{"title":"非金属超声针尖对植入物表面的改变。","authors":"G M Bailey,&nbsp;J S Gardner,&nbsp;M H Day,&nbsp;B J Kovanda","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>This study evaluates surface alterations produced on various implant surfaces by an ultrasonic scaler fitted with a nonmetallic tip. Commercially pure titanium and titanium alloy abutments, plasma-coated implants, and hydroxyapatite-coated implants were contacted with the nonmetallic tip for 10 seconds and then evaluated for surface changes by SEM examination. The commercially pure titanium and titanium alloy surfaces showed negligible alterations from the control, thus indicating possible clinical use as a maintenance device. More severe changes were evidenced with the plasma- and hydroxyapatite-coated surfaces.</p>","PeriodicalId":76686,"journal":{"name":"The Journal of the Western Society of Periodontology/Periodontal abstracts","volume":"46 3","pages":"69-73"},"PeriodicalIF":0.0000,"publicationDate":"1998-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Implant surface alterations from a nonmetallic ultrasonic tip.\",\"authors\":\"G M Bailey,&nbsp;J S Gardner,&nbsp;M H Day,&nbsp;B J Kovanda\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This study evaluates surface alterations produced on various implant surfaces by an ultrasonic scaler fitted with a nonmetallic tip. Commercially pure titanium and titanium alloy abutments, plasma-coated implants, and hydroxyapatite-coated implants were contacted with the nonmetallic tip for 10 seconds and then evaluated for surface changes by SEM examination. The commercially pure titanium and titanium alloy surfaces showed negligible alterations from the control, thus indicating possible clinical use as a maintenance device. More severe changes were evidenced with the plasma- and hydroxyapatite-coated surfaces.</p>\",\"PeriodicalId\":76686,\"journal\":{\"name\":\"The Journal of the Western Society of Periodontology/Periodontal abstracts\",\"volume\":\"46 3\",\"pages\":\"69-73\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1998-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Journal of the Western Society of Periodontology/Periodontal abstracts\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of the Western Society of Periodontology/Periodontal abstracts","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本研究评估了用非金属尖端的超声波秤对不同种植体表面产生的表面变化。将商用纯钛和钛合金基台、等离子涂层种植体和羟基磷灰石涂层种植体与非金属尖端接触10秒,然后通过扫描电镜检查评估表面变化。商业纯钛和钛合金表面显示出与对照组相比可以忽略不计的变化,因此表明可能在临床使用作为维护装置。等离子体和羟基磷灰石涂层的表面表现出更严重的变化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Implant surface alterations from a nonmetallic ultrasonic tip.

This study evaluates surface alterations produced on various implant surfaces by an ultrasonic scaler fitted with a nonmetallic tip. Commercially pure titanium and titanium alloy abutments, plasma-coated implants, and hydroxyapatite-coated implants were contacted with the nonmetallic tip for 10 seconds and then evaluated for surface changes by SEM examination. The commercially pure titanium and titanium alloy surfaces showed negligible alterations from the control, thus indicating possible clinical use as a maintenance device. More severe changes were evidenced with the plasma- and hydroxyapatite-coated surfaces.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Periodontal probing. Hereditary gingival fibromatosis--review of the literature. Demineralized dentin matrix and bone graft: a review of literature. Black yeast in dental unit waterlines. II. Remediation project report. Review of the literature on sodium hypochlorite as a treatment modality in periodontal disease.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1