal (n = 52) aorta. Follow-up of therapeutic success included periodic clinical examination, angiography, and spiral computed tomography.
Results: Discounting the 25 (45%) cases of postimplantation syndrome that did not require treatment, there were 22 complications observed in 20 (36%) patients over a mean 10-month follow-up (range 1 to 27). There were 2 transrenal endograft maldeployments, 1 case of twisted graft limbs, 2 access site problems (1 patient), 12 endoleaks (11 patients), 1 late graft limb thrombosis, 1 symptomatic internal iliac artery occlusion, 2 myocardial infarctions, and 1 transient psychosis. Seven (13%) patients did not undergo specific therapy, while 4 (7%) required operation (2 crossover bypass grafts, 1 suture revision, and 1 graft replacement). Among 9 (16%) patients treated with interventional techniques, 7 underwent percutaneous coil embolization for 8 endoleaks (7 successfully resolved). One late stent-graft disconnection required an additional stent-graft, and 1 of the 2 malpositioned endografts was repositioned. All patients remain alive with no increase in the diameter of the aneurysm in any patient.
Conclusions: Technical problems resulting from the endovascular repair of aortic aneurysms often respond to interventional treatment.